EFFECT OF ARRAY JET ON COOLING EFFECTIVENESS ON FULL-COVERAGE FILM COOLED SURFACE

被引:0
作者
Lee, Dong Hyun [1 ]
Oh, Sang Hyun [1 ]
Jung, Eui Yeop [1 ]
Kim, Kyung Min [1 ]
Cho, Hyung Hee [1 ]
机构
[1] Yonsei Univ, Sch Mech Engn, Seoul 120749, South Korea
来源
HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 2 | 2009年
关键词
HEAT MASS TRANSFER; LOCAL HEAT/MASS TRANSFER; SPENT FLUID REMOVAL; IMPINGING JETS; DISCRETE HOLES; EFFUSION PLATE; TARGET SURFACE; VENT HOLES; INJECTION; SYSTEMS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this study, the cooling effectiveness (phi) was measured on full-coverage film cooled surface with and without array jet impingement cooing using an infra-red thermographic technique. Measurements were conducted with two test plates of different thermal conductivities. One was made of stainless steel (k=16.3 W/m.K) and the other was made of polycarbonate (k=0.2 W/m . K). The measured cooling effectiveness comprises the adiabatic film cooling effectiveness on the film cooled surfaces, the heat conduction through the test plates and convective heat transfer of array jet impingement underneath the test plates. The inclination angles of film cooling holes and impingement jet holes were 35 degrees and 90 degrees, respectively. The diameters of both film cooling and impingement jet cooling holes were 5 mm. The streamwise and spanwise hole spacing-to-hole diameter ratios (p/d) are 3 for both the effusion plate (film cooled plate) and the injection plate (impingement nozzle plate. The holes on each plate were arranged in an inline pattern, while the film cooling holes and jet holes were positioned in a staggered manner. The jet Reynolds number based on the hole diameter was 3,000 and the equivalent blowing ratio (M) was 0.3. The gap distance between the jet plate and the film cooling plate was varied from 1 to 5 times of the hole diameter. In addition, the cooling effectiveness without impingement was tested, too. The stainless steel plate shows relatively higher and uniform cooling effectiveness than the polycarbonate plate. The effect of H/d was not significant for both test plates. However, the cooling effectiveness without the impingement jets decreases significantly for the stainless steel plate, while it changed a little for the cooling effectiveness of the polycarbonate plate.
引用
收藏
页码:565 / 572
页数:8
相关论文
共 25 条
[1]  
Andrews G., 1989, ASME 1989 INT GAS TU
[2]   SMALL DIAMETER FILM COOLING HOLES - WALL CONVECTIVE HEAT-TRANSFER [J].
ANDREWS, GE ;
ALIKHANIZADEH, M ;
ASERE, AA ;
HUSSAIN, CI ;
AZARI, MSK ;
MKPADI, MC .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1986, 108 (02) :283-289
[3]  
ANDREWS GE, 1987, 87GT28 ASME
[4]  
ANDREWS GE, 2002, P 7 IGTC GAS TURB SO, V2, P639
[5]   HEAT (MASS) TRANSFER AND FILM-COOLING EFFECTIVENESS WITH INJECTION THROUGH DISCRETE HOLES .2. ON THE EXPOSED SURFACE [J].
CHO, HH ;
GOLDSTEIN, RJ .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1995, 117 (03) :451-460
[6]   Local heat/mass transfer measurement on the effusion plate in impingement/effusion cooling systems [J].
Cho, HH ;
Rhee, DH .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2001, 123 (03) :601-608
[7]   Total-coverage discrete hole wall cooling [J].
Cho, HH ;
Goldstein, RJ .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1997, 119 (02) :320-329
[8]   HEAT (MASS) TRANSFER AND FILM-COOLING EFFECTIVENESS WITH INJECTION THROUGH DISCRETE HOLES .1. WITHIN HOLES AND ON THE BACK SURFACE [J].
CHO, HH ;
GOLDSTEIN, RJ .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1995, 117 (03) :440-450
[9]  
CHO HH, 2008, ASME, V130
[10]   FULL-COVERAGE FILM COOLING .1. COMPARISON OF HEAT-TRANSFER DATA FOR 3 INJECTION ANGLES [J].
CRAWFORD, ME ;
KAYS, WM ;
MOFFAT, RJ .
JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1980, 102 (04) :1000-1005