Analysis of the performance of a flow reactor for use with microcolumn HPLC

被引:15
作者
Beisler, AT [1 ]
Sahlin, E [1 ]
Schaefer, KE [1 ]
Weber, SG [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Chevron Sci Ctr, Pittsburgh, PA 15260 USA
关键词
D O I
10.1021/ac034785d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Postcolumn derivatization reactions can be used to improve detector sensitivity or selectivity. The advantages of capillary chromatography for trace analysis could be augmented if there were postcolumn reactors suitable for microchromatographic systems. However, postcolumn derivatization is a challenge because of the small peak volumes associated with capillary columns. We have developed a postcolumn flow reactor from microchannels formed in fluorinated ethylene propylene and 50-mum fused-silica tubing for use with capillary HPLC analyses. Theoretical and experimental evidence show that the reactor, which operates in the Taylor dispersion regime, enables contact of analyte and derivatization streams purely by diffusion. Reactor lengths as short as 2 cm allow formation of copper(II)-peptide complexes that are detected electrochemically at a carbon fiber microelectrode. The reactor has been used with 100-mum-i.d. columns with insignificant effects (i.e., <3%) on peak band spreading. Theoretical calculations indicate that even smaller i.d. columns can be used with little effect on chromatographic resolution.
引用
收藏
页码:639 / 645
页数:7
相关论文
共 22 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   Simple method for the quantitative examination of extra column band broadening in microchromatographic systems [J].
Beisler, AT ;
Schaefer, KE ;
Weber, SG .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (02) :247-251
[3]   DETECTION OF BIOACTIVE OLIGOPEPTIDES AFTER MICROBORE HPLC WITH ELECTROCHEMICAL DETECTION OF THEIR CU(II) COMPLEXES - EFFECT OF OPERATING PARAMETERS ON SENSITIVITY AND SELECTIVITY [J].
CHEN, JG ;
WEBER, SG .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3596-3604
[4]  
Chiem NH, 1998, CLIN CHEM, V44, P591
[5]   EVALUATION AND COMPARISON OF REACTION DETECTORS [J].
DEELDER, RS ;
KUIJPERS, ATJM ;
VANDENBERG, JHM .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :545-561
[6]  
GIDDINGS JC, 1991, UNIFIED SEPARATION S, P77
[7]   Microchip device for performing enzyme assays [J].
Hadd, AG ;
Raymond, DE ;
Halliwell, JW ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3407-3412
[8]   A picoliter-volume mixer for microfluidic analytical systems [J].
He, B ;
Burke, BJ ;
Zhang, X ;
Zhang, R ;
Regnier, FE .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :1942-1947
[9]   OPTIMAL-DESIGN OF TUBULAR AND PACKED-BED HOMOGENEOUS FLOW CHEMICAL REACTORS FOR COLUMN LIQUID-CHROMATOGRAPHY [J].
HUBER, JFK ;
JONKER, KM ;
POPPE, H .
ANALYTICAL CHEMISTRY, 1980, 52 (01) :2-9
[10]   PREPARATION AND EVALUATION OF PACKED CAPILLARY LIQUID-CHROMATOGRAPHY COLUMNS WITH INNER DIAMETERS FROM 20-MU-M TO 50-MU-M [J].
KENNEDY, RT ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1128-1135