DETERMINATION OF ORGANIC AND INORGANIC MERCURY SPECIES AS EMETINE DITHIOCARBAMATE COMPLEXES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH ELECTROGENERATED TRIS(2,2′-BIPYRIDINE)RUTHENIUM(III) CHEMILUMINESCENCE DETECTION

被引:14
作者
Kodamatani, Hitoshi [1 ]
Kanzaki, Ryo [1 ]
Tomiyasu, Takashi [1 ]
Saito, Keiitsu [2 ]
Kono, Yuriko [3 ]
机构
[1] Kagoshima Univ, Grad Sch Sci & Engn, Div Earth & Environm Sci, Kagoshima 8900065, Japan
[2] Kobe Univ, Div Human Environm, Grad Sch Human Dev & Environm, Nada Ku, Kobe, Hyogo 657, Japan
[3] Kagoshima Univ, Environm & Safety Sect, Kagoshima 8900065, Japan
基金
日本学术振兴会;
关键词
Chemiluminescence; HPLC; Mercury; Methylmercury; Tris(2,2 '-bipyridine)ruthenium(III); ATOMIC FLUORESCENCE SPECTROMETRY; POINT EXTRACTION PRECONCENTRATION; DERIVATIZATION REAGENT; SPECIATION ANALYSIS; FISH SAMPLES; METHYLMERCURY; ELECTROCHEMILUMINESCENCE; SEPARATION; SEDIMENTS; AMINES;
D O I
10.1080/00032719.2011.565442
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive method for simultaneous determination of organic and inorganic mercury species has been developed and is presented in this study. The method is based on complex formation of mercury species with the emetine dithiocarbamate (emetine-CS(2)) ligand, HPLC separation, and tris(2,2'-bipyridine) ruthenium(III) chemiluminescence detection. The complexation reactions of the mercury species and emetine-CS(2) ligand occurred instantaneously upon the addition of emetine-CS(2) solution to the solution containing the mercury species. The complete separation of these complexes was achieved using an ODS column with 20mM NaH(2)PO(4)-acetonitrile (52:48, v/v) containing 30mM NaClO(4) as an ion-pair reagent. The calibration graphs of these complexes were linear in the range from 1-100 mu g/L. The detection limits were 0.27 mu g/L, 0.33 mu g/L, 0.39 mu g/L, and 0.17 mu g/L for methylmercury, ethylmercury, phenylmercury, and the mercury ion, respectively, at a signal-to-noise ratio of 3. The developed technique was validated by analyzing certified reference materials, CRM7402-a (cod fish, NMIJ) and CE464 (tuna fish, ERM), in combination with sonication-assisted acid leaching and liquid-liquid extraction. The emetine-CS2 ligand has been used for extraction, separation, and detection of mercury species. The results determined using the proposed method were in good agreement with the values of the certified reference materials. The MeHg(+) and EtHg(+) recoveries for the spiked samples were found to be almost 100%.
引用
收藏
页码:2769 / 2779
页数:11
相关论文
共 29 条
[1]  
Bard A.J., 2004, Electrogenerated Chemiluminescence
[2]   GC-ECD determination of methylmercury in sediment samples using a SPB-608 capillary column after alkaline digestion [J].
Caricchia, AM ;
Minervini, G ;
Soldati, P ;
Chiavarini, S ;
Ubaldi, C ;
Morabito, R .
MICROCHEMICAL JOURNAL, 1997, 55 (01) :44-55
[3]   Determination of ultra-trace amount methyl-, phenyl- and inorganic mercury in environmental and biological samples by liquid chromatography with inductively coupled plasma mass spectrometry after cloud point extraction preconcentration [J].
Chen, Jianguo ;
Chen, Hengwu ;
Jin, Xianzhong ;
Chen, Haiting .
TALANTA, 2009, 77 (04) :1381-1387
[4]   Determination of Hg and organomercury species following SPME: A review [J].
Diez, Sergi ;
Bayona, Josep M. .
TALANTA, 2008, 77 (01) :21-27
[5]   Recent applications of electrogenerated chemiluminescence in chemical analysis [J].
Fähnrich, KA ;
Pravda, M ;
Guilbault, GG .
TALANTA, 2001, 54 (04) :531-559
[6]   Determination of trace amounts of methylmercury in sediment and biological tissue by using water vapor distillation in combination with RP C18 preconcentration and HPLC-HPF/HHPN-ICP-MS [J].
Falter, R ;
Ilgen, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (03) :401-406
[7]   Analytical applications of tris(2,2′-bipyridyl)ruthenium(III) as a chemiluminescent reagent [J].
Gerardi, RD ;
Barnett, NW ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :1-41
[8]   Tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence [J].
Gorman, BA ;
Francis, PS ;
Barnett, NW .
ANALYST, 2006, 131 (05) :616-639
[9]  
Hamid H.-M., 2008, J AOAC INT, V91, P1453
[10]   Simple and sensitive method for determination of glycoalkaloids in potato tubers by high-performance liquid chromatography with chemiluminescence detection [J].
Kodamatani, H ;
Saito, K ;
Niina, N ;
Yamazaki, S ;
Tanaka, Y .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1100 (01) :26-31