Consistency of open-loop experimental frequency-response data with coprime factor plant models

被引:23
|
作者
Boulet, B [1 ]
Francis, BA
机构
[1] McGill Univ, Dept Elect & Comp Engn, Syst & Control Grp, Montreal, PQ H3A 2A7, Canada
[2] McGill Univ, Ctr Intelligent Machines, Montreal, PQ H3A 2A7, Canada
[3] Univ Toronto, Dept Elect & Comp Engn, Syst Control Grp, Toronto, ON M5S 1A4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
coprime factorization; model validation; Nevanlinna-Pick interpolation; robustness; uncertain systems;
D O I
10.1109/9.736064
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The model/data consistency problem for coprime factorizations considered here is this: Given some possibly noisy frequency-response data obtained by running open-loop experiments on a system, show that these data are consistent with a given family of perturbed coprime factor models and a time-domain L-infinity noise model. In the noise-free open-loop case, the model/data consistency problem boils down to the existence of an interpolating function in RHinfinity that evaluates to a finite number of complex matrices at a finite number of points on the imaginary axis. A theorem on boundary interpolation in RHinfinity is a building block that allows us to devise computationally simple necessary and sufficient tests to check if the perturbed coprime factorization is consistent with the data. For standard coprime factorizations, the test involves the computation of minimum-norm solutions to underdetermined complex matrix equations. The Schmidt-Mirsky theorem is used in the case of special factorizations of flexible systems. For L-infinity noise corrupting the frequency-response measurements, a complete solution to the open-loop noisy single-input/single-output problem using the structured singular value mu is given.
引用
收藏
页码:1680 / 1691
页数:12
相关论文
共 34 条
  • [21] OPEN-LOOP CONTROL OF COMBUSTION INSTABILITIES AND THE ROLE OF THE FLAME RESPONSE TO TWO-FREQUENCY FORCING
    Cosic, Bernhard
    Bobusch, Bernhard C.
    Moeck, Jonas P.
    Paschereit, Christian Oliver
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 2, PTS A AND B, 2011, : 1205 - 1215
  • [22] Open-loop narrowband magnetic particle imaging based on mixed-frequency harmonic magnetization response
    Yu, Hongli
    Huang, Ping
    Peng, Xiting
    Wang, Zheyan
    Qiu, Zhichuan
    Li, Kewen
    Li, Tianshu
    Liu, Zhiyao
    Cui, Hao
    Bai, Shi
    FRONTIERS IN MEDICAL TECHNOLOGY, 2024, 6
  • [23] Carotid and aortic baroreflexes of the rat: II. Open-loop frequency response and the blood pressure spectrum
    Dworkin, BR
    Tang, XR
    Snyder, AJ
    Dworkin, S
    AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2000, 279 (05) : R1922 - R1933
  • [24] Hardware platforms for MEMS gyroscope tuning based on evolutionary computation using open-loop and closed-loop frequency response
    Keymeulen, D
    Ferguson, MI
    Fink, W
    Oks, B
    Peay, C
    Terrile, R
    Yen-Cheng
    Kim, D
    MacDonald, E
    Foor, D
    EVOLVABLE SYSTEMS: FROM BIOLOGY TO HARDWARE, 2005, 3637 : 215 - 226
  • [25] Open-loop frequency response analysis of a wind turbine using a high-order linear aeroelastic model
    Sonderby, Ivan
    Hansen, Morten H.
    WIND ENERGY, 2014, 17 (08) : 1147 - 1167
  • [26] Frequency response estimation for NCFs of an MIMO plant from closed-loop time-domain experimental data
    Zhou, T
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2006, 51 (01) : 38 - 51
  • [27] Experimental Determination of the Open Loop Frequency Response Function of a Hydraulic Servo-Cylinder.
    Mornas, J.P.
    1600, (19):
  • [28] Open-loop step responses for the MEA post-combustion capture process: Experimental results from the Esbjerg pilot plant.
    Faber, Richard
    Kopcke, Moritz
    Biede, Ole
    Knudsen, Jacob Nygaard
    Andersen, Jimmy
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1427 - 1434
  • [29] A new experimental approach in measuring open loop frequency response of isolated DC/DC-converters
    Semmler, P
    INTELEC 2001: TWENTY-THIRD INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 2001, (484): : 274 - 278
  • [30] Experimental results of transient testing at the amine plant at Technology Centre Mongstad: Open-loop responses and performance of decentralized control structures for load changes
    Montanes, Ruben M.
    Flo, Nina E.
    Nord, Lars O.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 73 : 42 - 59