Evaluation of the Quantitative Gated SPECT (QGS) software program in the presence of large perfusion defects

被引:14
作者
America, YGCJ
Bax, JJ
Dibbets-Schneider, P
Pauwels, EKJ
van der Wall, EE
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Radiol, Div Nucl Med, NL-2300 RC Leiden, Netherlands
关键词
Cedars-Sinai's Quantitative SPECT (QGS) software; operator dependence; reproducibility;
D O I
10.1007/s10554-005-0274-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To evaluate the reproducibility and operator dependence for the quantitative regional left ventricular functional parameters (LVFP) assessed by Cedars-Sinai's Quantitative automated gated SPECT (QGS) software. Methods: The QGS algorithm was reviewed in detail and potential operator dependencies were defined. Series of prototypes were selected, consisting of (a) normal perfusion, (b) perfusion defects in all perfusion regions, (c) perfusion studies of patients with angiographic confirmed normal coronary arteries, proximal (>= 70% stenoses) single and multiple vessel disease, and (d) spurious activity in close proximity. While defining and re-orienting the volume containing the left ventricle, the operator adjusted 8 variables/degrees of freedom (DF). The software was used without further operator interventions. Results were expressed as a coefficient of variation (COV). Separate COV were calculated per distinct DF. A segment was considered not robust when the COV did exceed 20% in a single DF, 15% in at least 2 DF, or 10% in at least 3 DF. Results: Regional left ventricular EF and volumes showed excellent reproducibility. Normal perfusion and the vessel disease prototypes showed an excellent COV (for all re-orientation steps [33/prototype]) mostly below 5% for LVFP. However, regional wall motion and thickening became less reliable in the presence of large perfusion defects or artifacts. Conclusions: Quantitative estimates for regional left ventricular functional data show excellent reproducibility using automated gated SPECT. However, there may be substantial operator dependency in the presence of large defects or spurious activity in close proximity.
引用
收藏
页码:519 / 529
页数:11
相关论文
共 23 条
[1]   Thallium-201 gated single-photon emission tomography for the assessment of left ventricular ejection fraction and regional wall motion abnormalities in comparison with two-dimensional echocardiography [J].
Bacher-Stier, C ;
Müller, S ;
Pachinger, O ;
Strolz, S ;
Erler, H ;
Moncayo, R ;
Wenger, M ;
Donnemiller, E ;
Riccabona, G .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (12) :1533-1540
[2]   Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation [J].
Berman, DS ;
Abidov, A ;
Kang, XP ;
Hayes, SW ;
Friedman, JD ;
Sciammarella, MG ;
Cohen, I ;
Gerlach, J ;
Waechter, PB ;
Germano, G ;
Hachamovitch, R .
JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (04) :414-423
[3]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[4]   GATED TC-99M SESTAMIBI FOR SIMULTANEOUS ASSESSMENT OF STRESS MYOCARDIAL PERFUSION, POSTEXERCISE REGIONAL VENTRICULAR-FUNCTION AND MYOCARDIAL VIABILITY - CORRELATION WITH ECHOCARDIOGRAPHY AND REST TL-201 SCINTIGRAPHY [J].
CHUA, T ;
KIAT, H ;
GERMANO, G ;
MAURER, G ;
VANTRAIN, K ;
FRIEDMAN, J ;
BERMAN, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) :1107-1114
[5]   Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: Correlation with equilibrium radionuclide ventriculography and echocardiography [J].
Chua, T ;
Yin, LC ;
Thiang, TH ;
Choo, TB ;
Ping, DZ ;
Leng, LY .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (04) :301-311
[6]   Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods [J].
Faber, TL ;
Vansant, JP ;
Pettigrew, RI ;
Galt, JR ;
Blais, M ;
Chatzimavroudis, G ;
Cooke, CD ;
Folks, RD ;
Waldrop, SM ;
Gurtler-Krawczynska, E ;
Wittry, MD ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) :645-651
[7]  
Germano G, 1997, J NUCL MED, V38, P749
[8]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[9]  
Germano G, 2000, J NUCL MED, V41, P712
[10]   Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography [J].
Germano, G ;
Erel, J ;
Lewin, H ;
Kavanagh, PB ;
Berman, DS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (05) :1360-1367