Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study

被引:15
作者
Fang, Xiao Kun [1 ]
Ni, Qian Qian [1 ]
Schoepf, U. Joseph [1 ,2 ]
Zhou, Chang Sheng [1 ]
Chen, Guo Zhong [1 ]
Luo, Song [1 ]
Fuller, Stephen R. [2 ]
De Cecco, Carlo N. [2 ]
Zhang, Long Jiang [1 ]
Lu, Guang Ming [1 ]
机构
[1] Nanjing Univ, Sch Med, Jinling Hosp, Dept Med Imaging, Nanjing 210002, Jiangsu, Peoples R China
[2] Med Univ South Carolina, Div Cardiovasc Imaging, Ashley River Tower,MSC 226,25 Courtenay Dr, Charleston, SC 29425 USA
关键词
CT perfusion; Stroke; Radiation dose; Low tube voltage; CT angiography; COMPUTED-TOMOGRAPHY-ANGIOGRAPHY; ACUTE ISCHEMIC-STROKE; INITIAL-EXPERIENCE; CEREBRAL PERFUSION; EXPOSURE; PROTOCOL;
D O I
10.1007/s00330-016-4225-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate image quality and diagnostic accuracy for acute infarct detection and radiation dose of 70 kVp whole brain CT perfusion (CTP) and CT angiography (CTA) reconstructed from CTP source data. Patients were divided into three groups (n = 50 each): group A, 80 kVp, 21 scanning time points; groups B, 70 kVp, 21 scanning time points; group C, 70 kVp, 17 scanning time points. Objective and subjective image quality of CTP and CTA were compared. Diagnostic accuracy for detecting acute infarct and cerebral artery stenosis aeyenaEuroe50 % was calculated for CTP and CTA with diffusion weighted imaging and digital subtraction angiography as reference standards. Effective radiation dose was compared. There were no differences in any perfusion parameter value between three groups (P > 0.05). No difference was found in subjective image quality between three groups (P > 0.05). Diagnostic accuracy for detecting acute infarct and vascular stenosis showed no difference between three groups (P > 0.05). Compared with group A, radiation doses of groups B and C were decreased by 28 % and 37 % (both P < 0.001), respectively. Compared with 80 kVp protocol, 70 kVp brain CTP allows comparable vascular and perfusion assessment and lower radiation dose while maintaining high diagnostic accuracy in detecting acute infarct. aEuro cent 70 kVp whole brain CTP can provide diagnostic image quality. aEuro cent 70 kVp CTP diagnostic accuracy was maintained vs. 80 kVp protocol. aEuro cent 70 kVp CTP radiation doses were lower than 80 kVp protocol.
引用
收藏
页码:4184 / 4193
页数:10
相关论文
共 27 条
[1]   CT Perfusion in Acute Ischemic Stroke: A Comparison of 2-Second and 1-Second Temporal Resolution [J].
Abels, B. ;
Klotz, E. ;
Tomandl, B. F. ;
Villablanca, J. P. ;
Kloska, S. P. ;
Lell, M. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1632-1639
[2]   Perfusion CT in Acute lschemic Stroke: A Qualitative and Quantitative Comparison of Deconvolution and Maximum Slope Approach [J].
Abels, B. ;
Klotz, E. ;
Tomandl, B. F. ;
Kloska, S. P. ;
Lell, M. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (09) :1690-1698
[3]   Hemorrhagic Transformation of Ischemic Stroke: Prediction with CT Perfusion [J].
Aviv, Richard I. ;
d'Esterre, Christopher D. ;
Murphy, Blake D. ;
Hopyan, Julia J. ;
Buck, Brian ;
Mallia, Gabriella ;
Li, Vivian ;
Zhang, Liying ;
Symons, Sean P. ;
Lee, Ting-Yim .
RADIOLOGY, 2009, 250 (03) :867-877
[4]  
Bogartz G., 2004, EUROPEAN GUIDELINES
[5]   Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography [J].
Chen, Guo Zhong ;
Zhang, Long Jiang ;
Schoepf, U. Joseph ;
Wichmann, Julian L. ;
Milliken, Cole M. ;
Zhou, Chang Sheng ;
Qi, Li ;
Luo, Song ;
Lu, Guang Ming .
EUROPEAN RADIOLOGY, 2015, 25 (05) :1453-1463
[6]   Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose [J].
Cho, Eun-Suk ;
Chung, Tae-Sub ;
Ahn, Sung Jun ;
Chong, KyoungHoon ;
Baek, Jang Hun ;
Suh, Sang Hyun .
EUROPEAN RADIOLOGY, 2015, 25 (05) :1421-1430
[7]   Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography [J].
Cho, Eun-Suk ;
Chung, Tae-Sub ;
Oh, Dae Kun ;
Choi, Hyun Seok ;
Suh, Sang Hyun ;
Lee, Hyeon-Kyeong ;
Lee, Kyung Hee .
INVESTIGATIVE RADIOLOGY, 2012, 47 (02) :142-147
[8]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[9]   Whole-Brain Adaptive 70-kVp Perfusion Imaging with Variable and Extended Sampling Improves Quality and Consistency While Reducing Dose [J].
Corcuera-Solano, I. ;
McLellan, A. M. ;
Doshi, A. H. ;
Pawha, P. S. ;
Tanenbaum, L. N. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) :2045-2051
[10]   Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT [J].
Durand, Sebastien ;
Paul, Jean-Francois .
EUROPEAN RADIOLOGY, 2014, 24 (12) :3003-3009