Does Shear Wave Elastography Provide Additional Value in the Evaluation of Thyroid Nodules That Are Suspicious for Malignancy?

被引:23
作者
Wang, Fen [1 ,2 ]
Chang, Cai [1 ,2 ]
Gao, Yi [1 ,2 ]
Chen, Ya Ling [1 ,2 ]
Chen, Min [1 ,2 ]
Feng, Li Qing [2 ,3 ]
机构
[1] Fudan Univ, Shanghai Med Coll, Shanghai Canc Ctr, Dept Ultrasonog, 270 Dongan Rd,Bldg 1,Room 310, Shanghai 200030, Peoples R China
[2] Fudan Univ, Shanghai Med Coll, Shanghai Canc Ctr, Dept Oncol, Shanghai, Peoples R China
[3] Fudan Univ, Shanghai Med Coll, Shanghai Canc Ctr, Dept Pathol, Shanghai, Peoples R China
关键词
head and neck ultrasound; shear wave elastography; thyroid nodule; ultrasonography; NEEDLE-ASPIRATION BIOPSY; REAL-TIME ELASTOGRAPHY; ULTRASOUND ELASTOGRAPHY; QUANTITATIVE ASSESSMENT; DIFFERENTIAL-DIAGNOSIS; BREAST-LESIONS; DATA SYSTEM; US; BENIGN; MODE;
D O I
10.7863/ultra.15.09009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-We aimed to determine whether the integration of shear wave elastography (SWE) with conventional ultrasonography (US) improves diagnostic performance for suspicious thyroid lesions. Methods-For 215 thyroid lesions in 185 patients classified as Thyroid Imaging Reporting and Data System category 4 or 5 according to the findings of conventional US, SWE elasticity indices were automatically calculated. A receiver operating characteristic curve analysis was used to determine the threshold. Thyroid Imaging Reporting and Data System categories were upgraded for high-stiffness nodules and unchanged for low-and normal-stiffness nodules. The diagnostic performances were assessed and compared with histologic findings. Intraobserver and interobserver variability of SWE was assessed. Results-Elasticity indices were significantly higher in malignant versus benign nodules (P <=.001). The minimum elasticity index (cutoff, 40.7 kPa) of the stiffest part combined with conventional US showed the highest area under the curve (0.774; 95% confidence interval, 0.682-0.866) but was not superior to conventional US (0.791; 95% confidence interval, 0.706-0.876; P=.48). Combined with the standard deviation of the elasticity index for the whole lesion (cutoff, 6.8 kPa), US yielded the highest sensitivity (95.5%; P<.001) and lowest specificity (42.1%; P<.001). Sensitivity increased and specificity decreased by adding any other SWE elasticity index. The intraobserver and interobserver reliability of SWE was fair to excellent according to the interclass correlation coefficients, with correlation coefficients of 0.765 to 0.846 (all P<.001). Conclusions-The SWE elasticity indices of malignant thyroid nodules were significantly high. Adding SWE to conventional US did not improve diagnostic performance.
引用
收藏
页码:2397 / 2404
页数:8
相关论文
共 32 条
  • [1] EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 1: Basic Principles and Technology
    Bamber, J.
    Cosgrove, D.
    Dietrich, C. F.
    Fromageau, J.
    Bojunga, J.
    Calliada, F.
    Cantisani, V.
    Correas, J. -M.
    D'Onofrio, M.
    Drakonaki, E. E.
    Fink, M.
    Friedrich-Rust, M.
    Gilja, O. H.
    Havre, R. F.
    Jenssen, C.
    Klauser, A. S.
    Ohlinger, R.
    Saftoiu, A.
    Schaefer, F.
    Sporea, I.
    Piscaglia, F.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2013, 34 (02): : 169 - 184
  • [2] Supersonic shear imaging: A new technique for soft tissue elasticity mapping
    Bercoff, J
    Tanter, M
    Fink, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) : 396 - 409
  • [3] Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 Masses
    Berg, Wendie A.
    Cosgrove, David O.
    Dore, Caroline J.
    Schaefer, Fritz K. W.
    Svensson, William E.
    Hooley, Regina J.
    Ohlinger, Ralf
    Mendelson, Ellen B.
    Balu-Maestro, Catherine
    Locatelli, Martina
    Tourasse, Christophe
    Cavanaugh, Barbara C.
    Juhan, Valerie
    Stavros, A. Thomas
    Tardivon, Anne
    Gay, Joel
    Henry, Jean-Pierre
    Cohen-Bacrie, Claude
    [J]. RADIOLOGY, 2012, 262 (02) : 435 - 449
  • [4] Cystic change in thyroid nodules: A confounding factor for real-time qualitative thyroid ultrasound elastography
    Bhatia, K. S. S.
    Rasalkar, D. P.
    Lee, Y. P.
    Wong, K. T.
    King, A. D.
    Yuen, H. Y.
    Ahuja, A. T.
    [J]. CLINICAL RADIOLOGY, 2011, 66 (09) : 799 - 807
  • [5] Shear wave elastography of thyroid nodules in routine clinical practice: preliminary observations and utility for detecting malignancy
    Bhatia, Kunwar S. S.
    Tong, Cina S. L.
    Cho, Carmen C. M.
    Yuen, Edmund H. Y.
    Lee, Yolanda Y. P.
    Ahuja, Anil T.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (11) : 2397 - 2406
  • [6] Real-Time Elastography for the Differentiation of Benign and Malignant Thyroid Nodules: A Meta-Analysis
    Bojunga, Joerg
    Herrmann, Eva
    Meyer, Gesine
    Weber, Sonja
    Zeuzem, Stefan
    Friedrich-Rust, Mireen
    [J]. THYROID, 2010, 20 (10) : 1145 - 1150
  • [7] Continuing controversies in the management of thyroid nodules
    Castro, MR
    Gharib, H
    [J]. ANNALS OF INTERNAL MEDICINE, 2005, 142 (11) : 926 - 931
  • [8] Management of thyroid nodules detected at US: Society of Radiologists in Ultrasound consensus conference statement
    Frates, MC
    Benson, CB
    Charboneau, JW
    Cibas, ES
    Clark, OH
    Coleman, BG
    Cronan, JJ
    Doubilet, PM
    Evans, DB
    Goellner, JR
    Hay, ID
    Hertzberg, BS
    Intenzo, CM
    Jeffrey, RB
    Langer, JE
    Larsen, PR
    Mandel, SJ
    Middleton, WD
    Reading, CC
    Sherman, SI
    Tessier, FN
    [J]. RADIOLOGY, 2005, 237 (03) : 794 - 800
  • [9] An Ultrasonogram Reporting System for Thyroid Nodules Stratifying Cancer Risk for Clinical Management
    Horvath, Eleonora
    Majlis, Sergio
    Rossi, Ricardo
    Franco, Carmen
    Niedmann, Juan P.
    Castro, Alex
    Dominguez, Miguel
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2009, 94 (05) : 1748 - 1751
  • [10] Quantitative assessment of shear-wave ultrasound elastography in thyroid nodules: diagnostic performance for predicting malignancy
    Kim, Hana
    Kim, Jeong-Ah
    Son, Eun Ju
    Youk, Ji Hyun
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (09) : 2532 - 2537