Multi-lead model-based ECG signal denoising by guided filter

被引:26
作者
Hao, Huaqing [1 ]
Liu, Ming [1 ]
Xiong, Peng [1 ]
Du, Haiman [1 ]
Zhang, Hong [2 ]
Lin, Feng [3 ]
Hou, Zengguang [4 ]
Liu, Xiuling [1 ]
机构
[1] Hebei Univ, Key Lab Digital Med Engn Hebei Prov, Coll Elect & Informat Engn, Baoding, Peoples R China
[2] Hebei Univ, Affiliated Hosp, Baoding, Peoples R China
[3] Nanyang Technol Univ, Sch Comp Sci & Engn, Singapore, Singapore
[4] Chinese Acad Sci, Inst Automat, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrocardiograph (ECG) denoising; Multi-lead model-based ECG signal; Guided filter; Sparse autoencoder; CARDIOVASCULAR-DISEASE; DECOMPOSITION; ALGORITHM; FACE;
D O I
10.1016/j.engappai.2018.12.004
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The electrocardiogram (ECG) denoising is of paramount importance for accurate disease diagnosis, but individual differences bring great difficulties for ECG denoising, especially for Dynamic Electrocardiography (DCG). In this paper, a multi-lead model-based ECG signal denoising method is proposed, in which a guided filter is inherently adapted to denoise ECG signal. For each person, a patient-specific statistical model will be constructed by sparse autoencoder (SAE) which can effectively preserve the detailed signal features. Thus, the guided signal producing by the statistical model can perform well in the guided filter. Especially, even the sudden morphological changes, the denoised ECG signals can still be conserved. The results on the 12-lead Arrhythmia Database and the MIT-BIH Arrhythmia Database demonstrate that the signal-to-noise ratio (SNR) improvement of the proposed method can reach as high as 21.54 dB, and the mean squared error (MSE) is less than 0.0401. Besides achievement of minimum signal distortion in comparisons with the major of the current denoising algorithms for complex noise environment, the proposed method demonstrate robustness in the complex interferences, especially in tracing the sudden morphological changes of ECG signals. Due to the remarkable superiority in preserving diagnostic and detail features of ECG signals, the proposed method can handle ECG signals with abnormal heart beats, and then can improve the accuracy detection of the disease.
引用
收藏
页码:34 / 44
页数:11
相关论文
共 36 条
[1]   Hybridizing β-hill climbing with wavelet transform for denoising ECG signals [J].
Alyasseri, Zaid Abdi Alkareem ;
Khader, Ahamad Tajudin ;
Al-Betar, Mohammed Azmi ;
Awadallah, Mohammed A. .
INFORMATION SCIENCES, 2018, 429 :229-246
[2]   Non-invasive Fetal ECG Signal Quality Assessment for Multichannel Heart Rate Estimation [J].
Andreotti, Fernando ;
Graesser, Felix ;
Malberg, Hagen ;
Zaunseder, Sebastian .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (12) :2793-2802
[3]  
[Anonymous], 2017, IEEE T POWER SYST
[4]   The Burden of Cardiovascular Disease in Low- and Middle-Income Countries: Epidemiology and Management [J].
Bowry, Ashna D. K. ;
Lewey, Jennifer ;
Dugani, Sagar B. ;
Choudhry, Niteesh K. .
CANADIAN JOURNAL OF CARDIOLOGY, 2015, 31 (09) :1151-1159
[5]   Arrhythmia ECG Noise Reduction by Ensemble Empirical Mode Decomposition [J].
Chang, Kang-Ming .
SENSORS, 2010, 10 (06) :6063-6080
[6]   Transduction on Directed Graphs via Absorbing Random Walks [J].
De, Jaydeep ;
Zhang, Xiaowei ;
Lin, Feng ;
Cheng, Li .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2018, 40 (07) :1770-1784
[7]   Variational Mode Decomposition [J].
Dragomiretskiy, Konstantin ;
Zosso, Dominique .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2014, 62 (03) :531-544
[8]   Single Sample Face Recognition via Learning Deep Supervised Autoencoders [J].
Gao, Shenghua ;
Zhang, Yuting ;
Jia, Kui ;
Lu, Jiwen ;
Zhang, Yingying .
IEEE TRANSACTIONS ON INFORMATION FORENSICS AND SECURITY, 2015, 10 (10) :2108-2118
[9]   ON THE THEORY OF THE ELECTROCARDIOGRAM [J].
GESELOWITZ, DB .
PROCEEDINGS OF THE IEEE, 1989, 77 (06) :857-876
[10]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220