Resolution of a racemic pharmaceutical intermediate - A comparison of preparative HPLC, steady state recycling, and simulated moving bed

被引:50
作者
Grill, CA [1 ]
Miller, L [1 ]
Yan, TQ [1 ]
机构
[1] Pharm, Skokie, IL 60077 USA
关键词
steady state recycling; simulated moving bed; preparative chromatography; enantiomer separation;
D O I
10.1016/j.chroma.2003.11.049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Preparative HPLC and simulated moving bed (SMB) chromatography were used to resolve significant quantities of a racemic pharmaceutical intermediate. In addition, smaller scale studies using closed-loop recycling and steady state recycling (SSR) were performed so that a meaningful comparison of all these techniques could be made using the same real world separation. A highly optimized, six-column SMB process was clearly the superior technique and was used for the process-scale (247 kg of racemate) resolution. At the more moderate lab-scale (33 kg of racemate and 19 kg of racemate), a frequently used but less optimized eight-column SMB process was used. It was found that SSR was comparable to the lab-scale SMB process in productivity and solvent consumption. Thus, it appears that SSR can be a useful choice at such moderate scales. Finally, at moderate scales when neither SSR nor SMB is available, it was found that acceptable results were obtained with both closed-loop recycling and with a two-step preparative process. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 32 条
[1]  
ADAM P, 2000, Patent No. 56136198
[2]  
Bléhaut J, 2001, CHIM OGGI, V19, P24
[3]   Laboratory-developed simulated moving bed for chiral drug separations - Design of the system and separation of tramadol enantiomers [J].
Cavoy, E ;
Deltent, MF ;
Lehoucq, S ;
Miggiano, D .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (01) :49-57
[4]   PREPARATIVE CHROMATOGRAPHIC RESOLUTION OF RACEMATES ON CHIRAL STATIONARY PHASES ON LABORATORY AND PRODUCTION SCALES BY CLOSED-LOOP RECYCLING CHROMATOGRAPHY [J].
DINGENEN, J ;
KINKEL, JN .
JOURNAL OF CHROMATOGRAPHY A, 1994, 666 (1-2) :627-650
[5]   Simulated moving bed chromatographic resolution of a chiral antitussive [J].
Francotte, E ;
Richert, P ;
Mazzotti, M ;
Morbidelli, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 796 (02) :239-248
[6]   Preparative resolution of the enantiomers of tert-leucine derivatives by simulated moving bed chromatography [J].
Francotte, E ;
Leutert, T ;
La Vecchia, L ;
Ossola, F ;
Richert, P ;
Schmidt, A .
CHIRALITY, 2002, 14 (04) :313-317
[7]   Applications of simulated moving-bed chromatography to the separation of the enantiomers of chiral drugs [J].
Francotte, ER ;
Richert, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (01) :101-107
[8]  
Francotte ER, 1997, CHIMIA, V51, P717
[9]  
Franseen EK, 1997, SOC SEDIMENT GEOL SP, P271
[10]   Separation of a racemic pharmaceutical intermediate using closed-loop steady state recycling [J].
Grill, CM ;
Miller, L .
JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (02) :359-371