Malfunctioning and Infected Tunneled Infusion Catheters: Over-the-Wire Catheter Exchange versus Catheter Removal and Replacement

被引:12
作者
Guttmann, David M. [1 ]
Trerotola, Scott O. [1 ]
Clark, Timothy W. [1 ]
Dagli, Mandeep [1 ]
Shlansky-Goldberg, Richard D. [1 ]
Itkin, Maxim [1 ]
Soulen, Michael C. [1 ]
Mondschein, Jeffrey I. [1 ]
Stavropoulos, S. William [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Div Intervent Radiol, Philadelphia, PA 19104 USA
关键词
CENTRAL VENOUS CATHETERS; DIALYSIS CATHETERS; MANAGEMENT; THROMBOSIS; PLACEMENT;
D O I
10.1016/j.jvir.2011.01.440
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the safety and effectiveness of over-the-wire catheter exchange (catheter-exchange) with catheter removal and replacement (removal-replacement) at a new site for infected or malfunctioning tunneled infusion catheters. Materials and Methods: Using a quality assurance database, 61 patients with tunneled infusion catheters placed during the period July 2001 to June 2009 were included in this study. Patients receiving hemodialysis catheters were excluded. Catheter-exchange was performed in 25 patients, and same-day removal-replacement was performed in 36 patients. Data collected included demographic information, indication for initial catheter placement and replacement, dwell time for the new catheter, and ultimate fate of the new device. Statistical comparisons between the two cohorts were analyzed using the Kaplan-Meier technique and Fisher exact test. Results: Catheters exchanged over the wire remained functional without infection for a median of 102 days (range, 2-570 days), whereas catheters removed and replaced were functional for a median 238 days (range, 1-292 days, P = .12). After catheter replacement, there were 11 instances of subsequent infection in the catheter-exchange group and 7 instances in the removal-replacement cohort, accounting for infection rates of 4.4 and 2.3 per 1,000 catheter days (P=.049). Patients in the catheter-exchange group had 3.2 greater odds of infection compared with patients in the removal-replacement group. Five malfunction events occurred in each group, accounting for 2.0 and 1.7 malfunctions per 1,000 catheter days in the catheter-exchange and removal-replacement groups (P=.73). Conclusions: Catheter-exchange of tunneled infusion catheters results in a higher infection rate compared with removal-replacement at a new site. The rate of catheter malfunction is not significantly different between the two groups. Catheter-exchange is an alternative for patients with tunneled infusion catheters who have limited venous access, but this technique should not be expanded for use in all patients. Because of the size of this initial study, further investigation is needed to verify the results in a larger sample size.
引用
收藏
页码:642 / 646
页数:5
相关论文
共 19 条
  • [1] Management of occlusion and thrombosis associated with long-term indwelling central venous catheters
    Baskin, Jacquelyn L.
    Pui, Ching-Hon
    Reiss, Ulrike
    Wilimas, Judith A.
    Metzger, Monika L.
    Ribeiro, Raul C.
    Howard, Scott C.
    [J]. LANCET, 2009, 374 (9684) : 159 - 169
  • [2] Beathard GA, 1999, J AM SOC NEPHROL, V10, P1045
  • [3] Quality Improvement Guidelines for Central Venous Access
    Dariushnia, Sean R.
    Wallace, Michael J.
    Siddiqi, Nasir H.
    Towbin, Richard B.
    Wojak, Joan C.
    Kundu, Sanjoy
    Cardella, John F.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (07) : 976 - 981
  • [4] Percutaneous fibrin sheath stripping versus transcatheter urokinase infusion for malfunctioning well-positioned tunneled central venous dialysis catheters: A prospective, randomized trial
    Gray, RJ
    Levitin, A
    Buck, D
    Brown, LC
    Sparling, YH
    Jablonski, KA
    Fessahaye, A
    Gupta, AK
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (09) : 1121 - 1129
  • [5] Do simultaneous bilateral tunneled infusion catheters in patients undergoing bone marrow transplantation increase catheter-related complications?
    Kaufman, LJ
    Clark, TWI
    Roberts, DA
    Freiman, DB
    Shlansky-Goldberg, RD
    Patel, AA
    Mondschein, JI
    Stavropoulos, SW
    Soulen, MC
    Solomon, JA
    Tuite, CM
    Cope, C
    Porter, DL
    Stadtmauer, EA
    Cunningham, KA
    Trerotola, SO
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (01) : 57 - 61
  • [6] Outcome of polyester cuff retention following traction removal of tunneled central venous catheters
    Kohli, MD
    Trerotola, SO
    Namyslowski, J
    Stecker, MS
    McLennan, G
    Patel, NH
    Johnson, MS
    Shah, H
    Seshadri, R
    [J]. RADIOLOGY, 2001, 219 (03) : 651 - 654
  • [7] Comparison of complications between transjugular and axillosubclavian approach for placement of tunneled, central venous catheters in patients with hematological malignancy: a prospective study
    Lee, SH
    Hahn, ST
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (06) : 1100 - 1104
  • [8] The risk of bloodstream infection in adults with different intravascular devices: A systematic review of 200 published prospective studies
    Maki, Dennis G.
    Kluger, Daniel M.
    Crnich, Christopher J.
    [J]. MAYO CLINIC PROCEEDINGS, 2006, 81 (09) : 1159 - 1171
  • [9] *NAT KIDN FDN, 2006, AM J KIDNEY DIS S, V48, pS248
  • [10] Naufel D, 2009, J VASC INTERV RADIOL, V20, pS126