This paper presents results of an experimental study on the behavior of square and rectangular concrete-filled fiber reinforced polymer (FRP) tubes (CFFTs) under concentric compression. FRP tubes were designed as column confinement reinforcement and were manufactured using unidirectional carbon fiber sheets with fibers oriented in the hoop direction. The effects of the thickness and corner radius of the tube, sectional aspect ratio, and concrete strength on the axial behavior of CFFTs were investigated experimentally. Test results indicate that FRP confinement leads to substantial improvement in the ductility of both square and rectangular columns. Confinement provided by the FRP tube may also improve the axial load-carrying capacity of the square and rectangular columns if the confinement effectiveness of the FRP tube is sufficiently high. The results also indicate that the confinement effectiveness of FRP tubes is higher in square columns than in rectangular columns, and in both sections the effectiveness of confinement increases with the corner radius. Furthermore, for a given confinement level, improvement observed on the axial behavior of concrete due to confinement decreases with increasing concrete strength.
引用
收藏
页码:469 / 477
页数:9
相关论文
共 32 条
[1]  
AHMAD SH, 1982, J STRUCT DIV-ASCE, V108, P728
[2]  
*ASTM, 2001, D3039 ASTM, P105
[3]   Comparative study of models on confinement of concrete cylinders with fiber-reinforced polymer composites [J].
De Lorenzis, L ;
Tepfers, R .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2003, 7 (03) :219-237
[4]   Rectangular filament-wound glass fiber reinforced polymer tubes filled with concrete under flexural and axial loading: Experimental investigation [J].
Fam, A ;
Schnerch, D ;
Rizkalla, S .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2005, 9 (01) :25-33
[5]   Flexural Behavior of concrete-filled fiber-reinforced polymer circular tubes [J].
Fam, AZ ;
Rizkalla, SH .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2002, 6 (02) :123-132
[6]  
Fam AZ, 2001, ACI STRUCT J, V98, P280
[7]   Behavior of concrete columns confined by carbon composite tubes [J].
Hong, WK ;
Kim, HC .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 2004, 31 (02) :178-188
[8]   Design-oriented stress-strain model for FRP-confined concrete in rectangular columns [J].
Lam, L ;
Teng, JG .
JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2003, 22 (13) :1149-1186
[9]   Strength models for fiber-reinforced plastic-confined concrete [J].
Lam, L ;
Teng, JG .
JOURNAL OF STRUCTURAL ENGINEERING, 2002, 128 (05) :612-623
[10]   Design-oriented stress-strain model for FRP-confined concrete [J].
Lam, L ;
Teng, JG .
CONSTRUCTION AND BUILDING MATERIALS, 2003, 17 (6-7) :471-489