Comparison of six phantoms for entrance skin dose evaluation in 11 standard X-ray examinations

被引:19
作者
Compagnone, Gaetano [1 ]
Pagan, Laura [1 ]
Bergamini, Carlo [1 ]
机构
[1] St Orsola Marcello Malpighi Hosp, Dept Phys Med, I-40138 Bologna, Italy
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2005年 / 6卷 / 01期
关键词
anthropomorphic phantom; diagnostic radiology; entrance dose measurements; entrance skin exposure; phantom study;
D O I
10.1120/jacmp.2023.25326
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Entrance skin dose (ESD) is an important parameter for assessing the dose received by a patient in a single radiographic exposure. The most useful way to evaluate ESD is either by direct measurement on phantoms using an ionization chamber or using calculations based on a mathematical model. We compared six phantoms ( three anthropomorphic, two physical, and one mathematical) in 11 standard clinical examinations (anterior-posterior (AP) abdomen, posterior-anterior (PA) chest, AP chest, lateral (LAT) chest, AP lumbar spine, LAT lumbar spine, LAT lumbo-sacral joint, AP pelvis, PA skull, LAT skull, and AP urinary tract) for two reasons: to determine the conversion factors to use for ESDs measured on different phantoms and to validate the mathematical model used. First, a comparison was done between the three anthropomorphic phantoms (Alderson Rando, chest RSD-77SPL, and 3M skull) and the two physical phantoms ( Uniform and AAPM 31); for each examination we obtained "relative entrance skin dose factors." Second, we compared these five phantoms with the mathematical phantom: the overall accuracy of the model was better than 14%. Total mathematical model and total ionization chamber uncertainties, calculated by quadratic propagation of errors of the single components, were estimated to be on the order of +/- 12% and +/- 3%, respectively. To reduce the most significant source of uncertainty, the overall accuracy of the model was recalculated using new backscatter factors. The overall accuracy of the model improved: better than 12%. For each examination an anthropomorphic phantom was considered as the gold standard relative to the physical phantoms. In this way, it was possible to analyze the variations in phantom design and characteristics. Finally, the mathematical model was validated by more than 400 measurements taken on different phantoms and using a variety of radiological equipment. We conclude that the mathematical model can be used satisfactorily in ESD evaluations because it optimizes available resources, it is based on direct measurements, and it is an easy dynamic tool.
引用
收藏
页码:101 / 113
页数:13
相关论文
共 25 条
[1]  
*AAPM, 1990, 31 AAPM
[2]  
[Anonymous], 1999, PHYS DIAGNOSTIC RADI
[3]   The impact of increased Al filtration on x-ray tube loading and image quality in diagnostic radiology [J].
Behrman, RH .
MEDICAL PHYSICS, 2003, 30 (01) :69-78
[4]   BEAM QUALITY INDEPENDENT ATTENUATION PHANTOM FOR ESTIMATING PATIENT EXPOSURE FROM X-RAY AUTOMATIC EXPOSURE CONTROLLED CHEST EXAMINATIONS [J].
CONWAY, BJ ;
BUTLER, PF ;
DUFF, JE ;
FEWELL, TR ;
GROSS, RE ;
JENNINGS, RJ ;
KOUSTENIS, GH ;
MCCROHAN, JL ;
RUETER, FG ;
SHOWALTER, CK .
MEDICAL PHYSICS, 1984, 11 (06) :827-832
[5]   A PATIENT-EQUIVALENT ATTENUATION PHANTOM FOR ESTIMATING PATIENT EXPOSURES FROM AUTOMATIC EXPOSURE CONTROLLED X-RAY EXAMINATIONS OF THE ABDOMEN AND LUMBOSACRAL SPINE [J].
CONWAY, BJ ;
DUFF, JE ;
FEWELL, TR ;
JENNINGS, RJ ;
ROTHENBERG, LN ;
FLEISCHMAN, RC .
MEDICAL PHYSICS, 1990, 17 (03) :448-453
[6]   PERFORMING JCAHO DOSE CALCULATIONS WITH THE AID OF A MICROCOMPUTER SPREADSHEET PROGRAM [J].
DAVID, G ;
PRICE, SC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (04) :863-866
[7]  
European Commission, 1996, EUROPEAN GUIDELINES
[8]   DEPENDENCE OF THE PHOTON BACKSCATTER FACTOR FOR WATER ON SOURCE-TO-PHANTOM DISTANCE AND IRRADIATION FIELD SIZE [J].
GROSSWENDT, B .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1233-1245
[9]   A mathematical spread sheet application for production of entrance skin exposure nomograms [J].
Harpen, MD .
MEDICAL PHYSICS, 1996, 23 (02) :241-242
[10]   BACKSCATTER FACTORS FOR DIAGNOSTIC-RADIOLOGY (1-4 MM AL HVL) [J].
HARRISON, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (12) :1465-1474