Development and evaluation of a new 3-D digitization and computer graphic system to study the anatomic tissue and restoration surfaces

被引:12
作者
Dastane, A [1 ]
Vaidyanathan, TK [1 ]
Vaidyanathan, J [1 ]
Mehra, R [1 ]
Hesby, R [1 ]
机构
[1] UNIV MED & DENT NEW JERSEY,NEW JERSEY DENT SCH,DEPT PROSTHODONT & BIOMAT,NEWARK,NJ 07103
关键词
D O I
10.1111/j.1365-2842.1996.tb00808.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
It is necessary to visualize and reconstruct tissue anatomic surfaces accurately for a variety of oral rehabilitation applications such as surface wear characterization and automated fabrication of dental restorations, accuracy of reproduction of impression and die materials, etc. In this investigation, a 3-D digitization and computer-graphic system was developed for surface characterization. The hardware consists of a profiler assembly for digitization in an MTS biomechanical test system with an artificial mouth, an IBM PS/2 computer model 70 for data processing and a Hewlett-Packard laser printer for hardcopy outputs. The software used includes a commercially available Surfer 3-D graphics package, a public domain data-fitting alignment software and an inhouse Pascal program for intercommunication plus some other limited tasks. Surfaces were digitized before and after rotation by angular displacement, the digital data were interpolated by Surfer to provide a data grid and the surfaces were computer graphically reconstructed: Misaligned surfaces were aligned by the data-fitting alignment software under different choices of parameters. The effect of different interpolation parameters (e.g. grid size, method of interpolation) and extent of rotation on the alignment accuracy was determined. The results indicate that improved alignment accuracy results from optimization of interpolation parameters and minimization of the initial misorientation between the digitized surfaces. The method provides important advantages for surface reconstruction and visualization, such as overlay of sequentially generated surfaces and accurate alignment of pairs of surfaces with small misalignment.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 15 条
[1]   DETERMINATION OF THE ACCURACY OF 3 DIE SYSTEMS [J].
BLOEM, TJ ;
CZERNIAWSKI, B ;
LUKE, J ;
LANG, BR .
JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (06) :758-762
[2]   MACHINE CONTOURING USING MINIMUM CURVATURE [J].
BRIGGS, IC .
GEOPHYSICS, 1974, 39 (01) :39-48
[3]  
CECECI S, 1984, BYTE, P340
[4]  
DASTANE A, 1991, J DENTAL RES, V60
[5]  
DAVIS JC, 1986, STATISTICS DATA ANAL
[6]  
DeLong R, 1985, Dent Mater, V1, P27, DOI 10.1016/S0109-5641(85)80061-0
[7]   DEVELOPMENT OF AN ARTIFICIAL ORAL ENVIRONMENT FOR THE TESTING OF DENTAL RESTORATIVES - BI-AXIAL FORCE AND MOVEMENT CONTROL [J].
DELONG, R ;
DOUGLAS, WH .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (01) :32-36
[8]  
DeLong R, 1985, Dent Mater, V1, P238, DOI 10.1016/S0109-5641(85)80050-6
[9]  
DELONG R, 1990, 12TH P ANN INT C IEE, V12, P2054
[10]  
DURET F, 1988, J AM DENT ASSOC, V17, P715