Ventriculoatrial conduction metrics for classification of ventricular tachycardia with 1:1 retrograde conduction in dual-chamber sensing implantable cardioverter defibrillators

被引:0
|
作者
Thompson, JA [1 ]
Jenkins, JM [1 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Med Comp Lab, Ann Arbor, MI 48109 USA
关键词
ventricular tachycardia; retrograde; implantable defibrillators;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The introduction of dual-chamber sensing in implantable cardioverter defibrillators (ICDs) has greatly reduced the incidence of false detection due to supraventricular tachycardias. The remaining arrhythmias which serve to confound classification are supraventricular tachycardias (SVTs) with 1:1 anterograde conduction and ventricular tachycardias (VT) with 1:1 retrograde conduction. An algorithm has been designed and tested (28 patients) which employs ventriculoatrial (VA) conduction measurements to separate 1:1 VTs from 1:1 SVTs. A study was conducted to assess realistic VA interval boundaries for classification of arrhythmias with 1:1 retrograde atrial conduction. Intracardiac atrial and ventricular recordings of 7 passages of VT with retrograde conduction 12 passages of atrioventricular nodal reentrant tachycardia (AVNRT), 3 passages of atrial tachycardia (AT), 8 passages of sinus tachycardia (ST), and 2 passages of orthodromic reentrant tachycardia (ORT) were analyzed. Automated real-time atrial and ventricular waveform recognition was performed on each passage and VA intervals were measured. Separation of VT with retrograde conduction from other 1:1 supraventricular tachycardias was effected by imposing discrete VA interval boundaries. VA boundaries of 80 ms to 234 ms classified 1:1 VT with 100% sensitivity (SENS) and 80% specificity (SPEC). Ln addition, the lower boundary completely classified AVNRT with 100% SENS and 100% SPEC, and all passages of ST were contained above the upper boundary. These findings could be of importance in algorithms for next-generation implantable cardioverter defibrillators which include two-chamber (atrial and ventricular) sensing and two-chamber inter val measurements.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 10 条
  • [1] DIFFERENTIATION OF SINUS TACHYCARDIA FROM VENTRICULAR-TACHYCARDIA WITH 1/1-VENTRICULOATRIAL CONDUCTION IN DUAL-CHAMBER IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS - FEASIBILITY OF A CRITERION BASED ON THE ATRIOVENTRICULAR INTERVAL
    LECARPENTIER, GL
    BAGA, JJ
    YANG, H
    STEINMAN, RT
    MEISSNER, MD
    LEHMANN, MH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1818 - 1831
  • [2] Ventriculoatrial conduction capability and prevalence of 1:1 retrograde conduction during inducible sustained monomorphic ventricular tachycardia in 305 implantable cardioverter defibrillator recipients
    Militianu, A
    Salacata, A
    Meissner, MD
    Grill, C
    Mahmud, R
    Palti, AJ
    David, JB
    Mosteller, R
    Lessmeier, TJ
    Baga, JJ
    Pires, LA
    Schuger, CD
    Steinman, RT
    Lehmann, MH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (10): : 2378 - 2384
  • [3] Initiation of Ventricular Tachycardia by Interruption of Pacemaker-Mediated Tachycardia in a Patient with a Dual-Chamber Implantable Cardioverter Defibrillator
    Van Gelder, Berry M.
    Meijer, Albert
    Dekker, Lukas R.
    Bracke, Frank A.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (09): : 1227 - 1230
  • [4] Discrimination between ventricular and supraventricular tachycardia by dual chamber cardioverter defibrillators:: Importance of the atrial sensing function
    Israel, CW
    Grönefeld, G
    Iscolo, N
    Stöppler, C
    Hohnloser, SH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (02): : 183 - 190
  • [5] A case of supraventricular tachycardia misdiagnosis after dual-chamber implantable cardioverter defibrillator implantation with His bundle pacing
    Sun, Xianchao
    Huang, Yue
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2023, 28 (03)
  • [6] Study of precursors of ventricular tachycardia from data stored in the memory of a dual chamber implantable cardioverter defibrillator
    Leenhardt, A
    Sadoul, N
    Mabo, P
    Kacet, S
    Lavergne, T
    Saoudi, N
    Iscolo, N
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (07): : 1454 - 1460
  • [7] Safety and efficacy of a dual chamber implantable cardioverter defibrillator capable of slow ventricular tachycardia discrimination:: A randomized study
    Mletzko, R
    Aliot, E
    Seidl, K
    Lavergne, T
    Mabo, P
    Hohnloser, S
    Böcker, D
    Schoels, W
    Sadoul, N
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (12): : 2275 - 2282
  • [8] Inappropriate shock delivery by implantable defibrillators with dual chamber pacing during nonsustained ventricular tachycardia in patients with heart block
    Sra, J
    Akhtar, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (06): : 1054 - 1056
  • [9] Delayed detection of ventricular tachycardia in a dual chamber rate adaptive pacing implantable cardioverter defibrillator: A case of intradevice interaction
    Shalaby, AA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (08): : 1164 - 1166
  • [10] A novel pacing maneuver to verify the postpacing interval minus the tachycardia cycle length while adjusting for decremental conduction: Using "dual-chamber entrainment" for improved supraventricular tachycardia discrimination
    Kaiser, Daniel W.
    Nasir, Javed M.
    Liem, L. Bing
    Brodt, Chad
    Motonaga, Kara S.
    Ceresnak, Scott R.
    Turakhia, Mintu P.
    Dubin, Anne M.
    HEART RHYTHM, 2019, 16 (05) : 717 - 723