Development of Simultaneous Detection of Total Prostate-Specific Antigen (tPSA) and Free PSA With Rapid Bead-Based Immunoassay

被引:20
作者
Xie, Chong [1 ]
Wang, Guomin [1 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Urol, Shanghai 200032, Peoples R China
关键词
tumor marker; luminex assay; prostate cancer; prostate-specific antigen; simultaneous detection; CANCER DETECTION; COMPLEXED PSA; ASSAYS; FORMS; ALPHA-1-ANTICHYMOTRYPSIN; DISEASE; BENIGN; TRIAL; NG/ML; RATIO;
D O I
10.1002/jcla.20427
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: Prostate-specific antigen (PSA) is the most important biochemical tumor marker for the early detection of prostate cancer; however, its diagnostic specificity is low. Therefore, free PSA (fPSA) test is recommended as an adjunct to increase the specificity. However, all the current technology only allows detecting one biomarker at one time. In this study, we reported a flexible bead-based immunoassay to measure total PSA (tPSA) and fPSA simultaneously. Materials and Methods: We used the Luminex xMAP bead array technology to measure tPSA and fPSA at one time, employing two mouse monoclonal anti-PSA antibodies (5G6 and 8A6) for coating and another mouse monoclonal anti-PSA antibody (5A6) for detection. Then we compared the data of Luminex assay with that of the conventional enzyme-linked immunosorbent assay (ELISA). Results The assay was fast with a wide dynamic range. The lower detection limit for tPSA and fPSA were 2.3 and 1.3 pg/ml. The inter-assay coefficients for tPSA and fPSA were between 5.64 and 7.65%, and the intra-assay coefficients for tPSA and fPSA were between 4.15 and 5.89%. A close correlation between the new assay and the conventional ELISA was observed. Conclusions The bead-based platform is rapid, sensitive, and less expensive, which allows both single sample and high-throughput measurement of tPSA and fPSA over a wide range of concentrations. J. Clin. Lab. Anal. 25:37-42, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 21 条
[1]  
Björk T, 1999, BJU INT, V84, P1021
[2]   The f/t-PSA ratio in diagnosis of in-patients and out-patients: a unitary cutoff value is not useful! [J].
Boergermann, C. ;
Swoboda, A. ;
Luboldt, H. -J. ;
vom Dorp, F. ;
Ruebben, H. .
WORLD JOURNAL OF UROLOGY, 2009, 27 (05) :581-585
[3]   Monoclonal antibodies 2F5 and 4G10 against prostate specific antigen (PSA) complexed to α1-antichymotrypsin [J].
Chen, ZX ;
Chen, HB ;
Stamey, TA .
JOURNAL OF UROLOGY, 1998, 160 (03) :870-875
[4]   Simultaneous detection of free and total prostate specific antigen on a screen-printed electrochemical dual sensor [J].
Escamilla-Gomez, Vanessa ;
Hernandez-Santos, David ;
Begona Gonzalez-Garcia, Maria ;
Manuel Pingarron-Carrazon, Jose ;
Costa-Garcia, Agustin .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) :2678-2683
[5]   Comparison of the clinical value of complexed PSA and total PSA in the discrimination between benign prostatic hyperplasia and prostate cancer [J].
Froehner, M ;
Hakenberg, OW ;
Koch, R ;
Schmidt, U ;
Meye, A ;
Wirth, MP .
UROLOGIA INTERNATIONALIS, 2006, 76 (01) :27-30
[6]   Multiplex microsphere-based flow cytometric platforms for protein analysis and their application in clinical proteomics - from assays to results [J].
Hsu, Hsin-Yun ;
Joos, Thomas O. ;
Koga, Hisashi .
ELECTROPHORESIS, 2009, 30 (23) :4008-4019
[7]   False-positive screening results in the Finnish prostate cancer screening trial [J].
Kilpelainen, T. P. ;
Tammela, T. L. J. ;
Maattanen, L. ;
Kujala, P. ;
Stenman, U-H ;
Ala-Opas, M. ;
Murtola, T. J. ;
Auvinen, A. .
BRITISH JOURNAL OF CANCER, 2010, 102 (03) :469-474
[8]   Improved Luminex-based human leukocyte antigen-specific antibody screening using dithiothreitol-treated sera [J].
Kosmoliaptsis, Vasilis ;
O'Rourke, Cheryl ;
Bradley, J. Andrew ;
Taylor, Craig J. .
HUMAN IMMUNOLOGY, 2010, 71 (01) :45-49
[9]   Comparative study of assays for prostate-specific antigen molecular forms [J].
Kuriyama, M ;
Uno, H ;
Ueno, K ;
Hamamoto, Y ;
Vihn, PQ ;
Ban, Y .
JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 1999, 29 (06) :303-307
[10]   Cascade enzyme-linked immunosorbent assay (CELISA) [J].
Lee, Young-mi ;
Jeong, Yujin ;
Kang, Hyo Jin ;
Chung, Sang J. ;
Chung, Bong Hyun .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (02) :332-337