Urea potentiometric enzymatic biosensor based on charged biopolymers and electrodeposited polyaniline

被引:80
作者
Lakard, Boris [1 ]
Magnin, Delphine [2 ]
Deschaume, Olivier [2 ]
Vanlancker, Guilhem [2 ]
Glinel, Marine [2 ]
Demoustier-Champagne, Sophie [2 ]
Nysten, Bernard [2 ]
Jonas, Alain M. [2 ]
Bertrand, Patrick [2 ]
Yunus, Sami [2 ]
机构
[1] Univ Franche Comte, Inst UTINAM, UMR CNRS 6213, Equipe Mat & Surfaces Struct, F-25030 Besancon, France
[2] Catholic Univ Louvain, Inst Condensed Matter & Nanosci, B-1348 Louvain, Belgium
关键词
Urea biosensor; Enzyme immobilization; Conducting polymer; Polyaniline; Polyelectrolyte multilayers; Polysaccharides; NANOPOROUS ALUMINA MEMBRANES; INTEGRATED THERMAL BIOSENSOR; ELECTROINACTIVE POLYPYRROLE; PH; IMMOBILIZATION; SURFACE; SENSOR; FILMS; TRANSDUCER; PENICILLIN;
D O I
10.1016/j.bios.2011.04.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric biosensor based on urease was developed for the quantitative determination of urea concentration in aqueous solutions for biomedical applications. The urease was either physisorbed onto an electrodeposited polyaniline film (PANE), or immobilized on a layer-by-layer film (LbL) assembled over the PANI film, that was obtained by the alternate deposition of charged polysaccharides (carboxymethylpullulan (CMP) and chitosan (CHI)). In the latter case, the urease (Urs) enzyme was either physically adsorbed or covalently grafted to the LbL film using carbodiimide coupling reaction. Potentiometric responses of the enzymatic biosensors were measured as a function of the urea concentration in aqueous solutions (from 10(-6) to 10(-1) mol L-1 urea). Very high sensitivity and short response time were observed for the present biosensor. Moreover, a stability study showed a higher stability over time for the potentiometric response of the sensor with the enzyme-grafted LbL film, testifying for the protective nature of the polysaccharide coating and the interest of covalent grafting. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4139 / 4145
页数:7
相关论文
共 50 条
  • [31] Fabrication, characterization of polyaniline intercalated NiO nanocomposites and application in the development of non-enzymatic glucose biosensor
    Azharudeen, A. Mohamed
    Karthiga, R.
    Rajarajan, M.
    Suganthi, A.
    ARABIAN JOURNAL OF CHEMISTRY, 2020, 13 (02) : 4053 - 4064
  • [32] ENZYME UREA BIOSENSOR BASED ON A MODIFIED POTENTIOMETRIC PVC-NONACTIN MEMBRANE-ELECTRODE FOR ASSAY OF UREA IN BLOOD
    BUTT, SB
    CAMMANN, K
    ANALYTICAL LETTERS, 1992, 25 (09) : 1597 - 1615
  • [33] Copper phthalocyanine-borophene nanocomposite-based non-enzymatic electrochemical urea biosensor
    Gungor, Saliha
    Tasaltin, Cihat
    Gurol, Ilke
    Baytemir, Gulsen
    Karakus, Selcan
    Tasaltin, Nevin
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2022, 128 (01):
  • [34] Polyaniline-based glucose biosensor: A review
    Lai, Jiahui
    Yi, Yingchun
    Zhu, Ping
    Shen, Jing
    Wu, Kesen
    Zhang, Lili
    Liu, Jian
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 782 : 138 - 153
  • [35] The Analysis of Potentiometric Flexible Arrayed Urea Biosensor Modified by Graphene Oxide and γ-Fe2O3 Nanoparticles
    Nien, Yu-Hsun
    Su, Tzu-Yu
    Ho, Chih-Sung
    Chou, Jung-Chuan
    Lai, Chih-Hsien
    Kuo, Po-Yu
    Kang, Zhi-Xuan
    Dong, Zhe-Xin
    Lai, Tsu-Yang
    Wang, Chu-Hsuan
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2020, 67 (11) : 5104 - 5110
  • [36] Urea impedimetric biosensor based on reactive RF magnetron sputtered zinc oxide nanoporous transducer
    Mozaffari, Sayed Ahmad
    Rahmanian, Reza
    Abedi, Mohammad
    Amoli, Hossein Salar
    ELECTROCHIMICA ACTA, 2014, 146 : 538 - 547
  • [37] Design and Fabrication of Enzymatic Potentiometric Biosensor Based on Flexible Printed Circuit Board for Glucose Detection
    Kuo, Po-Yu
    Liao, Chi-Han
    Wang, Tai-Hui
    Hsu, Ming-Tai
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2024, 23 (02) : 283 - 290
  • [38] The Sensing Analysis of the Potentiometric Enzymatic RuO2 Biosensor Based on FPCB for Dopamine Detection
    Kuo, Po-Yu
    Hsu, Ming-Tai
    Wang, Tai-Hui
    Liao, Chi-Han
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2024, 71 (01) : 790 - 796
  • [39] Inhibitive determination of mercury and other metal ions by potentiometric urea biosensor
    Krawczyk, TKV
    Moszczynska, T
    Trojanowicz, M
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) : 681 - 691