Splice strength of large diameter, high strength steel reinforcing bars

被引:12
|
作者
Hassan, Tarek K. [1 ]
Lucier, Gregory W. [2 ]
Rizkalla, Sami H. [2 ]
机构
[1] Ain Shams University, Structural Engineering Dept, Cairo, Egypt
[2] NCSU, Dept Civil Construct & Environm Engn, Raleigh, NC USA
基金
美国国家科学基金会;
关键词
Beams; Bond; Concrete; Confinement; Development length; High strength reinforcement; Splice strength; DEVELOPMENT LENGTH; CONCRETE;
D O I
10.1016/j.conbuildmat.2011.06.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The results of an experimental program conducted to study the splice strength of large diameter, high strength reinforcing bars, either No. 20 (63.5 mm diameter) or No. 9 (28 mm diameter), are presented. The parameters included in the experimental program are the bar size, splice length, concrete compressive strength, and the amount of transverse reinforcement provided within the splice zone. The ability of several models including the current ACI 318 Building Code, to predict the maximum steel stresses at the onset of splitting failure was examined for these high strength, large diameter bars. The influence of the moment of inertia of the bar on the induced splitting stresses was evaluated numerically using finite element analysis. Test results showed that the presence of transverse reinforcement has a more pronounced effect for large diameter spliced-bars compared to regular size bars. It is also shown that the current ACI 318 Building Code provided more conservative bond strength predictions for regular bars compared to large diameter bars. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:216 / 225
页数:10
相关论文
共 50 条