Morphological Features and Important Parameters of Large Optic Discs for Diagnosing Glaucoma

被引:16
作者
Okimoto, Satoshi [1 ]
Yamashita, Keiko [2 ]
Shibata, Tetsuo [2 ]
Kiuchi, Yoshiaki [1 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed Sci, Dept Ophthalmol & Visual Sci, Hiroshima, Japan
[2] Shibata Eye Clin, Amagasaki, Hyogo, Japan
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
HEIDELBERG RETINA TOMOGRAPH; NERVE-FIBER LAYER; PRIMARY OPEN-ANGLE; FIELD LOSS; STRUCTURAL DAMAGE; TENSION GLAUCOMA; SIZE; REPRODUCIBILITY; DEFINITION; PREVALENCE;
D O I
10.1371/journal.pone.0118920
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To compare the optic disc parameters of glaucomatous eyes to those of non-glaucomatous eyes with large discs. Methods We studied 225 consecutive eyes with large optic discs (>2.82 mm2): 91 eyes with glaucoma and 134 eyes without glaucoma. An eye was diagnosed with glaucoma when visual field defects were detected by the Humphrey Field Analyzer. All of the Heidelberg Retina Tomograph II (HRT II) parameters were compared between the non-glaucomatous and glaucomatous eyes. A logistic regression analysis of the HRT II parameters was used to establish a new formula for diagnosing glaucoma, and the sensitivity and specificity of the Moorfields Regression Analysis (MRA) was compared to the findings made by our analyses. Results The mean disc area was 3.44 +/- 0.50 mm2 in the non-glaucomatous group and 3.40 +/- 0.52 mm2 in the glaucoma group. The cup area, cup volume, cup-to-disc area ratio, linear cup/disc ratio, mean cup depth, and the maximum cup depth were significantly larger in glaucomatous eyes than in the non-glaucomatous eyes. The rim area, rim volume, cup shape measurement, mean retinal nerve fiber layer (RNFL) thickness, and RFNL cross-sectional area were significantly smaller in glaucomatous eyes than in non-glaucomatous eyes. The cup-to-disc area ratio, the height variation contour (HVC), and the RNFL cross-sectional area were important parameters for diagnosing the early stage glaucoma, and the cup-to-disc area ratio and cup volume were useful for diagnosing advanced stage glaucoma in eyes with a large optic disc. The new formula had higher sensitivity and specificity for diagnosing glaucoma than MRA. Conclusions The cup-to-disc area ratio, HVC, RNFL cross-sectional area, and cup volume were important parameters for diagnosing glaucoma in eyes with a large optic disc. The important disc parameters to diagnose glaucoma depend on the stage of glaucoma in patients with large discs.
引用
收藏
页数:13
相关论文
共 33 条
[1]   Laser Scanning Tomography of Optic Discs of the Normal Japanese Population in a Population-based Setting [J].
Abe, Haruki ;
Shirakashi, Motohiro ;
Tsutsumi, Tae ;
Araie, Makoto ;
Tomidokoro, Atsuo ;
Iwase, Aiko ;
Tomita, Goji ;
Yamamoto, Tetsuya .
OPHTHALMOLOGY, 2009, 116 (02) :223-230
[2]  
Anderson D.R., 1999, Automated static perimetry, V2nd
[3]  
Bathija R, 1998, J GLAUCOMA, V7, P121
[4]   ARE LARGE OPTIC-NERVE HEADS SUSCEPTIBLE TO GLAUCOMATOUS DAMAGE AT NORMAL INTRAOCULAR-PRESSURE - A 3-DIMENSIONAL STUDY BY LASER SCANNING TOMOGRAPHY [J].
BURK, ROW ;
ROHRSCHNEIDER, K ;
NOACK, H ;
VOLCKER, HE .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (06) :552-560
[5]   Optic Disc and Retinal Nerve Fiber Layer Thickness Descriptive Analysis in Megalopapilla [J].
Camargos Costa, Alinne Maria ;
Cronemberger, Sebastiao .
JOURNAL OF GLAUCOMA, 2014, 23 (06) :368-371
[6]   Comparison of data analysis tools for detection of glaucoma with the Heidelberg Retina Tomograph [J].
Ford, BA ;
Artes, PH ;
McCormick, TA ;
Nicolela, MT ;
LeBlanc, RP ;
Chauhan, BC .
OPHTHALMOLOGY, 2003, 110 (06) :1145-1150
[7]   The definition and classification of glaucoma in prevalence surveys [J].
Foster, PJ ;
Buhrmann, R ;
Quigley, HA ;
Johnson, GJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (02) :238-242
[8]   Optic disk size and glaucoma [J].
Hoffmann, Esther M. ;
Zangwill, Linda M. ;
Crowston, Jonathan G. ;
Weinreb, Robert N. .
SURVEY OF OPHTHALMOLOGY, 2007, 52 (01) :32-49
[9]   A Test of a Linear Model of Glaucomatous Structure-Function Loss Reveals Sources of Variability in Retinal Nerve Fiber and Visual Field Measurements [J].
Hood, Donald C. ;
Anderson, Susan C. ;
Wall, Michael ;
Raza, Ali S. ;
Kardon, Randy H. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (09) :4254-4266
[10]   The prevalence of primary open-angle glaucoma in Japanese - The Tajimi study [J].
Iwase, A ;
Suzuki, Y ;
Araie, M ;
Yamamoto, T ;
Abe, H ;
Shirato, S ;
Kuwayama, Y ;
Mishima, HK ;
Shimizu, H ;
Tomita, G ;
Inoue, Y ;
Kitazawa, Y .
OPHTHALMOLOGY, 2004, 111 (09) :1641-1648