Spinal cord blood flow measurement by arterial spin labeling

被引:30
作者
Duhamel, Guillaume [1 ]
Callot, Virginie [1 ]
Cozzone, Patrick J. [1 ]
Kober, Frank [1 ]
机构
[1] Univ Aix Marseille 2, Fac Med Marseille, CRMBM, UMR 6612,CNRS, F-13385 Marseille 5, France
关键词
spinal cord; perfusion; ASL; SCBF; mouse; high-field;
D O I
10.1002/mrm.21567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The assessment of spinal cord (SC) hemodynamics, and especially SC blood flow (SCBF), plays a key role in the pathophysiological description and understanding of many SC diseases such as ischemia, or spinal cord injury. SCBF has been previously measured in animals with invasive techniques such as autoradiography or labeled microspheres; no MR technique, however, has been proposed so far. The possibility of quantitatively measuring SCBF in mice using MRI was investigated using a presaturated FAIR (flow-sensitive alternating inversion recovery) arterial spin labeling (ASL) technique. SCBF measurements were performed at the cervical level of the mouse as well as on the brain so as to use cerebral blood flow (CBF) values as internal references. With a spatial resolution of 133 x 133 mu m(2) for the SCBF maps, absolute regional perfusion values could be measured within the different structures of the SC (gray matter, white matter, and cerebrospinal fluid area). Similar perfusion values were found in SC gray matter (330 +/- 90 mL/100g/min) and in brain (295 +/- 22 mL/100g/min for thalamus). This result, in agreement with SCBF/CBF measurements performed with non-MR techniques, opens new perspectives for noninvasive longitudinal and in vivo animal studies. Application to human experiments may also be possible.
引用
收藏
页码:846 / 854
页数:9
相关论文
共 44 条
[1]   High-resolution MR imaging of the rat spinal cord in vivo in a wide-bore magnet at 17.6 Tesla [J].
Behr, VC ;
Weber, T ;
Neuberger, T ;
Vroemen, M ;
Weidner, N ;
Bogdahn, U ;
Haase, A ;
Jakob, PM ;
Faber, C .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 17 (3-6) :353-358
[2]   TECHNIQUES FOR MEASURING SPINAL-CORD BLOOD-FLOW [J].
BIDABE, AM ;
GIN, AM ;
POINTILLART, V ;
DEBEAUFORT, DG ;
SESAY, M ;
CAILLE, JM .
ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1992, 11 (06) :644-651
[3]   Simple, low-cost multipurpose RF coil for MR microscopy at 9.4 T [J].
Bilgen, M .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :937-940
[4]   Magnetic resonance imaging of mouse spinal cord [J].
Bilgen, M ;
Al-Hafez, B ;
Berman, NEJ ;
Festoff, BW .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1226-1231
[5]   In vivo magnetic resonance microscopy of rat spinal cord at 7 T using implantable RF coils [J].
Bilgen, M ;
Elshafiey, I ;
Narayana, PA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1250-1253
[6]   Dynamic contrast-enhanced MRI of experimental spinal cord injury: In vivo serial studies [J].
Bilgen, M ;
Abbe, R ;
Narayana, PA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :614-622
[7]   Nuclear magnetic resonance microimaging of mouse spinal cord in vivo [J].
Bonny, JM ;
Gaviria, M ;
Donnat, JP ;
Jean, B ;
Privat, A ;
Renou, JP .
NEUROBIOLOGY OF DISEASE, 2004, 15 (03) :474-482
[8]  
Calamante F, 1996, NMR BIOMED, V9, P79, DOI 10.1002/(SICI)1099-1492(199604)9:2<79::AID-NBM399>3.0.CO
[9]  
2-4
[10]  
CALLOT V, 2007, P 15 ANN M ISMRM BER, P2429