A comparison of lesion detection accuracy using digital mammography and flat-panel CT breast imaging

被引:5
作者
Gong, X [1 ]
Vedula, AA [1 ]
Thacker, S [1 ]
Glick, SJ [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
来源
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2005年 / 5745卷
关键词
mammography; breast imaging; cone-beam CT; flat-panel imager; ROC observer study;
D O I
10.1117/12.594955
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a 3D object onto a 2D plane. As an alternative, cone-beam CT breast imaging with a CsI based flat-panel imager (CTBI) has been proposed with the ability to provide 3D visualization of breast tissue. To investigate possible improvements in lesion detection accuracy using CTBI over digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through the flat-panel imager. Polyenergetic x-ray spectra of W/A1 50 kVp for CTBI and Mo/Mo 28 kVp for DM were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total mean glandular dose (MGD) of 4 mGy, which is approximately equivalent to that given in a conventional two-view screening mammography study. Since only one DM view was investigated here, the intensity of the DM x-ray spectra was defined to give 2 mGy MGD. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simulated by generating an ensemble of backgrounds with a power law spectrum. To evaluate lesion detection accuracy, a receiver operating characteristic (ROC) study was performed with 4 observers reading an ensemble of images for each case. The average area under the ROC curves (A(z)) was 0.94 for CTBI, and 0.81 for DM. Results indicate that a 5 mm lesion embedded in a structured breast phantom can be detected by CT breast imaging with statistically significant higher confidence than with digital mammography.
引用
收藏
页码:860 / 869
页数:10
相关论文
共 31 条
[21]  
Kopans D., 1998, BREAST IMAGING
[22]  
LIU B, 2005, P SPIE, V5474
[23]  
METZ CE, 1986, INVEST RADIOL, V21, P720, DOI 10.1097/00004424-198609000-00009
[24]   Estimating the accuracy of screening mammography: A meta-analysis [J].
Mushlin, AI ;
Kouides, RM ;
Shapiro, DE .
AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 1998, 14 (02) :143-153
[25]   Preliminary system characterization of flat panel detector-based cone beam CT for breast imaging [J].
Ning, RL ;
Yu, Y ;
Conover, D ;
Lu, XH ;
He, HG ;
Chen, ZK ;
Schiffhauer, L ;
Cullinan, J .
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 :292-303
[26]   EFFECT OF RANDOM BACKGROUND INHOMOGENEITY ON OBSERVER DETECTION PERFORMANCE [J].
ROLLAND, JP ;
BARRETT, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1992, 9 (05) :649-658
[27]   Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology [J].
Siewerdsen, JH ;
Antonuk, LE ;
ElMohri, Y ;
Yorkston, J ;
Huang, W ;
Boudry, JM ;
Cunningham, IA .
MEDICAL PHYSICS, 1997, 24 (01) :71-89
[28]   MEASUREMENT OF FORCE APPLIED DURING MAMMOGRAPHY [J].
SULLIVAN, DC ;
BEAM, CA ;
GOODMAN, SM ;
WATT, DL .
RADIOLOGY, 1991, 181 (02) :355-357
[29]   Normalized glandular dose (DgN) coefficients for flat-panel CT breast imaging [J].
Thacker, SC ;
Glick, SJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (24) :5433-5444
[30]  
*U CHIC K ROSSM LA, ROC SOFTW