Comparison of the fixation ability between lag screw and bone plate for oblique metacarpal shaft fracture

被引:10
作者
Chiu, Yung-Cheng [1 ,2 ]
Ho, Tsung-Yu [2 ]
Hsu, Cheng-En [3 ,4 ]
Ting, Yen-Nien [5 ]
Tsai, Ming-Tzu [6 ]
Hsu, Jui-Ting [7 ,8 ]
机构
[1] China Med Univ, Sch Med, Taichung 404, Taiwan
[2] China Med Univ Hosp, Dept Orthoped Surg, Taichung 404, Taiwan
[3] Taichung Vet Gen Hosp, Dept Orthopaed, Taichung 407, Taiwan
[4] Tunghai Univ, Sports Recreat & Hlth Management Continuing Studi, Taichung 407, Taiwan
[5] China Med Univ Hosp, 3D Printing Med Res Ctr, Taichung 404, Taiwan
[6] Hungkuang Univ, Dept Biomed Engn, Taichung 433, Taiwan
[7] China Med Univ, Coll Dent, Sch Dent, 91 Hsueh Shih Rd, Taichung 40402, Taiwan
[8] Asia Univ, Dept Bioinformat & Med Engn, Taichung 413, Taiwan
关键词
Oblique metacarpal shaft fracture; Screw; Regular plate; Locked plate; INTERNAL-FIXATION; PHALANGEAL;
D O I
10.1186/s13018-022-02963-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background For oblique metacarpal shaft fracture, if anatomical reduction is achieved through conservative cast immobilization rather than stable fixation, bone malrotation can easily occur, resulting in severe loss in hand prehensile function. However, whether bone plate fixation or only lag screw fixation is more preferable remains unclear. Few studies have evaluated whether screw fixation can provide biomechanical fixation strength similar to bone plate fixation. Objective We assessed the difference in fixation strength between fixtation with two lag screws and bone plate for oblique metacarpal shaft fractures. Materials and methods We created oblique metacarpal shaft fractures on 21 artificial bones and fixated them using (1) double lag screw (2LS group), (2) regular plate (RP group), or (3) locked plate (LP group). To obtain the force-displacement data, a cantilever bending test was conducted for each specimen through a material testing machine. One-way analysis of variance and a Tukey test were conducted to compare the maximum fracture force and stiffness of the three fixation methods. Results The maximum fracture force of the 2LS group (mean + SD: 153.6 +/- 26.5 N) was significantly lower than that of the RP (211.6 +/- 18.5 N) and LP (227.5 +/- 10.0 N) groups (p < 0.001). However, no significant differences were discovered between the RP and LP groups. The coefficient of variation for the maximum fracture force of the 2LS group (17.3%) was more than twice as high as that of the RP (8.7%) and LP (4.4%) groups. In addition, the stiffness of the three fixation methods was similar. Conclusion Compared with bone plate fixation, double lag screw fixation yielded slightly lower maximum bearable fracture force but similar stiffness. Therefore, this technique could be used for treating oblique metacarpal shaft fractures. However, using double lag screw fixation alone is technically demanding and requires considerable surgical experiences to produce consistent results.
引用
收藏
页数:6
相关论文
共 24 条
[1]   Results of surgical treatment in metacarpal shaft fractures using low profile mini plates [J].
Aykut, Serkan ;
Ozturk, Kahraman ;
Ozcan, Cagri ;
Demiroglu, Murat ;
Gurun, Ahmet Utku ;
Ozden, Erdem .
ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2015, 21 (04) :279-284
[2]  
Barr Cameron, 2013, Hand (N Y), V8, P454, DOI 10.1007/s11552-013-9544-3
[3]   COMPARISON OF INTERNAL-FIXATION TECHNIQUES IN METACARPAL FRACTURES [J].
BLACK, D ;
MANN, RJ ;
CONSTINE, R ;
DANIELS, AU .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1985, 10A (04) :466-472
[4]   Comparison of the fixation ability of headless compression screws and locking plate for metacarpal shaft transverse fracture [J].
Chiu, Yung-Cheng ;
Hsu, Cheng-En ;
Ho, Tsung-Yu ;
Ting, Yen-Nien ;
Wei, Bor-Han ;
Tsai, Ming-Tzu ;
Hsu, Jui-Ting .
MEDICINE, 2021, 100 (39) :E27375
[5]   Bone plate fixation ability on the dorsal and lateral sides of a metacarpal shaft transverse fracture [J].
Chiu, Yung-Cheng ;
Hsu, Cheng-En ;
Ho, Tsung-Yu ;
Ting, Yen-Nien ;
Tsai, Ming-Tzu ;
Hsu, Jui-Ting .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
[6]   Effect of oblique headless compression screw fixation for metacarpal shaft fracture: a biomechanical in vitro study [J].
Chiu, Yung-Cheng ;
Ho, Tsung-Yu ;
Ting, Yen-Nien ;
Tsai, Ming-Tzu ;
Huang, Heng-Li ;
Hsu, Cheng-En ;
Hsu, Jui-Ting .
BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
[7]   New fixation approach for transverse metacarpal neck fracture: a biomechanical study [J].
Chiu, Yung-Cheng ;
Tsai, Ming-Tzu ;
Hsu, Cheng-En ;
Hsu, Horng-Chaung ;
Huang, Heng-Li ;
Hsu, Jui-Ting .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
[9]   Fixation of Metacarpal Shaft Fractures: Biomechanical Comparison of Intramedullary Nail Crossed K-Wires and Plate-Screw Constructs [J].
Curtis, Benjamin D. ;
Fajolu, Olukemi ;
Ruff, Michael E. ;
Litsky, Alan S. .
ORTHOPAEDIC SURGERY, 2015, 7 (03) :256-260
[10]  
Dreyfuss Daniel, 2019, Hand (N Y), V14, P27, DOI [10.1177/1558944718798854, 10.1177/1558944718798854]