共 50 条
Prosthesis Survival Rates and Prosthetic Complications of Implant-Supported Fixed Dental Prostheses in Partially Edentulous Patients
被引:12
|作者:
Chochlidakis, Konstantinos
[1
]
Fraser, David
[2
]
Lampraki, Evangelia
Einarsdottir, Erna R.
[3
]
Barmak, Abdul Basir
[4
]
Papaspyridakos, Panos
[1
,5
]
Ercoli, Carlo
[1
]
Tsigarida, Alexandra
[2
]
机构:
[1] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, 625 Elmwood Ave, Rochester, NY 14620 USA
[2] Univ Rochester, Eastman Inst Oral Hlth, Dept Periodontol, Rochester, NY 14620 USA
[3] Univ Iceland, Dept Prosthodont, Reykjavik, Iceland
[4] Univ Rochester, Eastman Inst Oral Hlth, Rochester, NY 14620 USA
[5] Tufts Sch Dent Med, Dept Prosthodont, Boston, MA USA
来源:
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY
|
2020年
/
29卷
/
06期
关键词:
Dental prosthesis design;
dental prosthesis retention;
fixed dental prosthesis;
fixed partial denture;
implant-supported;
mechanical complications;
prosthesis survival;
technical complications;
QUALITY-OF-LIFE;
RECONSTRUCTIONS;
MANAGEMENT;
D O I:
10.1111/jopr.13185
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Purpose To determine the prevalence and distribution of prosthetic complications affecting implant-supported fixed dental prostheses (ISFDPs). Materials and Methods Subjects previously treated with one or more ISFDP(s) were identified from an electronic health record search and recalled for comprehensive clinical examination. Past prosthesis failures and complications were identified from the patient records while any existing complications, not previously recorded, were assessed during examination. ISFDP survival and failure rates were calculated with Kaplan-Meier curves and life table analysis, while regression Poisson analysis was used to identify associations between outcomes and possible patient- and prosthesis-based risk factors. Results Seventy-four subjects with 107 ISFDPs were enrolled in the study with a mean time between prosthesis delivery and exam of 3.14 years (range: 1.00-9.00 years). Four prostheses failed, resulting in a cumulative prosthesis survival rate of 96.26%. Prosthetic complications affected 48.59% of ISFDPs, the majority (94.87%) of them minor complications. Only the use of a nightguard was associated with a lower prevalence of prosthetic screw loosening (HR 0.11, 95% CI 0.02-0.59, p = 0.007) while no outcome differences were noted for other variables. Patient satisfaction was high regardless of presence or number of complications. Conclusions ISFDPs demonstrated a high survival rate and overall high, patient-reported satisfaction. Minor prosthetic complications were common but were only significantly associated with nightguard use.
引用
收藏
页码:479 / 488
页数:10
相关论文