Minimally invasive Oxford phase 3 unicompartmental knee replacement RESULTS OF 1000 CASES

被引:259
|
作者
Pandit, H. [1 ]
Jenkins, C. [2 ]
Gill, H. S. [1 ]
Barker, K. [2 ]
Dodd, C. A. F. [2 ]
Murray, D. W. [1 ]
机构
[1] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford OX1 2JD, England
[2] Nuffield Orthopaed Ctr, Oxford OX3 7LD, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2011年 / 93B卷 / 02期
关键词
ANTERIOR CRUCIATE RECONSTRUCTION; ARTHROPLASTY; PROSTHESIS;
D O I
10.1302/0301-620X.93B2.25767
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This prospective study describes the outcome of the first 1000 phase 3 Oxford medial unicompartmental knee replacements (UKRs) implanted using a minimally invasive surgical approach for the recommended indications by two surgeons and followed up independently. The mean follow-up was 5.6 years (1 to 11) with 547 knees having a minimum follow-up of five years. At five years their mean Oxford knee score was 41.3 (SD 7.2), the mean American Knee Society Objective Score 86.4 (SD 13.4), mean American Knee Society Functional Score 86.1 (SD 16.6), mean Tegner activity score 2.8 (SD 1.1). For the entire cohort, the mean maximum flexion was 130 degrees at the time of final review. The incidence of implant-related re-operations was 2.9%; of these 29 re-operations two were revisions requiring revision knee replacement components with stems and wedges, 17 were conversions to a primary total knee replacement, six were open reductions for dislocation of the bearing, three were secondary lateral UKRs and one was revision of a tibial component. The most common reason for further surgical intervention was progression of arthritis in the lateral compartment (0.9%), followed by dislocation of the bearing (0.6%) and revision for unexplained pain (0.6%). If all implant-related re-operations are considered failures, the ten-year survival rate was 96% (95% confidence interval, 92.5 to 99.5). If only revisions requiring revision components are considered failures the ten-year survival rate is 99.8% (confidence interval 99 to 100). This is the largest published series of UKRs implanted through a minimally invasive surgical approach and with ten-year survival data. The survival rates are similar to those obtained with a standard open approach whereas the function is better. This demonstrates the effectiveness and safety of a minimally invasive surgical approach for implanting the Oxford UKR.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 50 条
  • [31] The management of mobile bearing dislocation in the Oxford lateral unicompartmental knee replacement
    Weston-Simons, John S.
    Pandit, H.
    Gill, H. S.
    Jackson, W. F. M.
    Price, A. J.
    Dodd, C. A. F.
    Murray, D. W.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (12) : 2023 - 2026
  • [32] Cementless medial Oxford unicompartmental knee replacement. Five-year results from an independent series
    Hefny, Mamdouh H.
    Smith, Nick A.
    Waite, Jon
    KNEE, 2020, 27 (04) : 1219 - 1227
  • [33] Results of Unicompartmental Knee Arthroplasty With Cemented, Fixed-Bearing Prosthesis Using Minimally Invasive Surgery
    Biswal, Sandeep
    Brighton, Roger W.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (05) : 721 - 727
  • [34] Minimally invasive small incision surgical technique for unicompartmental knee arthroplasty
    Ge, Juncheng
    Hernigou, Philippe
    Guo, Wanshou
    Zhang, Nianfei
    Liu, Changquan
    Zhang, Qidong
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (11) : 2717 - 2725
  • [35] The mid-term outcomes of the Oxford Domed Lateral unicompartmental knee replacement
    Weston-Simons, J. S.
    Pandit, H.
    Kendrick, B. J. L.
    Jenkins, C.
    Barker, K.
    Dodd, C. A. F.
    Murray, D. W.
    BONE & JOINT JOURNAL, 2014, 96B (01) : 59 - 64
  • [36] Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year
    Pandit, H.
    Jenkins, C.
    Beard, D. J.
    Gallagher, J.
    Price, A. J.
    Dodd, C. A. F.
    Goodfellow, J. W.
    Murray, D. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (02): : 185 - 189
  • [37] Minimally Invasive Unicompartmental Knee Arthroplasty Using Intramedullary Femoral Alignment
    Della Valle, Craig J.
    Berger, Richard A.
    Rosenberg, Aaron G.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2006, 16 (03) : 186 - 194
  • [38] Medial femoral condyle fracture as an intraoperative complication of Oxford unicompartmental knee replacement
    ten Brinke, Bart
    de Haan, Laurens J.
    Koenraadt, Koen L. M.
    van Geenen, Rutger C. I.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (10) : 3191 - 3193
  • [39] Minimally Invasive Robotic-Arm-Guided Unicompartmental Knee Arthroplasty
    Conditt, Michael A.
    Roche, Martin W.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 63 - 68
  • [40] Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty A comparison with a conventional instrumented technique
    Jung, Kwang Am
    Kim, Sung Jae
    Lee, Su Chan
    Hwang, Seung Hyun
    Ahn, Nong Kyoum
    KNEE, 2010, 17 (06) : 387 - 391