Iterative image reconstruction in spectral-CT

被引:3
作者
Hernandez, Daniel [1 ]
Michel, Eric [1 ]
Kim, Hye S. [1 ]
Kim, Jae G. [1 ]
Han, Byung H. [1 ]
Cho, Min H. [1 ]
Lee, Soo Y. [1 ]
机构
[1] Kyung Hee Univ, Dept Biomed Engn, Seoul, South Korea
来源
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING | 2012年 / 8313卷
关键词
Spectral-CT; photo-counting detector; CdTe; total variation minimization; SIRT; filtered back-projection;
D O I
10.1117/12.911258
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Scan time of spectral-CTs is much longer than conventional CTs due to limited number of x-ray photons detectable by photon-counting detectors. However, the spectral pixel information in spectral-CT has much richer information on physiological and pathological status of the tissues than the CT-number in conventional CT, which makes the spectral-CT one of the promising future imaging modalities. One simple way to reduce the scan time in spectral-CT imaging is to reduce the number of views in the acquisition of projection data. But, this may result in poorer SNR and strong streak artifacts which can severely compromise the image quality. In this work, spectral-CT projection data were obtained from a lab-built spectral-CT consisting of a single CdTe photon counting detector, a micro-focus x-ray tube and scan mechanics. For the image reconstruction, we used two iterative image reconstruction methods, the simultaneous iterative reconstruction technique (SIRT) and the total variation minimization based on conjugate gradient method (CG-TV), along with the filtered back-projection (FBP) to compare the image quality. From the imaging of the iodine containing phantoms, we have observed that SIRT and CG-TV are superior to the FBP method in terms of SNR and streak artifacts.
引用
收藏
页数:8
相关论文
共 5 条
  • [1] Computational analysis and improvement of SIRT
    Gregor, Jens
    Benson, Thomas
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (07) : 918 - 924
  • [2] Sparse MRI: The application of compressed sensing for rapid MR imaging
    Lustig, Michael
    Donoho, David
    Pauly, John M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1182 - 1195
  • [3] Enhancement of the ultrasound images by modified anisotropic diffusion method
    Mittal, Deepti
    Kumar, Vinod
    Saxena, Suresh Chandra
    Khandelwal, Niranjan
    Kalra, Naveen
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (12) : 1281 - 1291
  • [4] NONLINEAR TOTAL VARIATION BASED NOISE REMOVAL ALGORITHMS
    RUDIN, LI
    OSHER, S
    FATEMI, E
    [J]. PHYSICA D, 1992, 60 (1-4): : 259 - 268
  • [5] Energy-discriminating X-ray computed tomography system utilizing a cadmium telluride detector
    Sato, Eiichi
    Abderyim, Purkhet
    Enomoto, Toshiyuki
    Watanabe, Manabu
    Hitomi, Keitaro
    Takahasi, Kiyomi
    Sato, Shigehiro
    Ogawae, Akira
    Onagawa, Jun
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3) : 262 - 265