Impact of Time-of-Flight PET on Whole-Body Oncologic Studies: A Human Observer Lesion Detection and Localization Study

被引:79
|
作者
Surti, Suleman [1 ]
Scheuermann, Joshua [1 ]
El Fakhri, Georges [2 ,3 ]
Daube-Witherspoon, Margaret E. [1 ]
Lim, Ruth [2 ,3 ]
Abi-Hatem, Nathalie [2 ,3 ]
Moussallem, Elie [2 ,3 ]
Benard, Francois [4 ]
Mankoff, David [5 ]
Karp, Joel S. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Div Nucl Med & Mol Imaging, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Boston, MA 02114 USA
[4] BC Canc Res Ctr, Dept Mol Oncol, Vancouver, BC, Canada
[5] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
基金
美国国家卫生研究院;
关键词
lesion detection; human observers; LROC; time-of-flight PET; PERFORMANCE; SCANNER; BENEFIT;
D O I
10.2967/jnumed.110.086678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Phantom studies have shown improved lesion detection performance with time-of-flight (TOF) PET. In this study, we evaluate the benefit of fully 3-dimensional, TOF PET in clinical whole-body oncology using human observers to localize and detect lesions in realistic patient anatomic backgrounds. Our hypothesis is that with TOF imaging we achieve improved lesion detection and localization for clinically challenging tasks, with a bigger impact in large patients. Methods: One hundred patient studies with normal (18)F-FDG uptake were chosen. Spheres (diameter, 10 mm) were imaged in air at variable locations in the scanner field of view corresponding to lung and liver locations within each patient. Sphere data were corrected for attenuation and merged with patient data to produce fused list-mode data files with lesions added to normal-uptake scans. All list files were reconstructed with full corrections and with or without the TOF kernel using a list-mode iterative algorithm. The images were presented to readers to localize and report the presence or absence of a lesion and their confidence level. The interpretation results were then analyzed to calculate the probability of correct localization and detection, and the area under the localized receiver operating characteristic (LROC) curve. The results were analyzed as a function of scan time per bed position, patient body mass index (BMI < 26 and BMI >= 26), and type of imaging (TOF and non-TOF). Results: Our results showed that longer scan times led to an improved area under the LROC curve for all patient sizes. With TOF imaging, there was a bigger increase in the area under the LROC curve for larger patients (BMI > 26). Finally, we saw smaller differences in the area under the LROC curve for large and small patients when longer scan times were combined with TOF imaging. Conclusion: A combination of longer scan time (3 min in this study) and TOF imaging provides the best performance for imaging large patients or a low-uptake lesion in small or large patients. This imaging protocol also provides similar performance for all patient sizes for lesions in the same organ type with similar relative uptake, indicating an ability to provide a uniform clinical diagnosis in most oncologic lesion detection tasks.
引用
收藏
页码:712 / 719
页数:8
相关论文
共 21 条
  • [1] Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET
    El Fakhri, Georges
    Surti, Suleman
    Trott, Cathryn M.
    Scheuermann, Joshua
    Karp, Joel S.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (03) : 347 - 353
  • [2] Effect of Scan Time on Oncologic Lesion Detection in Whole-Body PET
    Kadrmas, Dan J.
    Oktay, M. Bugrahan
    Casey, Michael E.
    Hamill, James J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1940 - 1947
  • [3] Impact of Time-of-Flight on PET Tumor Detection
    Kadrmas, Dan J.
    Casey, Michael E.
    Conti, Maurizio
    Jakoby, Bjoern W.
    Lois, Cristina
    Townsend, David W.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (08) : 1315 - 1323
  • [4] Waveform-Sampling Electronics for a Whole-Body Time-of-Flight PET Scanner
    Ashmanskas, W. J.
    LeGeyt, B. C.
    Newcomer, F. M.
    Panetta, J. V.
    Ryan, W. A.
    Van Berg, R.
    Wiener, R. I.
    Karp, J. S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1174 - 1181
  • [5] Clinical evaluation of whole-body oncologic PET with time-of-flight and point-spread function for the hybrid PET/MR system
    Shang, Kun
    Cui, Bixiao
    Ma, Jie
    Shuai, Dongmei
    Liang, Zhigang
    Jansen, Floris
    Zhou, Yun
    Lu, Jie
    Zhao, Guoguang
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 70 - 75
  • [6] Determination of Accuracy and Precision of Lesion Uptake Measurements in Human Subjects with Time-of-Flight PET
    Daube-Witherspoon, Margaret E.
    Surti, Suleman
    Perkins, Amy E.
    Karp, Joel S.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (04) : 602 - 607
  • [7] Lesion detection and quantification performance of the Tachyon-I time-of-flight PET scanner: phantom and human studies
    Zhang, Xuezhu
    Peng, Qiyu
    Zhou, Jian
    Huber, Jennifer S.
    Moses, William W.
    Qi, Jinyi
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (06):
  • [8] Clinical impact of time-of-flight and point response modeling in PET reconstructions: a lesion detection study
    Schaefferkoetter, Joshua
    Casey, Michael
    Townsend, David
    El Fakhri, Georges
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (05): : 1465 - 1478
  • [9] Experimental evaluation of a simple lesion detection task with time-of-flight PET
    Surti, S.
    Karp, J. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (02): : 373 - 384
  • [10] Whole-Body Single-Bed Time-of-Flight RPC-PET: Simulation of Axial and Planar Sensitivities With NEMA and Anthropomorphic Phantoms
    Crespo, Paulo
    Reis, Joao
    Couceiro, Miguel
    Blanco, Alberto
    Ferreira, Nuno C.
    Marques, Rui Ferreira
    Martins, Paulo
    Fonte, Paulo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (03) : 520 - 529