RL Frequency Response Modeling of Air-cored Reactor

被引:0
作者
Januario, M. [1 ,2 ]
Nunes, A. S. [3 ]
Kuo-Peng, P. [4 ]
Batistela, N. J. [4 ]
机构
[1] Univ Oeste Santa Catarina, UNOESC, Elect Engn Course, Joacaba, SC, Brazil
[2] Univ Fed Santa Catarina, Florianopolis, SC, Brazil
[3] ESSS Engn Simulat & Sci Software, Florianopolis, SC, Brazil
[4] Univ Fed Santa Catarina, BR-88040900 Florianopolis, SC, Brazil
来源
2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM) | 2014年
关键词
Frequency response; Finite Element Method; Least Square; ATP; Air-cored reactor; RATIONAL APPROXIMATION; TRANSIENTS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Considering the importance of modeling the electrical power system behavior under high frequency transients, this paper aims to present a practical methodology to obtain a RL lumped parameters model of an air-cored reactor. Firstly, the RL frequency responses are obtained using the Finite Element Method (FEM). Thus, the frequency response is converted into a RL circuit in accordance with the classical series Foster model and its parameters values are calculated through Least Square (LS) fitting algorithm. Finally, the lumped parameters circuit is converted to an ATP network model. For validation purposes a well-known air-cored reactor is modeled for a frequency range from 10 Hz to 100 kHz and the frequency responses obtained with FEM, LS fitting and ATP are compared.
引用
收藏
页码:2264 / 2269
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 2013, Least squares data fitting with applications
[2]  
Bastos J. P. A., 2003, ELECTROMAGENTIC MODE
[3]   High frequency FEM-based power transformer modeling: Investigation of internal stresses due to network-initiated overvoltages [J].
Bierkan, E. ;
Hoidalen, H. K. .
ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (11) :1483-1489
[4]  
Cabral S. H. L., 2008, MOMAG 2008, V1, P374
[5]   TIME DOMAIN MODELING OF EDDY-CURRENT EFFECTS FOR TRANSFORMER TRANSIENTS [J].
DELEON, F ;
SEMLYEN, A ;
ARTURI, CM ;
NARANG, A ;
DICK, EP .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (01) :271-280
[6]   EFFECTS OF EDDY CURRENTS IN TRANSFORMER WINDINGS [J].
DOWELL, PL .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1966, 113 (08) :1387-&
[7]   Model of laminated iron-core inductors for high frequencies [J].
Grandi, G ;
Kazimierczuk, MK ;
Massarini, A ;
Reggiani, U ;
Sancineto, G .
IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (04) :1839-1845
[8]  
Greenwod A., 1991, ELECT TRANSIENTS POW
[9]  
GROUP A., ALT TRANS BOOK ATP R
[10]   Rational approximation of frequency domain responses by vector fitting [J].
Gustavsen, B ;
Semlyen, A .