Multienzyme-modified biosensing surface for the electrochemical analysis of aspartate transaminase and alanine transaminase in human plasma

被引:53
作者
Han, Yong Duk [1 ]
Song, Seung Yeon [1 ]
Lee, Jun Hwang [1 ]
Lee, Dae Sik [2 ]
Yoon, Hyun C. [1 ]
机构
[1] Ajou Univ, Dept Mol Sci & Technol, Suwon 443749, South Korea
[2] ETRI, BT Convergence Technol Res Lab, Taejon 305700, South Korea
基金
新加坡国家研究基金会;
关键词
Electrochemical biosensor; Immobilized enzyme surface; Clinical enzyme analysis; Multienzyme assay; CATALYTIC ACTIVITY CONCENTRATIONS; GLUTAMATE PYRUVATE TRANSAMINASE; ACUTE MYOCARDIAL-INFARCTION; CORONARY-HEART-DISEASE; LACTOBACILLUS-PLANTARUM; CONDUCTING POLYMER; OXIDASE; AMINOTRANSFERASE; ELECTRODE; ENZYME;
D O I
10.1007/s00216-011-4797-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We investigated the electrochemical detection of aspartate transaminase (AST) and alanine transaminase (ALT) by using a multienzyme-modified electrode surface. Determination of the activities of transaminases in human serum is clinically significant because their concentrations and ratios indicate the presence of hepatic diseases or myocardial dysfunction. For electrochemical detection of AST and ALT, enzymes that participate in the reaction mechanism of AST and ALT, such as pyruvate oxidase (POX) and oxaloacetate decarboxylase, were immobilized on an electrode surface by using an amine-reactive self-assembled monolayer and a homobifunctional cross-linker. In the presence of suitable substrates such as l-aspartate (l-alanine) and alpha-ketoglutarate, AST and ALT generate pyruvate as an enzymatic end product. To determine the activities of AST and ALT, electroanalyses of pyruvate were conducted using a POX and ferrocenemethanol electron shuttle. Anodically generated oxidative currents from multienzyme-mediated reactions were correlated to AST and ALT levels in human plasma. On the basis of the electrochemical analysis, we obtained calibration results for AST and ALT concentrations from 7.5 to 720 units/L in human plasma-based samples, covering the required clinical detection range.
引用
收藏
页码:797 / 805
页数:9
相关论文
共 34 条
  • [1] A novel biosensor based on activation effect of thiamine on the activity of pyruvate oxidase
    Akyilmaz, Erol
    Yorganci, Emine
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (12) : 1874 - 1877
  • [2] Pyruvate sensor based on pyruvate oxidase immobilized in a poly(mercapto-p-benzoquinone) film
    Arai, G
    Noma, T
    Habu, H
    Yasumori, I
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 464 (02): : 143 - 148
  • [3] Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor
    Arya, Sunil K.
    Pandey, Pratibha
    Singh, Surinder P.
    Datta, Monika
    Malhotra, Bansi D.
    [J]. ANALYST, 2007, 132 (10) : 1005 - 1009
  • [4] Determination of glutamate pyruvate transaminase activity in clinical specimens using a biosensor composed of immobilized L-glutamate oxidase in a photo-crosslinkable polymer membrane on a palladium-deposited screen-printed carbon electrode
    Chang, KS
    Hsu, WL
    Chen, HY
    Chang, CK
    Chen, CY
    [J]. ANALYTICA CHIMICA ACTA, 2003, 481 (02) : 199 - 208
  • [5] Molecular assembly of multilayer enzyme: Toward the development of a chemiluminescence-based fiber optic biosensor
    Chen, ZP
    Kaplan, DL
    Gao, H
    Kumar, J
    Marx, KA
    Tripathy, SK
    [J]. MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC MATERIALS SENSORS AND SYSTEMS, 1996, 4 (03): : 155 - 159
  • [6] Reagentless recycling of pyruvate oxidase on a conducting polymer-modified electrode
    Dang, L. A.
    Haccoun, J.
    Piro, B.
    Pham, M. C.
    [J]. ELECTROCHIMICA ACTA, 2006, 51 (19) : 3934 - 3943
  • [7] Dufour DR, 2000, CLIN CHEM, V46, P2027
  • [8] Gajovic N, 1999, ELECTROANAL, V11, P1377, DOI 10.1002/(SICI)1521-4109(199912)11:18<1377::AID-ELAN1377>3.3.CO
  • [9] 2-2
  • [10] Operation of a miniature redox hydrogel-based pyruvate sensor in undiluted deoxygenated calf serum
    Gajovic, N
    Binyamin, G
    Warsinke, A
    Scheller, FW
    Heller, A
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (13) : 2963 - 2968