Inkjet-printed disposable metal complexing indicator-displacement assay for sulphide determination in water

被引:28
作者
Ariza-Avidad, M. [1 ]
Agudo-Acemel, M. [1 ]
Salinas-Castillo, A. [1 ]
Capitan-Vallvey, L. F. [1 ]
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, ECsens, E-18071 Granada, Spain
关键词
Sulphide determination; Water analysis; Metal complexing indicator-displacement assay; H coordinate; Digital camera; Inkjet printing; HYDROGEN-SULFIDE; COLORIMETRIC DETECTION; FLUORESCENT-PROBES; RELAY RECOGNITION; BULK OPTODES; SENSOR; ANION; IONS; 1-(2'-PYRIDYLAZO)-2-NAPHTHOL; 1-(2-PYRIDYLAZO)-2-NAPHTHOL;
D O I
10.1016/j.aca.2015.02.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sulphide selective colorimetric metal complexing indicator-displacement assay has been developed using an immobilized copper(II) complex of the azo dye 1-(2-pyridylazo)-2-naphthol printed by inkjetting on a nylon support. The change in colour measured from the image of the disposable membrane acquired by a digital camera using the H coordinate of the HSV colour space as the analytical parameter is able to sense sulphide in aqueous solution at pH 7.4 with a dynamic range up to 145 mu M, a detection limit of 0.10 mu m and a precision between 2 and 11%. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 58 条
[1]   Self association in the structures of two copper(II)-Azo-dye complexes [J].
Adams, H ;
Bucknall, RM ;
Fenton, DE ;
Garcia, M ;
Oakes, J .
POLYHEDRON, 1998, 17 (23-24) :4169-4177
[2]   Poly(vinyl chloride)-membrane ion-selective bulk optode based on 1,10-dibenzyl-1,10-diaza-18-crown-6 and 1-(2-pyridylazo)-2-naphthol for Cu2+ and Pb2+ ions [J].
Alizadeh, N ;
Moemeni, A ;
Shamsipur, M .
ANALYTICA CHIMICA ACTA, 2002, 464 (02) :187-196
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]  
Beer PD, 2001, ANGEW CHEM INT EDIT, V40, P486, DOI 10.1002/1521-3773(20010202)40:3<486::AID-ANIE486>3.3.CO
[6]  
2-G
[7]   Use of the Hue Parameter of the Hue, Saturation, Value Color Space As a Quantitative Analytical Parameter for Bitonal Optical Sensors [J].
Cantrell, K. ;
Erenas, M. M. ;
de Orbe-Paya, I. ;
Capitan-Vallvey, L. F. .
ANALYTICAL CHEMISTRY, 2010, 82 (02) :531-542
[8]  
Capitan-Vallvey L.F., 2003, INTEGRATED ANAL SYST
[9]   Logit linearization of analytical response curves in optical disposable sensors based on coextraction for monovalent anions [J].
Capitán-Vallvey, LF ;
Arroyo-Guerrero, E ;
Fernández-Ramos, MD ;
Cuadros-Rodríguez, L .
ANALYTICA CHIMICA ACTA, 2006, 561 (1-2) :156-163
[10]   Fluorescent probe for highly selective and sensitive detection of hydrogen sulfide in living cells and cardiac tissues [J].
Chen, Bifeng ;
Li, Wei ;
Lv, Cong ;
Zhao, Manman ;
Jin, Hongwei ;
Jin, Hongfang ;
Du, Junbao ;
Zhang, Liangren ;
Tang, Xinjing .
ANALYST, 2013, 138 (03) :946-951