HYDRAULIC PERFORMANCE OF AN ANNULAR PULSED DISC-AND-DOUGHNUT COLUMN

被引:28
作者
Liu, Jian-Quan [1 ]
Li, Shao-Wei [1 ]
Jing, Shan [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Annular Pulsed Disc-and-Doughnut Column (APDDC); hydraulic performance; air purge method; holdup; Sauter drop diameter; flooding; operating regimes; internal wettability; LIQUID-EXTRACTION COLUMNS; DISPERSED-PHASE HOLDUP; DROP SIZE; PREDICTION; CAPROLACTAM; TOLUENE;
D O I
10.1080/07366299.2015.1010891
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The annular pulsed disc-and-doughnut column (APDDC) is an important type of solvent-extraction equipment used in the PUREX process. Though it has been used in several commercial reprocessing plants in the world, there are few research results reported in the literature. In the present work, experiments were carried out in a stainless steel annular pulsed disc-and-doughnut column with aqueous phase and organic phase as the continuous fluid separately. The air-purge method was used to measure parameters including the two-phase densities, column weight, and two-phase interface location, which were fed back to a computer for column control. The holdup and Sauter drop diameter, the latter of which was calculated based on the gravitational settling model, are correlated as functions of the operating conditions (such as pulsation intensity, total flux, and flow ratio). Flooding holdup and throughput were determined experimentally and found in good agreement with those predicted by the model of the Sauter drop diameter. Based on the experimental data, operating regimes are divided referring to existing models. In addition, the effects of internal wettability on the hydraulic characteristics are also discussed.
引用
收藏
页码:385 / 406
页数:22
相关论文
共 32 条
  • [1] SIMULATION OF THE FLOW PATTERNS IN A DISK AND DOUGHNUT COLUMN
    ANGELOV, G
    JOURNE, E
    LINE, A
    GOURDON, C
    [J]. CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1990, 45 (02): : 87 - 97
  • [2] Buchalter, 1997, APPL BATEMAN PULSE C
  • [3] Use of neural networks for liquid-liquid extraction column modelling: an experimental study
    Chouai, A
    Cabassud, M
    Le Lann, MV
    Gourdon, C
    Casamatta, G
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2000, 39 (02) : 171 - 180
  • [4] Iseki T., GLOB 2005 TSUK JAP
  • [5] Iseki T., GLOB 2007 BOIS ID
  • [6] Pulsed Disc-and-Doughnut Column Performance
    Jahya, A. B.
    Stevens, G. W.
    Pratt, H. R. C.
    [J]. SOLVENT EXTRACTION AND ION EXCHANGE, 2009, 27 (01) : 63 - 82
  • [7] Comparison of the performance of a pulsed disc and doughnut column with a pulsed sieve plate liquid extraction column
    Jahya, AB
    Pratt, HRC
    Stevens, GW
    [J]. SOLVENT EXTRACTION AND ION EXCHANGE, 2005, 23 (03) : 307 - 317
  • [8] [景山 JING Shan], 2008, [原子能科学技术, Atomic Energy Science and Technology], V42, P292
  • [9] [景山 JING Shan], 2008, [原子能科学技术, Atomic Energy Science and Technology], V42, P711
  • [10] [景山 JING Shan], 2007, [原子能科学技术, Atomic Energy Science and Technology], V41, P716