Impingement in total hip arthroplasty: A geometric model

被引:13
作者
Pryce, Gregory M. [1 ]
Sabu, Bismaya [1 ]
Al-Hajjar, Mazen [1 ,2 ]
Wilcox, Ruth K. [1 ]
Thompson, Jonathan [1 ,2 ]
Isaac, Graham H. [1 ]
Board, Tim [3 ]
Williams, Sophie [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Leeds, W Yorkshire, England
[2] DePuy Synthes Joint Reconstruct, Leeds, W Yorkshire, England
[3] Wrightington Wigan & Leigh NHS Trust, Wigan, England
基金
英国工程与自然科学研究理事会;
关键词
Total hip arthroplasty; impingement; geometric model; surgical orientation; polyethylene; FEMORAL-HEAD SIZE; METAL-ON-METAL; BONY IMPINGEMENT; COMPUTER-MODEL; RISK-FACTORS; SAFE ZONE; DISLOCATION; ANGLE; RANGE; WEAR;
D O I
10.1177/09544119211069472
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total Hip Arthroplasty (THA) is one of the most common and successful surgical interventions. The survivorship at 10 years for the most commonly used systems is over 95%. However, the incidence of revision is usually much higher in the 0-1 year time period following the intervention. The most common reason for revision in this early time period is dislocation and subluxation, which may be defined as complete or permanent, and partial or temporary loss of contact between the bearing surfaces respectively. This study comprises the development of a geometric model of bone and an in situ total hip replacement, to predict the occurrence and location of bone and component impingement for a wide range of acetabular cup positions and for a series of frequently practiced activities of daily living. The model developed predicts that anterior-superior component impingement is associated with activities that result in posterior dislocation. The incidence may be reduced by increased cup anteversion and inclination. Posterior-inferior component impingement is associated with anterior dislocation activities. Its incidence may be reduced by decreased cup anteversion and inclination. A component impingement-free range was identified, running from when the cup was positioned with 45 degrees inclination and 25 degrees anteversion to 70 degrees inclination and 15 degrees-20 degrees anteversion.
引用
收藏
页码:504 / 514
页数:11
相关论文
共 59 条
[1]   Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement [J].
Al-Hajjar, Mazen ;
Leslie, Ian J. ;
Tipper, Joanne ;
Williams, Sophie ;
Fisher, John ;
Jennings, Louise M. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 95B (02) :263-268
[2]   Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[3]  
[Anonymous], 2010, 56 ANN M ORTH RES SO
[4]  
[Anonymous], 2020, NLG SOLIDARITY MINNE, P1, DOI DOI 10.1037/E620122011-001
[5]   Impingement and rim wear associated with early osteolysis after a total hip replacement - A case report [J].
Barrack, RL ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (07) :1218-1220
[6]   Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty [J].
Barrack, RL ;
Lavernia, C ;
Ries, M ;
Thornberry, R ;
Tozakoglou, E .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2001, 32 (04) :569-+
[7]  
Barrack Robert L, 2003, J Am Acad Orthop Surg, V11, P89
[8]   A computer model of the position of the combined component in the prevention of impingement in total hip replacement [J].
Barsoum, W. K. ;
Patterson, R. W. ;
Higuera, C. ;
Klika, A. K. ;
Krebs, V. E. ;
Molloy, R. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (06) :839-845
[9]  
Brown Thomas D, 2014, Iowa Orthop J, V34, P1
[10]   Impingement in total hip replacement: mechanisms and consequences [J].
Brown, Thomas D. ;
Callaghan, John J. .
CURRENT ORTHOPAEDICS, 2008, 22 (06) :376-391