Failure Assessment of Lightly Reinforced Floor Slabs. I: Experimental Investigation

被引:21
作者
Cashell, K. A. [1 ]
Elghazouli, A. Y. [2 ]
Izzuddin, B. A. [2 ]
机构
[1] Steel Construct Inst, Ascot SL5 7QN, Berks, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Civil & Environm Engn, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
Composite steel/concrete; Composite slabs; Lightly reinforced members; Failure conditions; Ductility; Reinforcement fracture; MEMBRANE ACTION; COMPOSITE; FIRE;
D O I
10.1061/(ASCE)ST.1943-541X.0000420
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is concerned with the ultimate behavior of lightly reinforced concrete floor slabs under extreme loading conditions. Particular emphasis is given to examining the failure conditions of idealized composite slabs which become lightly reinforced in a fire situation as a result of the early loss of the steel deck. An experimental study is described which focuses on the response of two-way spanning floor slabs with various materials and geometric configurations. The tests enable direct assessment of the influence of a number of key parameters such as the reinforcement type, properties, and ratio on the ultimate response. The results also permit the development of simplified expressions that capture the influence of salient factors such as bond characteristics and reinforcement properties for predicting the ductility of lightly reinforced floor slabs. The companion paper complements the experimental observations with detailed numerical assessments of the ultimate response and proposes analytical models that predict failure of slab members by either reinforcement fracture or compressive crushing of concrete. DOI: 10.1061/(ASCE)ST.1943-541X.0000420. (C) 2011 American Society of Civil Engineers.
引用
收藏
页码:977 / 988
页数:12
相关论文
共 20 条
[1]  
[Anonymous], THESIS IMPERIAL COLL
[2]  
Bailey C.G., 2000, STRUCT ENG, V78, P19
[3]  
Bailey C.G., 2000, STRUCT ENG, V78, P28
[4]   The tensile membrane action of unrestrained composite slabs simulated under fire conditions [J].
Bailey, CG ;
White, DS ;
Moore, DB .
ENGINEERING STRUCTURES, 2000, 22 (12) :1583-1595
[5]   Membrane action of slab/beam composite floor systems in fire [J].
Bailey, CG .
ENGINEERING STRUCTURES, 2004, 26 (12) :1691-1703
[6]   Small-scale concrete slab tests at ambient and elevated temperatures [J].
Bailey, Colin G. ;
Toh, Wee Siang .
ENGINEERING STRUCTURES, 2007, 29 (10) :2775-2791
[7]  
BROTCHIE JF, 1971, PUBLICATION AM CONCR, P345
[8]   Failure Assessment of Lightly Reinforced Floor Slabs. II: Analytical Studies [J].
Cashell, K. A. ;
Elghazouli, A. Y. ;
Izzuddin, B. A. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2011, 137 (09) :989-1001
[9]   Experimental and analytical assessment of ductility in lightly reinforced concrete members [J].
Cashell, K. A. ;
Elghazouli, A. Y. ;
Izzuddin, B. A. .
ENGINEERING STRUCTURES, 2010, 32 (09) :2729-2743
[10]   Ultimate Behavior of Idealized Composite Floor Elements at Ambient and Elevated Temperature [J].
Cashell, K. A. ;
Elghazouli, A. Y. ;
Izzuddin, B. A. .
FIRE TECHNOLOGY, 2010, 46 (01) :67-89