A Well-Dispersed Pt/Ni/TiO2 Nanotubes Modified Electrode as an Amperometric Non-Enzymatic Glucose Biosensor

被引:9
作者
Mahshid, Sahar Sadat [1 ,2 ]
Luo, Shenglian [1 ]
Yang, Lixia [2 ]
Mahshid, Sara [1 ,2 ]
Dolati, Abolghasem [2 ]
Ghorbani, Mohammad [2 ]
Cai, Qingyun [1 ]
机构
[1] Hunan Univ, Dept Chem, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
[2] Sharif Univ Technol, Mat Sci & Engn Dept, Tehran, Iran
基金
美国国家科学基金会;
关键词
Pt/Ni/TiO2 Nanotubes Electrode; Electrodeposition; Non-Enzyme; Glucose Biosensor; PHOTOCATALYTIC ACTIVITIES; TITANATE NANOTUBES; TIO2; NANOTUBES; SENSOR; NANOPARTICLES; OXIDATION; AG;
D O I
10.1166/sl.2011.1718
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study a novel Pt/Ni nanostructure consisting of nano-bushes and nanocubes was fabricated onto TiO2 nanotubes. The scanning electron microscopy images showed that a large amount of well-dispersed nano-architectures had uniformly covered all over the surface which made an electrode with high surface area. It was obviously seen that the nanocube structures mainly consists of Ni had been grown on top of each other while the Pt colonies represented bush-like structures. As a non-enzymatic glucose biosensor, the Pt/Ni TiO2 nanotubes modified electrode exhibited an excellent performance. The proposed biosensor had two linear ranges for detection of glucose from 0 to 0.12 mM (correlation coefficient of 0.999) and from 0.1 to 10 mM (correlation coefficient of 0.997) with the detection sensitivity of 1629 and 259 mu A mM(-1) cm(-2) respectively. Moreover, its experimental detection limit was 0.5 mu M (Signal/Noise = 3). The experiment results also revealed that the electrode exhibited good reproducibility and long-term stability, as well as high selectivity with no interference from other oxidable species. All these results suggest that the proposed Pt/Ni/TiO2 nanotubes modified electrode can provide a promising material for the non-enzymatic glucose biosensor designs.
引用
收藏
页码:1598 / 1605
页数:8
相关论文
共 26 条
[1]   Self-ordering electrochemistry: a review on growth and functionality of TiO2 nanotubes and other self-aligned MOx structures [J].
Ghicov, Andrei ;
Schmuki, Patrik .
CHEMICAL COMMUNICATIONS, 2009, (20) :2791-2808
[2]  
Grimes C. A., 2009, TIO2 ARRAYS SYNTHESI
[3]   Gold nanocatalysts supported on protonic titanate nanotubes and titania nanocrystals [J].
Jiang, Jinhua ;
Gao, Qiuming ;
Chen, Zhi .
JOURNAL OF MOLECULAR CATALYSIS A-CHEMICAL, 2008, 280 (1-2) :233-239
[4]   An electro-catalytic biosensor fabricated with Pt-Au nanoparticle-decorated titania nanotube array [J].
Kang, Qing ;
Yang, Lixia ;
Cai, Qingyun .
BIOELECTROCHEMISTRY, 2008, 74 (01) :62-65
[5]   Formation and mechanistic study of self-ordered TiO2 nanotubes on Ti substrate [J].
Kang, Soon Hyung ;
Kim, Jae-Yup ;
Kim, Hyun Sik ;
Sung, Yung-Eun .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2008, 14 (01) :52-59
[6]   A sensitive nonenzymatic glucose sensor in alkaline media with a copper nanocluster/multiwall carbon nano tube-modified glassy carbon electrode [J].
Kang, Xinhuang ;
Mai, Zhibin ;
Zou, Xiaoyong ;
Cai, Peixiang ;
Mo, Jinyuan .
ANALYTICAL BIOCHEMISTRY, 2007, 363 (01) :143-150
[7]   Mechanical behavior of nanocrystalline metals and alloys [J].
Kumar, KS ;
Van Swygenhoven, H ;
Suresh, S .
ACTA MATERIALIA, 2003, 51 (19) :5743-5774
[8]   Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode [J].
Liu, Yang ;
Teng, Hong ;
Hou, Haoqing ;
You, Tianyan .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (11) :3329-3334
[9]   A nano-Ni based ultrasensitive nonenzymatic electrochemical sensor for glucose: Enhancing sensitivity through a nanowire array strategy [J].
Lu, Li-Min ;
Zhang, Li ;
Qu, Feng-Li ;
Lu, Hai-Xia ;
Zhang, Xiao-Bing ;
Wu, Zai-Sheng ;
Huan, Shuang-Yan ;
Wang, Qiu-An ;
Shen, Guo-Li ;
Yu, Ru-Qin .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (01) :218-223
[10]   Filling of TiO2 nanotubes by self-doping and electrodeposition [J].
Macak, Jan M. ;
Gong, Bin G. ;
Hueppe, Michael ;
Schmuki, Patrik .
ADVANCED MATERIALS, 2007, 19 (19) :3027-+