Simple transfer calibration method for a Cimel Sun-Moon photometer: calculating lunar calibration coefficients from Sun calibration constants

被引:16
|
作者
Li, Zhengqiang [1 ]
Li, Kaitao [1 ]
Li, Donghui [1 ]
Yang, Jiuchun [2 ]
Xu, Hua [1 ]
Goloub, Philippe [3 ]
Victori, Stephane [4 ]
机构
[1] Chinese Acad Sci, Inst Remote Sensing & Digital Earth, State Environm Protect Key Lab Satellite Remote S, Beijing 100101, Peoples R China
[2] Hefei Univ Technol, Sch Instrument Sci & Optoelect Engn, Hefei 230009, Peoples R China
[3] Univ Lille 1, Lab Opt Atmospher, F-59655 Villeneuve Dascq, France
[4] Cimel Elect, F-75011 Paris, France
基金
中国国家自然科学基金;
关键词
PERFORMANCE; IRRADIANCE; EXTINCTION;
D O I
10.1364/AO.55.007624
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The Cimel new technologies allow both daytime and nighttime aerosol optical depth (AOD) measurements. Although the daytime AOD calibration protocols are well established, accurate and simple nighttime calibration is still a challenging task. Standard lunar-Langley and intercomparison calibration methods both require specific conditions in terms of atmospheric stability and site condition. Additionally, the lunar irradiance model also has some known limits on its uncertainty. This paper presents a simple calibration method that transfers the direct-Sun calibration constant, V-0,V-Sun, to the lunar irradiance calibration coefficient, C-Moon. Our approach is a pure calculation method, independent of site limits, e.g., Moon phase. The method is also not affected by the lunar irradiance model limitations, which is the largest error source of traditional calibration methods. Besides, this new transfer calibration approach is easy to use in the field since C-Moon can be obtained directly once V-0,V-Sun is known. Error analysis suggests that the average uncertainty of C-Moon over the 440-1640 nm bands obtained with the transfer method is 2.4%-2.8%, depending on the V-0,V-Sun approach (Langley or intercomparison), which is comparable with that of lunar-Langley approach, theoretically. In this paper, the Sun-Moon transfer and the Langley methods are compared based on site measurements in Beijing, and the day-night measurement continuity and performance are analyzed. (C) 2016 Optical Society of America
引用
收藏
页码:7624 / 7630
页数:7
相关论文
共 46 条
  • [41] Calibration Transfer from Pharmaceutical Powder Mixtures to Compacts Using the Prediction Augmented Classical Least Squares (PACLS) Method
    Shi, Zhenqi
    Igne, Benoit
    Bondi, Robert W., Jr.
    Drennen, James K., III
    Anderson, Carl A.
    APPLIED SPECTROSCOPY, 2012, 66 (09) : 1075 - 1081
  • [42] Calibration transfer of a Raman spectroscopic quantification method from at-line to in-line assessment of liquid detergent compositions
    Brouckaert, D.
    Uyttersprot, J. -S.
    Broeckx, W.
    De Beer, T.
    ANALYTICA CHIMICA ACTA, 2017, 971 : 14 - 25
  • [43] A method for predicting relative position errors in dual-robot systems via knowledge transfer from geometric and nongeometric calibration
    Cao, Siming
    Wang, Hongfeng
    Guo, Yingjie
    Zhu, Weidong
    Ke, Yinglin
    INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2024, 51 (02): : 314 - 325
  • [44] A simple and rapid external standard calibration HPLC method for determination of lumefantrine in dried blood spot samples from malaria patients in Botswana
    Brooks, Blondie O.
    Paganotti, Giacomo Maria
    Massele, Amos
    Sepako, Enoch
    Adiukwu, Paul
    Sichilongo, Kwenga Festus
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (01)
  • [45] Evaluation of equilibrium constants from potentiometric Z-pH normalized curves using the partial least squares (PLS) self-calibration method
    Perutka, J
    Havel, J
    Galindo, L
    Montelongo, FG
    Leon, JJA
    CHEMICAL PAPERS, 1996, 50 (04) : 162 - 166
  • [46] Calibration transfer of a Raman spectroscopic quantification method for the assessment of liquid detergent compositions from at-line laboratory to in-line industrial scale
    Brouckaert, D.
    Uyttersprot, J-S.
    Broeckx, W.
    De Beer, T.
    TALANTA, 2018, 179 : 386 - 392