Cost-effectiveness of capsule endoscopy in screening for colorectal cancer

被引:87
作者
Hassan, C. [1 ]
Zullo, A. [1 ]
Winn, S. [1 ]
Morini, S. [1 ]
机构
[1] Osped Nuovo Regina Margherita, Gastroenterol & Digest Endoscopy Unit, I-00153 Rome, Italy
关键词
D O I
10.1055/s-2007-995565
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: Capsule endoscopy (Pillcam Colon) has recently shown acceptable accuracy in detecting colonic lesions when compared with colonoscopy. The aim of this analysis is to provide a model to assess the cost and effectiveness of population-based screening for colorectal cancer (CRC) using capsule endoscopy and to compare the cost-effectiveness with that of a colonoscopy screening program. Methods: The cost-effectiveness of two screening strategies using colonoscopy or capsule endoscopy were compared by a computer model based on a Markov process. In this model, a hypothetical population of 100000 individuals aged 50 years and over, undergoes a 10 yearly screening procedure. Different thresholds for postcapsule polypectomy referral were simulated. Results: At baseline, the incremental cost-effectiveness (compared with no screening) of colonoscopy and capsule endoscopy was $16165 and $29244 per life-year saved, respectively. When equal compliance was simulated, the colonoscopy program was more effective and less costly than a strategy based on capsule endoscopy. When simulating an initial compliance to capsule endoscopy 30% better than colonoscopy, capsule endoscopy became the more effective and more cost-effective option. A 20% better compliance was sufficient when a higher accuracy of capsule endoscopy for polyps was assumed. A 6 mm threshold for polypectomy referral was associated with a substantial cost reduction in the capsule endoscopy program with only a small loss of efficacy. Conclusions: The cost-effectiveness of capsule endoscopy depends mainly on its ability to improve compliance to CRC screening.
引用
收藏
页码:414 / 421
页数:8
相关论文
共 63 条
[41]   Cost-effectiveness analyses of colorectal cancer screening: A systematic review for the US preventive services task force [J].
Pignone, M ;
Saha, S ;
Hoerger, T ;
Mandelblatt, J .
ANNALS OF INTERNAL MEDICINE, 2002, 137 (02) :96-104
[42]   Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies [J].
Rex, DK ;
Cutler, CS ;
Lemmel, GT ;
Rahmani, EY ;
Clark, DW ;
Helper, DJ ;
Lehman, GA ;
Mark, DG .
GASTROENTEROLOGY, 1997, 112 (01) :24-28
[43]  
RICKERT RR, 1979, CANCER-AM CANCER SOC, V43, P1847, DOI 10.1002/1097-0142(197905)43:5<1847::AID-CNCR2820430538>3.0.CO
[44]  
2-L
[45]  
RIES LA, 1997, NIH PUBLICATION, P117
[46]  
Ries LAG, 2000, CANCER-AM CANCER SOC, V88, P2398, DOI 10.1002/(SICI)1097-0142(20000515)88:10<2398::AID-CNCR26>3.0.CO
[47]  
2-I
[48]   PillCam colon capsule endoscopy compared with colonoscopy for colorectal tumor diagnosis:: a prospective pilot study [J].
Schoofs, N. ;
Deviere, J. ;
Van Gossum, A. .
ENDOSCOPY, 2006, 38 (10) :971-977
[49]  
SCHOOFS N, 2007, GUT, V56, pA71
[50]  
SEARE S, 1997, DRG GUIDE