Efficacy and Safety of Ologen Implant Versus Mitomycin C in Primary Trabeculectomy: A Meta-analysis of Randomized Clinical Trials

被引:24
作者
Ji, Qingshan [1 ]
Qi, Bing [2 ]
Liu, Lian [2 ]
Guo, Xiaoling [3 ]
Zhong, Jingxiang [2 ]
机构
[1] Anhui Med Univ, Affiliated Anhui Prov Hosp, Dept Ophthalmol, Hefei, Peoples R China
[2] Jinan Univ, Affiliated Hosp 1, Dept Ophthalmol, Guangzhou 510632, Guangdong, Peoples R China
[3] Jinan Univ, Inst Cell Biol, Dept Cell Biol, Guangzhou 510632, Guangdong, Peoples R China
关键词
trabeculectomy; Ologen; mitomycin C; glaucoma; meta-analysis; COLLAGEN MATRIX IMPLANT; INTRAOPERATIVE; 5-FLUOROURACIL; INTRAOCULAR-PRESSURE; GLAUCOMA; SURGERY; HYPOTONY;
D O I
10.1097/IJG.0000000000000147
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To assess the efficacy and safety of trabeculectomy with Ologen implant versus trabeculectomy with mitomycin C (MMC) for treatment of glaucoma.Patients and Methods:Medline, EMBASE, Web of Science, Cochrane Central Register of Controlled Trials, and Google Scholar were searched for relevant randomized controlled trials. The outcome measures of efficacy were intraocular pressure and glaucoma medications reductions, and success rate. Safety estimates were measured by relative ratio for complications.Results:A total of 6 studies including 224 participants were included in this meta-analysis. Ologen implant was associated with a numerically lower but nonsignificant percentage reduction in IOP compared with MMC. The pooled absolute IOP decreases from baseline (95% confidence interval) were: 13.28 mm Hg (11.33-15.23 mm Hg) versus 15.8 mm Hg (13.21-18.38 mm Hg) at 1 month; 12.95 mm Hg (11.45-14.44 mm Hg) versus 13.87 mm Hg (11.77-15.97 mm Hg) at 3 months; 11.44 mm Hg (8.77-14.11 mm Hg) versus 13.34 mm Hg (11.48-15.20 mm Hg) at 6 months; 10.05 mm Hg (7.14-12.96 mm Hg) versus 11.59 mm Hg (10.27-12.91 mm Hg) at 12 months; and 12.17 mm Hg (8.88-15.47 mm Hg) versus 10.64 mm Hg (8.15-13.12 mm Hg) at 24 months for Ologen implant versus MMC, respectively. There was no significant difference in the reduction in glaucoma medications, success rate, and incidence of complications.Conclusions:Trabeculectomy with an Ologen implant is comparable to the use of MMC with a similar long-term success rate. However, it does not seem to offer significant advantages of avoiding the potential complications related to MMC.
引用
收藏
页码:e88 / e94
页数:7
相关论文
共 28 条
[1]   Deep sclerectomy augmented with mitomycin C [J].
Anand, N ;
Atherley, C .
EYE, 2005, 19 (04) :442-450
[2]   Modification of trabeculectomy with single-dose intraoperative 5-Fluorouracil application [J].
Anand, N ;
Sahni, K ;
Menage, MJ .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (01) :83-89
[3]  
[Anonymous], J GLAUCOMA
[4]   Five-year results of trabeculectomy with mitomycin C [J].
Beckers, HJM ;
Kinders, KC ;
Webers, CAB .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2003, 241 (02) :106-110
[5]   Control of filtering bleb structure through tissue bioengineering: An animal model [J].
Chen, Henry Shen-Lih ;
Ritch, Robert ;
Krupin, Theodore ;
Hsu, Wei-Cherng .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (12) :5310-5314
[6]   Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: a 24-month, randomized clinical trial [J].
Cillino, S. ;
Di Pace, F. ;
Cillino, G. ;
Casuccio, A. .
EYE, 2011, 25 (12) :1598-1606
[7]   Meta-analysis of beta radiation augmentation for trabeculectomy - Results in distinct ethnic groups [J].
de Fendi, Ligia Issa ;
Arruda, Gustavo Viani ;
Costa, Vital Paulino ;
Paula, Jayter Silva .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2011, 74 (04) :300-305
[8]   The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions [J].
Downs, SH ;
Black, N .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1998, 52 (06) :377-384
[9]   Reduction of intraocular pressure and glaucoma progression - Results from the early manifest glaucoma trial [J].
Heijl, A ;
Leske, MC ;
Bengtsson, B ;
Hyman, L ;
Bengtsson, B ;
Hussein, M .
ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (10) :1268-1279
[10]  
Hsu WC, 2000, INVEST OPHTH VIS SCI, V41, P2404