A comparison of lesion detection accuracy using digital mammography and flat-panel CT breast imaging

被引:5
作者
Gong, X [1 ]
Vedula, AA [1 ]
Thacker, S [1 ]
Glick, SJ [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
来源
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2005年 / 5745卷
关键词
mammography; breast imaging; cone-beam CT; flat-panel imager; ROC observer study;
D O I
10.1117/12.594955
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a 3D object onto a 2D plane. As an alternative, cone-beam CT breast imaging with a CsI based flat-panel imager (CTBI) has been proposed with the ability to provide 3D visualization of breast tissue. To investigate possible improvements in lesion detection accuracy using CTBI over digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through the flat-panel imager. Polyenergetic x-ray spectra of W/A1 50 kVp for CTBI and Mo/Mo 28 kVp for DM were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total mean glandular dose (MGD) of 4 mGy, which is approximately equivalent to that given in a conventional two-view screening mammography study. Since only one DM view was investigated here, the intensity of the DM x-ray spectra was defined to give 2 mGy MGD. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simulated by generating an ensemble of backgrounds with a power law spectrum. To evaluate lesion detection accuracy, a receiver operating characteristic (ROC) study was performed with 4 observers reading an ensemble of images for each case. The average area under the ROC curves (A(z)) was 0.94 for CTBI, and 0.81 for DM. Results indicate that a 5 mm lesion embedded in a structured breast phantom can be detected by CT breast imaging with statistically significant higher confidence than with digital mammography.
引用
收藏
页码:860 / 869
页数:10
相关论文
共 31 条
[1]  
[Anonymous], 2003, BREAST IM REP DAT SY
[2]   Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications [J].
Antonuk, LE ;
Jee, KW ;
El-Mohri, Y ;
Maolinbay, M ;
Nassif, S ;
Rong, X ;
Zhao, Q ;
Siewerdsen, JH ;
Street, RA ;
Shah, KS .
MEDICAL PHYSICS, 2000, 27 (02) :289-306
[3]   Mammogram synthesis using a 3D simulation. 1. Breast tissue model and image acquisition simulation [J].
Bakic, PR ;
Albert, M ;
Brzakovic, D ;
Maidment, ADA .
MEDICAL PHYSICS, 2002, 29 (09) :2131-2139
[4]   Megalopinakophobia: Its symptoms and cures [J].
Barrett, HH ;
Myers, KJ ;
Gallas, B ;
Clarkson, E ;
Zhang, HB .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :299-307
[5]   Statistical texture synthesis of mammographic images with clustered lumpy backgrounds [J].
Bochud, FO ;
Abbey, CK ;
Eckstein, MP .
OPTICS EXPRESS, 1999, 4 (01) :33-43
[6]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[7]   Dedicated breast CT: Radiation dose and image quality evaluation [J].
Boone, JM ;
Nelson, TR ;
Lindfors, KK ;
Seibert, JA .
RADIOLOGY, 2001, 221 (03) :657-667
[8]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[9]  
BOONE JM, 2004, RSNA CATEGORICAL COU, P165
[10]   Human observer detection experiments with mammograms and power-law noise [J].
Burgess, AE ;
Jacobson, FL ;
Judy, PF .
MEDICAL PHYSICS, 2001, 28 (04) :419-437