Unifying energy minimization and mutual information maximization for robust 2D/3D registration of x-ray and CT images

被引:0
|
作者
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, MEM Res Ctr, CH-3014 Bern, Switzerland
来源
PATTERN RECOGNITION, PROCEEDINGS | 2007年 / 4713卷
关键词
similarity measure; mutual information; 2D/3D registration; x-ray; CT; Markov random field; Kullback-Leibler bound;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Similarity measure is one of the main factors that affect the accuracy of intensity-based 2D/3D registration of X-ray fluoroscopy to CT, images. Information theory has been used to derive similarity measure for image registration leading to the introduction of mutual information, an accurate similarity measure for multi-modal and mono-modal image registration tasks. However, it is known that the standard mutual information measure only takes intensity values into account without considering spatial information and its robustness is questionable. Previous attempt to incorporate spatial information into mutual information either requires computing the entropy of higher dimensional probability distributions, or is not robust to outliers. In this paper, we show how to incorporate spatial information into mutual information without suffering from these problems. Using a variational approximation derived from the Kullback-Leibler bound, spatial information can be effectively incorporated into mutual information via energy minimization. The resulting similarity measure has a least-squares form and can be effectively minimized by a multi-resolution Levenberg-Marquardt optimizer. Experimental results are presented on datasets of two applications: (a) intra-operative patient pose estimation from a few (e.g. 2) calibrated fluoroscopic images, and (b) post-operative cup alignment estimation from single X-ray radiograph with gonadal shielding.
引用
收藏
页码:547 / 557
页数:11
相关论文
共 50 条
  • [21] Transfer Learning for Nonrigid 2D/3D Cardiovascular Images Registration
    Guan, Shaoya
    Wang, Tianmiao
    Sun, Kai
    Meng, Cai
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (09) : 3300 - 3309
  • [22] Fully automatic reconstruction of personalized 3D volumes of the proximal femur from 2D X-ray images
    Yu, Weimin
    Chu, Chengwen
    Tannast, Moritz
    Zheng, Guoyan
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (09) : 1673 - 1685
  • [23] Estimation of Cochlear Implant Insertion Depth Using 2D-3D Registration of Postoperative X-Ray and Preoperative CT Images
    Liu, George S.
    Cooperman, Shayna P.
    Neves, Caio A.
    Blevins, Nikolas H.
    OTOLOGY & NEUROTOLOGY, 2024, 45 (03) : e156 - e161
  • [24] Robust and Fast Initialization for Intensity-Based 2D/3D Registration
    Shao, Zhenzhou
    Han, Jianda
    Liang, Wei
    Tan, Jindong
    Guan, Yong
    ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [25] 3D VOLUMETRIC INTENSITY RECONSTURCTION FROM 2D X-RAY IMAGES USING PARTIAL LEAST SQUARES REGRESSION
    Zheng, Guoyan
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1268 - 1271
  • [26] Optimal calibration marker mesh for 2D X-ray sensors in 3D reconstruction
    Desbat, L
    Mennessier, C
    Champleboux, G
    COMPTES RENDUS BIOLOGIES, 2002, 325 (04) : 431 - 438
  • [27] Intra-cardiac 2D US to 3D CT image registration
    Huang, Xishi
    Hill, Nicholas A.
    Ren, Jing
    Guiraudon, Gerard
    Peters, Terry M.
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [28] Evaluation of similarity measures for 3D/2D image registration
    Skerl, Darko
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [29] Adaptive reduction of intensity levels in 3D images for mutual information-based registration
    Castro-Pareja, CR
    Shekhar, R
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 1201 - 1212
  • [30] The geometric modeling for 3D information of X-ray inspection
    Lee, Heung-Ho
    Lee, Seung-Min
    Transactions of the Korean Institute of Electrical Engineers, 2013, 62 (08) : 1151 - 1156