Progress of Polyaniline Glucose Sensors for Diabetes Mellitus Management Utilizing Enzymatic and Non-Enzymatic Detection

被引:44
作者
Osuna, Velia [1 ]
Vega-Rios, Alejandro [2 ]
Zaragoza-Contreras, Erasto Armando [2 ]
Alziri Estrada-Moreno, Ivan [1 ]
Dominguez, Rocio B. [1 ]
机构
[1] CONACYT CIMAV, SC, Av Miguel Cervantes 120, Chihuahua 31136, Mexico
[2] Ctr Invest Mat Avanzados, SC, Av Miguel Cervantes 120, Chihuahua 31136, Mexico
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 03期
关键词
glucose monitoring; polyaniline; diabetes mellitus; enzymatic; non-enzymatic; DIRECT ELECTRON-TRANSFER; CARBON-PASTE ELECTRODE; ACID) COMPOSITE FILM; ELECTROCHEMICAL GLUCOSE; POTASSIUM FERRICYANIDE; CONDUCTING POLYANILINE; OXIDE HYBRID; BIOSENSOR; POLYMER; NANOFIBERS;
D O I
10.3390/bios12030137
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose measurement is a fundamental tool in the daily care of Diabetes Mellitus (DM) patients and healthcare professionals. While there is an established market for glucose sensors, the rising number of DM cases has promoted intensive research to provide accurate systems for glucose monitoring. Polyaniline (PAni) is a conductive polymer with a linear conjugated backbone with sequences of single C-C and double C=C bonds. This unique structure produces attractive features for the design of sensing systems such as conductivity, biocompatibility, environmental stability, tunable electrochemical properties, and antibacterial activity. PAni-based glucose sensors (PBGS) were actively developed in past years, using either enzymatic or non-enzymatic principles. In these devices, PAni played roles as a conductive material for electron transfer, biocompatible matrix for enzymatic immobilization, or sensitive layer for detection. In this review, we covered the development of PBGS from 2015 to the present, and it is not even exhaustive; it provides an overview of advances and achievements for enzymatic and non-enzymatic PBGB PBGS for self-monitoring and continuous blood glucose monitoring. Additionally, the limitations of PBGB PBGS to advance into robust and stable technology and the challenges associated with their implementation are presented and discussed.
引用
收藏
页数:25
相关论文
共 140 条
  • [1] ELECTROCHEMICAL OXIDATION OF GLUCOSE ON SINGLE-CRYSTAL GOLD SURFACES
    ADZIC, RR
    HSIAO, MW
    YEAGER, EB
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 260 (02): : 475 - 485
  • [2] Enzyme-free impedimetric glucose sensor based on gold nanoparticles/polyaniline composite film
    Ahammad, A. J. Saleh
    Al Mamun, Abdullah
    Akter, Tania
    Mamun, M. A.
    Faraezi, S.
    Monira, F. Z.
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2016, 20 (07) : 1933 - 1939
  • [3] Amperometric glucose biosensing performance of a novel graphene nanoplatelets-iron phthalocyanine incorporated conducting hydrogel
    Al-Sagur, H.
    Sundaram, Komathi Shanmuga
    Kaya, E. N.
    Durmus, M.
    Basova, T., V
    Hassan, A.
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 139
  • [4] A glucose biosensor based on novel Lutetium bis-phthalocyanine incorporated silica-polyaniline conducting nanobeads
    Al-Sagur, H.
    Komathi, S.
    Karakas, H.
    Atilla, D.
    Gurek, A. G.
    Basova, T.
    Farmilo, N.
    Hassan, A. K.
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 102 : 637 - 645
  • [5] A novel glucose sensor using lutetium phthalocyanine as redox mediator in reduced graphene oxide conducting polymer multifunctional hydrogel
    Al-Sagur, H.
    Komathi, S.
    Khan, M. A.
    Gurek, A. G.
    Hassan, A.
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 92 : 638 - 645
  • [6] Application of polymerized multiporous nanofiber of SnO2 for designing a bienzyme glucose biosensor based on HRP/GOx
    Alim, Samiul
    Kafi, A. K. M.
    Rajan, Jose
    Yusoff, Mashitah M.
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2019, 123 : 1028 - 1034
  • [7] Nanocages-augmented aligned polyaniline nanowires as unique platform for electrochemical non-enzymatic glucose biosensor
    Ameen, Sadia
    Akhtar, M. Shaheer
    Shin, Hyung Shik
    [J]. APPLIED CATALYSIS A-GENERAL, 2016, 517 : 21 - 29
  • [9] Sensitive and Enzyme-Free Glucose Sensor Based on Copper Nanowires/Polyaniline/Reduced Graphene Oxide Nanocomposite Ink
    Anand, Vijay Kumar
    Bhatt, Kapil
    Kumar, Sandeep
    Archana, B.
    Sharma, Sandeep
    Singh, Karamvir
    Gupta, Monish
    Goyal, Rakesh
    Virdi, G. S.
    [J]. INTERNATIONAL JOURNAL OF NANOSCIENCE, 2021, 20 (02)
  • [10] Highly sensitive and reusable Cu+2/polyaniline/reduced graphene oxide nanocomposite ink-based non-enzymatic glucose sensor
    Anand, Vijay Kumar
    Bukke, Archana
    Bhatt, Kapil
    Kumar, Sandeep
    Sharma, Sandeep
    Goyal, Rakesh
    Virdi, G. S.
    [J]. APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2020, 126 (07):