Visual outcome and optical quality of a wavefront-engineered extended depth-of-focus intraocular lens

被引:7
|
作者
Greve, Daria [1 ]
Bertelmann, Eckart [2 ]
Pilger, Daniel [2 ]
von Sonnleithner, Christoph [2 ]
机构
[1] Vivantes Neukolln, Dept Ophthalmol, Berlin, Germany
[2] Charite Med Univ, Dept Ophthalmol, Campus Virchow,Augustenburger Pl 1, D-13353 Berlin, Germany
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2021年 / 47卷 / 09期
关键词
PERFORMANCE; IMPLANTATION; ABERRATION;
D O I
10.1097/j.jcrs.0000000000000604
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate visual performance and optical quality of an extended depth-of-focus intraocular lens (EDoF IOL) compared with a monofocal aspheric IOL. Setting: Department of Ophthalmology, Charit acute accent e-Medical University Berlin, Germany. Design: Prospective case series. Methods: After phacoemulsification, a total of 28 patients (56 eyes) underwent bilateral implantation of either the Mini Well (EDoF IOL) or the Mini 4 (monofocal IOL). Assessments including refraction, distance, intermediate and near visual acuity, defocus curves, contrast sensitivity, glare disability, higher-order aberrations (HOAs), and patient satisfaction were performed at 1 month and 3 months postoperatively. Results: Both study groups comprised 14 patients (28 eyes) each. At 3-month follow-up, the EDoF IOL showed better results in monocular uncorrected intermediate visual acuity (-0.04 vs 0.10 logMAR, P = .000) and in uncorrected near visual acuity (0.13 vs 0.36 logMAR, P = .000), whereas no statistically significant difference was found between groups in monocular uncorrected distance visual acuity (0.04 vs 0.00 logMAR, P = .110). The monocular depth of focus was 0.8 D greater in the Mini Well IOL group. Measurements of internal HOAs revealed a greater negative primary spherical aberration in the EDoF group at pupil sizes of 2.0 to 5.0 mm. At 5.0 mm, total internal HOAs did not differ statistically significantly (0.376 vs 0.340 mm root mean square, P = .068). Conclusions: The Mini Well IOL provided greater depth of focus with superior outcomes at intermediate and near distances and comparable outcomes at far distance. Although inducing higher amounts of spherical aberration, it showed good results under low lighting conditions with little subjective dysphotopsia.
引用
收藏
页码:1139 / 1146
页数:8
相关论文
共 50 条
  • [21] Visual outcomes and patient satisfaction after implantation of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and multifocal profiles
    Ribeiro, Filomena J.
    Ferreira, Tiago B.
    Silva, Diana
    Matos, Ana Claudia
    Gaspar, Sylvia
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (11): : 1448 - 1453
  • [22] Results of an Extended Depth-of-Focus Intraocular Lens Implantation in the Second Eye of Monofocal Pseudophakic Patients: A Pilot Study
    Shemesh, Rachel
    Reitblat, Olga
    Rodov, Luba
    Levy, Adi
    Assia, Ehud I.
    Kleinmann, Guy
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2023, 12 (04): : 349 - 354
  • [23] Extended depth of focus intraocular lens: chromatic performance
    Millan, Maria S.
    Vega, Fidel
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (09): : 4294 - 4309
  • [24] Visual function in eyes with diffractive extended depth-of-focus and monofocal intraocular lenses: 2-year comparison
    Hisai, Takahiro
    Takada, Keita
    Tokuda, Shota
    Nejima, Ryohei
    Mori, Yosai
    Minami, Keiichiro
    Miyata, Kazunori
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (09) : 2567 - 2573
  • [25] The Postoperative Visual and Refractive Outcomes of Trifocal and Extended Depth-of-Focus Intraocular Lenses in Patients with Different Biometric Characteristics
    Lee, Chia-Yi
    Chen, Hung-Chi
    Lian, Ie-Bin
    Huang, Jing-Yang
    Yang, Shun-Fa
    Chang, Chao-Kai
    DIAGNOSTICS, 2024, 14 (16)
  • [26] Optical and clinical simulated performance of a new refractive extended depth of focus intraocular lens
    Alarcon, Aixa
    Carrasco, Antonio del Aguila
    Gounou, Franck
    Weeber, Henk
    Canovas, Carmen
    Piers, Patricia
    EYE, 2024, 38 (SUPPL 1) : 4 - 8
  • [27] Visual Performance, Subjective Satisfaction and Quality of Life Effect of a New Refractive Intraocular Lens with Central Extended Depth of Focus
    Gillmann, Kevin
    Mermoud, Andre
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (04) : 384 - 390
  • [28] Evaluation of the Functional Visual Range of a Catenary Curve-Based, Extended Depth-of-Focus Contact Lens for Presbyopia
    Tuan, K. Ashley
    Benoit, Douglas P.
    OConnor, Brett
    CLINICAL OPHTHALMOLOGY, 2024, 18
  • [29] Measuring Defocus Curves of Monofocal, Multifocal and Extended Depth-of-focus Intraocular Lenses Using Optical Bench Test
    Koo, Yong Ho
    Lee, Chang Su
    Kim, Jin Soo
    Shin, Min Chul
    Kim, Eun Chul
    Kim, Man Soo
    Hwang, Ho Sik
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (02): : 153 - 158
  • [30] Visual function, ocular surface integrity and symptomatology of a new extended depth-of-focus and a conventional multifocal contact lens
    Martinez-Alberquilla, Irene
    Garcia-Montero, Maria
    Ruiz-Alcocer, Javier
    Crooke, Almudena
    Madrid-Costa, David
    CONTACT LENS & ANTERIOR EYE, 2021, 44 (05):