Quantitative chemical exchange saturation transfer imaging of nuclear overhauser effects in acute ischemic stroke

被引:3
作者
Msayib, Yunus [1 ]
Harston, George W. J. [2 ]
Ray, Kevin J. [3 ]
Larkin, James R. [4 ,5 ]
Sutherland, Brad A. [2 ,6 ]
Sheerin, Fintan [2 ]
Blockley, Nicholas P. [3 ]
Okell, Thomas W. [3 ]
Jezzard, Peter [3 ]
Baldwin, Andrew [7 ]
Sibson, Nicola R. [4 ,5 ]
Kennedy, James [2 ]
Chappell, Michael A. [3 ,8 ,9 ]
机构
[1] Univ Oxford, Inst Biomed Engn, Dept Engn Sci, Oxford, England
[2] Univ Oxford, Acute Vasc Imaging Ctr, Radcliffe Dept Med, Oxford, England
[3] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, Oxford, England
[4] Univ Oxford, Dept Oncol, CRUK, Oxford, England
[5] Univ Oxford, MRC, Oxford Inst Radiat Oncol, Oxford, England
[6] Univ Tasmania, Sch Med, Hobart, Tas, Australia
[7] Univ Oxford, Dept Chem, Oxford, England
[8] Univ Nottingham, Sir Peter Mansfield Imaging Ctr, Sch Med, Nottingham, England
[9] Univ Nottingham, Sch Med, Mental Hlth & Clin Neurosci, Nottingham, England
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
acute ischemic stroke; chemical exchange saturation transfer; nuclear Overhauser effect; AMIDE PROTON-TRANSFER; MAGNETIZATION-TRANSFER; HUMAN BRAIN; TRANSFER CEST; TRANSFER APT; IN-VIVO; MRI; STATE; PH; RELAXATION;
D O I
10.1002/mrm.29187
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose In chemical exchange saturation transfer imaging, saturation effects between -2 to -5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4-pool Bloch-McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3-pool model. Methods MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch-McConnell models (4 pools, and a 3-pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naive mouse brain. Results The 4-pool measure of NOEs exhibited a different association with tissue outcome compared to 3-pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4-pool measure was elevated in patient white matter (1.20 +/- 0.20) and in animals (1.27 +/- 0.20). In the naive brain pH phantoms, significant positive correlation between the NOE and pH was observed. Conclusion Associations of NOEs with tissue pathology were found using the 4-pool metric that were not observed using the 3-pool approximation. The 4-pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.
引用
收藏
页码:341 / 356
页数:16
相关论文
共 50 条
  • [31] Nuclear Overhauser Enhancement-Mediated Magnetization Transfer Imaging in Glioma with Different Progression at 7 T
    Tang, Xiangyong
    Dai, Zhuozhi
    Xiao, Gang
    Yan, Gen
    Shen, Zhiwei
    Zhang, Tao
    Zhang, Guishan
    Zhuang, Zerui
    Shen, Yuanyu
    Zhang, Zhiyan
    Hu, Wei
    Wu, Renhua
    [J]. ACS CHEMICAL NEUROSCIENCE, 2017, 8 (01): : 60 - 66
  • [32] Variable Delay Multi-Pulse Train for Fast Chemical Exchange Saturation Transfer and Relayed-Nuclear Overhauser Enhancement MRI
    Xu, Jiadi
    Yadav, Nirbhay N.
    Bar-Shir, Amnon
    Jones, Craig K.
    Chan, Kannie W. Y.
    Zhang, Jiangyang
    Walczak, P.
    McMahon, Michael T.
    van Zijl, Peter C. M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1798 - 1812
  • [33] A rapid method for phosphocreatine-weighted imaging in muscle using double saturation power-chemical exchange saturation transfer
    Viswanathan, Malvika
    Kurmi, Yashwant
    Zu, Zhongliang
    [J]. NMR IN BIOMEDICINE, 2024, 37 (04)
  • [34] Adaptive denoising for chemical exchange saturation transfer MR imaging
    Breitling, Johannes
    Deshmane, Anagha
    Goerke, Steffen
    Korzowski, Andreas
    Herz, Kai
    Ladd, Mark E.
    Scheffler, Klaus
    Bachert, Peter
    Zaiss, Moritz
    [J]. NMR IN BIOMEDICINE, 2019, 32 (11)
  • [35] Investigating Hydroxyl Chemical Exchange Using a Variable Saturation Power Chemical Exchange Saturation Transfer (vCEST) Method at 3 T
    Clark, Daniel James
    Smith, Alex K.
    Dortch, Richard D.
    Knopp, Michael V.
    Smith, Seth A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 826 - 837
  • [36] B1 Power Optimization for Chemical Exchange Saturation Transfer Imaging: A Phantom Study Using Egg White for Amide Proton Transfer Imaging Applications in the Human Brain
    Kanazawa, Yuki
    Fushimi, Yasutaka
    Sakashita, Naotaka
    Okada, Tomohisa
    Arakawa, Yoshiki
    Miyazaki, Mitsue
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (01) : 86 - 94
  • [37] A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging
    Kim, Jinsuh
    Wu, Yin
    Guo, Yingkun
    Zheng, Hairong
    Sun, Phillip Zhe
    [J]. CONTRAST MEDIA & MOLECULAR IMAGING, 2015, 10 (03) : 163 - 178
  • [38] A fully convolutional network (FCN) based automated ischemic stroke segment method using chemical exchange saturation transfer imaging
    Zhao, Yingcheng
    Chen, Yibing
    Chen, Yanrong
    Zhang, Lihong
    Wang, Xiaoli
    He, Xiaowei
    [J]. MEDICAL PHYSICS, 2022, 49 (03) : 1635 - 1647
  • [39] High-resolution imaging of magnetisation transfer and nuclear Overhauser effect in the human visual cortex at 7 T
    Mougin, Olivier
    Clemence, Matthew
    Peters, Andrew
    Pitiot, Alain
    Gowland, Penny
    [J]. NMR IN BIOMEDICINE, 2013, 26 (11) : 1508 - 1517
  • [40] Exchange rates of creatine kinase metabolites: feasibility of imaging creatine by chemical exchange saturation transfer MRI
    Haris, Mohammad
    Nanga, Ravi Prakash Reddy
    Singh, Anup
    Cai, Kejia
    Kogan, Feliks
    Hariharan, Hari
    Reddy, Ravinder
    [J]. NMR IN BIOMEDICINE, 2012, 25 (11) : 1305 - 1309