Direct Analysis of Doping Agents in Raw Urine Using Hydrophobic Paper Spray Mass Spectrometry

被引:36
作者
Rossini, Eduardo Luiz [1 ,2 ]
Kulyk, Dmytro S. [1 ]
Ansu-Gyeabourh, Emelia [1 ]
Sahraeian, Taghi [1 ]
Pezza, Helena Redigolo [2 ]
Badu-Tawiah, Abraham K. [1 ]
机构
[1] Ohio State Univ, Dept Chem & Biochem, Columbus, OH 43210 USA
[2] Sao Paulo State Univ UNESP, Inst Chem, Dept Analyt Chem, BR-14800900 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
analytical methods; paper spray ionization; paper modification; doping; anabolic agent; diuretic; ELECTROSPRAY-IONIZATION; QUANTITATIVE-ANALYSIS; SAMPLES; HYDROCHLOROTHIAZIDE; DECOMPOSITIONS; SENSITIVITY; PERFORMANCE; SUBSTRATE; DROPLETS; STEROIDS;
D O I
10.1021/jasms.0c00063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, the direct analysis of doping agents in urine samples with no sample preparation by a modified paper spray mass spectrometry (PS-MS) methodology has been demonstrated for the first time. We have described a paper surface treatment with trichloromethylsilane using a gas-phase reaction to increase the ionization of target compounds. This approach was applied for the analysis of two classes of banned substances in urine samples: anabolic agents (trenbolone and clenbuterol) and diuretics (furosemide and hydrochlorothiazide). Under optimized conditions, the developed methods presented satisfactory repeatability, and an analysis of variance showed linearity without lack-of-fit. Highly sensitive detections as low as sub-nanogram per milliliter levels, which is below the minimum required performance levels proposed by the World Anti-Doping Agency, have been reached using the hydrophobic PS-MS analysis without any preconcentration and cleanup step.
引用
收藏
页码:1212 / 1222
页数:11
相关论文
共 74 条
  • [41] Ultrasensitive Detection of Human Chorionic Gonadotropin Using Frequency Locked Microtoroid Optical Resonators
    Ozgur, Erol
    Roberts, Kara Ellen
    Ozgur, Ekin Ozge
    Gin, Adley Nathanael
    Bankhead, Jaden Robert
    Wang, Zhikun
    Su, Judith
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (18) : 11872 - 11878
  • [42] A Case of Increased C5-OH Acylcarnitine
    Peake, Roy W. A.
    [J]. CLINICAL CHEMISTRY, 2016, 62 (09) : 1278 - 1279
  • [43] Perspectives and strategies for anti-doping analysis
    Protti, Michele
    Mandrioli, Roberto
    Mercolini, Laura
    [J]. BIOANALYSIS, 2019, 11 (03) : 149 - 152
  • [44] Novel Fragmentation Pathways of Anionic Adducts of Steroids Formed by Electrospray Anion Attachment Involving Regioselective Attachment, Regiospecific Decompositions, Charge-Induced Pathways, and Ion-Dipole Complex Intermediates
    Rannulu, Nalaka S.
    Cole, Richard B.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (09) : 1558 - 1568
  • [45] Riboni N., 2019, Scientific reports, V9, P1
  • [46] Comprehensive analysis by liquid chromatography Q-Orbitrap mass spectrometry: Fast screening of peptides and organic molecules
    Sardela, V. F.
    Martucci, M. E. P.
    de Araujo, A. L. D.
    Leal, E. C.
    Oliveira, D. S.
    Carneiro, G. R. A.
    Deventer, K.
    Van Eenoo, P.
    Pereira, H. M. G.
    Aquino Neto, F. R.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2018, 53 (06): : 476 - 503
  • [47] Sport B, DOPING MORE 30 ATHLE
  • [48] Applications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time
    Swiner, Devin J.
    Jackson, Sierra
    Burris, Benjamin J.
    Badu-Tawiah, Abraham K.
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (01) : 183 - 202
  • [49] Microsampling with cotton thread: Storage and ultra-sensitive analysis by thread spray mass Spectrometry
    Swiner, Devin J.
    Jackson, Sierra
    Durisek, George R., III
    Walsh, Bridget K.
    Kouatli, Yaman
    Badu-Tawiah, Abraham K.
    [J]. ANALYTICA CHIMICA ACTA, 2019, 1082 : 98 - 105
  • [50] Mass spectrometry sampling under ambient conditions with desorption electrospray ionization
    Takáts, Z
    Wiseman, JM
    Gologan, B
    Cooks, RG
    [J]. SCIENCE, 2004, 306 (5695) : 471 - 473