Correlating electrochemical active surface area with humidity and its application in proton exchange membrane fuel cell modeling

被引:17
|
作者
Wu, Kangcheng [1 ]
Wang, Zixuan [1 ]
Zhang, Guobin [1 ]
Fan, Linhao [1 ]
Zhu, Mengqian [1 ]
Xie, Xu [1 ]
Du, Qing [1 ]
Zu, Bingfeng [2 ]
Jiao, Kui [1 ]
机构
[1] Tianjin Univ, State Key Lab Engines, 135 Yaguan Rd, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Internal Combust Engine Res Inst, 92 Weijin Rd, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Proton exchange membrane fuel cell; Electrochemical active surface area; Semi-empirical equation; Numerical application; Activation loss; CATHODE CATALYST LAYER; RELATIVE-HUMIDITY; WATER SORPTION; COLD START; ELECTRODES; TEMPERATURE; DEPENDENCE; RATIO;
D O I
10.1016/j.enconman.2021.114982
中图分类号
O414.1 [热力学];
学科分类号
摘要
The electrochemical active surface area has a vital influence on the performance of proton exchange membrane fuel cells. In this study, a universal semi-empirical equation of the electrochemical active surface area in the catalyst layer of fuel cells is proposed based on self-designed experiments, aiming to improve the predictive accuracy of numerical models under low humidity conditions. The generalization of this equation is also verified with the other nine catalyst layers of different compositions. At very low water content corresponding to low inlet humidification operations, the electrochemical active surface area is generally low and increases sharply with the increment of water content. When the water content exceeds a certain threshold value, the electrochemical active surface area becomes independent of water content. In addition, the electrochemical active surface area significantly decreases as the operating temperature increases. Consequently, including this newly proposed electrochemical active surface area equation in conventional full-cell models is of significant importance to accurately predict the activation loss and performance of fuel cells under both cold-start and normal operation conditions, especially at low humidification, which is validated against experimental data. In contrast with the conventional constant electrochemical active surface area assumption, this equation improves the model accuracy from about 70% to be higher than 90% under low humidity conditions.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] High surface area graphite as alternative support for proton exchange membrane fuel cell catalysts
    Ferreira-Aparicio, P.
    Folgado, M. A.
    Daza, L.
    JOURNAL OF POWER SOURCES, 2009, 192 (01) : 57 - 62
  • [22] Proton exchange membrane development and processing for fuel cell application
    Bebin, Philippe
    Galiano, Herve
    THERMEC 2006, PTS 1-5, 2007, 539-543 : 1327 - +
  • [23] Application of graphene oxide in proton exchange membrane for fuel cell
    Fu, Fengyan
    Zhang, Jie
    Cheng, Jingquan
    Zhang, Sufang
    Zhang, Yan
    Fan, Jing
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2019, 38 (05): : 2233 - 2241
  • [24] Sensibility Study on Electrochemical Impedance of Proton Exchange Membrane Fuel Cell
    Zhang S.
    Dai H.
    Yuan H.
    Ming P.
    Wei X.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2021, 57 (14): : 40 - 51
  • [25] Fuel crossover and internal current in proton exchange membrane fuel cell modeling
    Chakraborty, Uttara
    APPLIED ENERGY, 2016, 163 : 60 - 62
  • [26] Analysis and modeling of a membrane electrode assembly in a proton exchange membrane fuel cell
    Orhan, Mehmet F.
    Saka, Kenan
    Kahraman, Huseyin
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2020, 12 (04)
  • [27] Modeling and Design of Gradient Membrane Electrode for Proton Exchange Membrane Fuel Cell
    Wang, Houpeng
    Cheng, Tao
    Peng, Qian
    Zhang, Jiakang
    Gu, Xianrui
    Gong, Xuehui
    Yang, Xue
    Lin, Wei
    Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section), 2024, 40 (02): : 493 - 500
  • [28] Measurement of humidity distribution in a proton exchange membrane fuel cell using channel embedded humidity sensors
    Dept. of Mechanical Engineering, Hannam Univ, Korea, Republic of
    Trans. Korean Soc. Mech. Eng., B, 5 (397-403): : 397 - 403
  • [29] MICRO HUMIDITY SENSOR FOR MONITORING WATER FLOODING IN A PROTON EXCHANGE MEMBRANE FUEL CELL
    Lee, Chi-Yuan
    Fan, Wei-Yuan
    Chang, Chih-Ping
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2012, 9 (05) : 389 - 397
  • [30] Proton exchange membrane fuel cell model for aging predictions: Simulated equivalent active surface area loss and comparisons with durability tests
    Robin, C.
    Gerard, M.
    Quinaud, M.
    d'Arbigny, J.
    Bultel, Y.
    JOURNAL OF POWER SOURCES, 2016, 326 : 417 - 427