Behavior and Modeling of Hybrid CFRP/Steel Reinforced Concrete Beams with Cathodic Protection in a Marine Environment

被引:5
作者
Huang, Xiaoxu [1 ]
Zhou, Yingwu [1 ]
Zheng, Xubin [1 ]
Lan, Youbin [1 ]
Xing, Feng [1 ]
Sui, Lili [1 ]
Hu, Biao [1 ]
Li, Shan [2 ]
机构
[1] Shenzhen Univ, Guangdong Prov Key Lab Durabil Marine Civil Engn, Shenzhen 518060, Peoples R China
[2] Wuhan Univ, Sch Civil Engn, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Corrosion; Cathodic protection; Hybrid reinforcement; CFRP bar; Flexural performance; STEEL BARS; FLEXURAL BEHAVIOR; CORROSION; EVOLUTION; POLYMER; ANODES; BOND;
D O I
10.1061/(ASCE)CC.1943-5614.0001266
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Impressed current cathodic protection (ICCP) has been proven to be an effective technique to inhibit steel corrosion. Based on the principle of ICCP, a hybrid carbon fiber-reinforced polymer (CFRP)/steel reinforced concrete (RC) structural system with cathodic protection has been proposed considering the dual function of CFRP, namely, the anode material of ICCP and reinforcement of concrete structures at the same time. For this system, the larger structural deflection and brittle failure caused by the low elastic modulus and linear elastic behavior of the CFRP bar can be avoided, and ICCP is activated only when the steel bar is at risk for corrosion. In this paper, the flexural performance of the proposed structural system with different reinforcement configurations was investigated. First, an accelerated precorrosion test was conducted for the steel bar with a theoretical corrosion ratio of 8%. Then, wet-dry cycle corrosion was performed by companies with ICCP treatment for 150 and 180 days. Finally, four-point bending tests were carried out, followed by a comparison of the experimental bending capacities and predicted values. The results showed that for the proposed structural system, the further corrosion of steel bars was inhibited significantly with a protection current density of 10 mA/m(2), leading to the maintenance of satisfactory structural performance without a marked deterioration of the CFRP anode performance or the CFRP-concrete bond behavior. The reinforcement configuration with CFRP bars in the lower row and steel bars in the upper row was the most effective to maintain a satisfying bending capacity and inhibit steel corrosion for the proposed structural system in a corrosive environment.
引用
收藏
页数:15
相关论文
共 58 条
  • [1] Challenges and opportunities in corrosion of steel in concrete
    Angst, Ueli M.
    [J]. MATERIALS AND STRUCTURES, 2018, 51 (01)
  • [2] [Anonymous], 2017, G103 ASTM INT
  • [3] ASCE, 2021, Infrastruct Rep Card ASCE USA
  • [4] ASTM, 2015, C87615 ASTM, DOI [10.1520/C0876-15, DOI 10.1520/C0876-15]
  • [5] Impressed current cathodic protection of rebar in concrete using Carbon FRP laminate
    Bahekar, Prasad V.
    Gadve, Sangeeta S.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 156 : 242 - 251
  • [6] BSI (British Standards Institution), 2019, 12954 BS EN
  • [7] Chen E., 2020, PROC RILEM FIB INT S, P477
  • [8] Active Protection of Fiber-Reinforced Polymer-Wrapped Reinforced Concrete Structures Against Corrosion
    Gadve, S.
    Mukherjee, A.
    Malhotra, S. N.
    [J]. CORROSION, 2011, 67 (02) : 0250021 - 02500211
  • [9] GB (Guobiao Standards), 2010, 2282010 GBT GEN ADM
  • [10] GB (Guobiao Standards), 2019, 500812019 GBT