Urea potentiometric enzymatic biosensor based on charged biopolymers and electrodeposited polyaniline

被引:80
作者
Lakard, Boris [1 ]
Magnin, Delphine [2 ]
Deschaume, Olivier [2 ]
Vanlancker, Guilhem [2 ]
Glinel, Marine [2 ]
Demoustier-Champagne, Sophie [2 ]
Nysten, Bernard [2 ]
Jonas, Alain M. [2 ]
Bertrand, Patrick [2 ]
Yunus, Sami [2 ]
机构
[1] Univ Franche Comte, Inst UTINAM, UMR CNRS 6213, Equipe Mat & Surfaces Struct, F-25030 Besancon, France
[2] Catholic Univ Louvain, Inst Condensed Matter & Nanosci, B-1348 Louvain, Belgium
关键词
Urea biosensor; Enzyme immobilization; Conducting polymer; Polyaniline; Polyelectrolyte multilayers; Polysaccharides; NANOPOROUS ALUMINA MEMBRANES; INTEGRATED THERMAL BIOSENSOR; ELECTROINACTIVE POLYPYRROLE; PH; IMMOBILIZATION; SURFACE; SENSOR; FILMS; TRANSDUCER; PENICILLIN;
D O I
10.1016/j.bios.2011.04.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric biosensor based on urease was developed for the quantitative determination of urea concentration in aqueous solutions for biomedical applications. The urease was either physisorbed onto an electrodeposited polyaniline film (PANE), or immobilized on a layer-by-layer film (LbL) assembled over the PANI film, that was obtained by the alternate deposition of charged polysaccharides (carboxymethylpullulan (CMP) and chitosan (CHI)). In the latter case, the urease (Urs) enzyme was either physically adsorbed or covalently grafted to the LbL film using carbodiimide coupling reaction. Potentiometric responses of the enzymatic biosensors were measured as a function of the urea concentration in aqueous solutions (from 10(-6) to 10(-1) mol L-1 urea). Very high sensitivity and short response time were observed for the present biosensor. Moreover, a stability study showed a higher stability over time for the potentiometric response of the sensor with the enzyme-grafted LbL film, testifying for the protective nature of the polysaccharide coating and the interest of covalent grafting. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4139 / 4145
页数:7
相关论文
共 50 条
  • [41] An enzymatic biosensor for hydrogen peroxide based on CeO2 nanostructure electrodeposited on ITO surface
    Yagati, Ajay Kumar
    Lee, Taek
    Min, Junhong
    Choi, Jeong-Woo
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 385 - 390
  • [42] Prussian blue based impedimetric urea biosensor
    Valiuniene, Ausra
    Kavaliauskaite, Gabija
    Virbickas, Povilas
    Ramanavicius, Arunas
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 895
  • [43] Sulfonated-polypyrene aniline/polyaniline composite fortified with Cu-GQD@ZIF8 as an electrochemical enzymatic urea biosensor
    Camurcu, Taskin
    Sanko, Vildan
    Omeroglu, Ipek
    Tumay, Sureyya Oguz
    Senocak, Ahmet
    ANALYTICAL METHODS, 2024, 16 (39) : 6696 - 6707
  • [44] Polyaniline/Prussian-Blue-Based Amperometric Biosensor for Detection of Uric Acid
    Thakur, Bhawana
    Sawant, Shilpa N.
    CHEMPLUSCHEM, 2013, 78 (02): : 166 - 174
  • [45] Potentiometric urea biosensor based on immobilization of urease onto molecularly imprinted TiO2 film
    Chen, Xin
    Yang, Zhengpeng
    Si, Shihui
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 635 (01) : 1 - 6
  • [46] Composite Material Based on Macroporous Polyaniline and Osmium Redox Complex for Biosensor Development
    Antiochia, Riccarda
    Mazzei, Franco
    Gorton, Lo
    Leech, Donal
    Favero, Gabriele
    ELECTROANALYSIS, 2014, 26 (07) : 1623 - 1630
  • [47] A facile and simple polyaniline-poly(ethylene oxide) based glucose biosensor
    Hansen, Betina
    Hocevar, Marcele A.
    Ferreira, Carlos A.
    SYNTHETIC METALS, 2016, 222 : 224 - 231
  • [48] A conductometric creatinine biosensor prepared through contact printing of polyvinyl alcohol/polyethyleneimine based enzymatic membrane
    Braiek, Mohamed
    Djebbi, Mohamed Amine
    Chateaux, Jean-Francois
    Bonhomme, Anne
    Vargiolu, Roberto
    Bessueille, Francois
    Jaffrezic-Renault, Nicole
    MICROELECTRONIC ENGINEERING, 2018, 187 : 43 - 49
  • [49] Development of potentiometric urea biosensor based on urease immobilized in PVA-PAA composite matrix for estimation of blood urea nitrogen (BUN)
    Jha, Sandeep Kumar
    Topkar, Anita
    D'Souza, Stanislaus F.
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2008, 70 (06): : 1145 - 1150
  • [50] Potentiometric biosensor for determination of urea in milk using immobilized Arthrobacter creatinolyticus urease
    Ramesh, Rajendran
    Puhazhendi, Puhazhselvan
    Kumar, Jitendra
    Gowthaman, Marichetti Kuppuswami
    D'Souza, Stanislaus Francis
    Kamini, Numbi Ramudu
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 786 - 792