The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique

被引:75
作者
Kwon, Heejin [1 ]
Cho, Jinhan [1 ]
Oh, Jongyeong [1 ]
Kim, Dongwon [1 ]
Cho, Junghyun [1 ]
Kim, Sanghyun [1 ]
Lee, Sangyun [1 ]
Lee, Jihyun [1 ]
机构
[1] Dong A Univ Hosp, Dept Radiol, Busan, South Korea
关键词
FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; IMAGE-QUALITY; CHEST CT; EXPOSURE;
D O I
10.1259/bjr.20150463
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. Methods: 27 consecutive patients (mean body mass index: 23.55 kg m(-2) underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. Results: At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19-49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. Conclusion: Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. Advances in knowledge: This study represents the first clinical research experiment to use ASIR-V, the newest version of iterative reconstruction. Use of the ASIR-V algorithm decreased image noise and increased image quality when compared with the ASIR and FBP methods. These results suggest that high-quality low-dose CT may represent a new clinical option.
引用
收藏
页数:8
相关论文
共 20 条
  • [1] Current concepts - Computed tomography - An increasing source of radiation exposure
    Brenner, David J.
    Hall, Eric J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) : 2277 - 2284
  • [2] Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on Radiation Dose and Image Quality in Aortic Dissection Studies: A Qualitative and Quantitative Analysis
    Cornfeld, Daniel
    Israel, Gary
    Detroy, Ezra
    Bokhari, Jamal
    Mojibian, Hamid
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) : W336 - W340
  • [3] Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study
    Deak, Zsuzsanna
    Grimm, Jochen M.
    Treitl, Marcus
    Geyer, Lucas L.
    Linsenmaier, Ulrich
    Koerner, Markus
    Reiser, Maximilian F.
    Wirth, Stefan
    [J]. RADIOLOGY, 2013, 266 (01) : 197 - 206
  • [4] Computed tomography-old ideas and new technology
    Fleischmann, Dominik
    Boas, F. Edward
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (03) : 510 - 517
  • [5] Reducing the Radiation Dose for CT Colonography Using Adaptive Statistical Iterative Reconstruction: A Pilot Study
    Flicek, Kristina T.
    Hara, Amy K.
    Silva, Alvin C.
    Wu, Qing
    Peter, Mary B.
    Johnson, C. Daniel
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) : 126 - 131
  • [6] Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space
    Hu, X. H.
    Ding, X. F.
    Wu, R. Z.
    Zhang, M. M.
    [J]. CLINICAL RADIOLOGY, 2011, 66 (11) : 1023 - 1029
  • [7] Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction
    Koc, Gonca
    Courtier, Jesse L.
    Phelps, Andrew
    Marcovici, Peter A.
    MacKenzie, John D.
    [J]. PEDIATRIC RADIOLOGY, 2014, 44 (07) : 787 - 794
  • [8] A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
    Leipsic, Jonathon
    Nguyen, Giang
    Brown, Jaqueline
    Sin, Don
    Mayo, John R.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1095 - 1099
  • [9] Lim K, 2015, J COMPUT ASSIST TOMO, V39, P443, DOI 10.1097/RCT.0000000000000216
  • [10] Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography
    May, Matthias S.
    Wuest, Wolfgang
    Brand, Michael
    Stahl, Christian
    Allmendinger, Thomas
    Schmidt, Bernhard
    Uder, Michael
    Lell, Michael M.