Experimental Study on the Importance of Accurate Neutron Angular Distribution Measurement for Determination of Neutron Yield in a 2.5 kJ Mather type PF

被引:0
作者
Bidabadi, Babak Shirani [1 ]
Davani, Fereydoon Abbasi [1 ]
机构
[1] Shahid Beheshti Univ, Radiat Applicat Dept, Tehran, Iran
关键词
Plasma focus; Fusion; Neutron; Activation counter; Calibration; Neutron angular distribution; DENSE-PLASMA FOCUS; PRESSURE; EMISSION;
D O I
10.1007/s10894-010-9297-8
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Three activation counters were constructed by thin wall Geiger and were placed in different angels with respect to anode axis; 0A degrees, 45A degrees, 90A degrees; where the Geigers have 20 cm distance from anode top of the 2.5 kJ SBUPF1 plasma focus device. The counters were calibrated by a 5 Ci Am-Be neutron source with source removal method. A computer program receives the Results of each plasma focus experiment and background count rates, estimates the angular distribution of neutron emission and calculates the neutron yield of each shot. The neutron yield of the device was measured about 6 x 10(7) neutrons per shot. The results, indicate that using three counters (instead of one counter in 0A degrees) in different angles for determination of total neutron yield, gives a more accurate measurement (up to 28% is measured in sample shots), and this error is bigger in those shots that thermonuclear fusion mechanism have greater share in neutron production.
引用
收藏
页码:416 / 420
页数:5
相关论文
共 14 条
[1]   Measurement of angular distribution of neutrons emitted from plasma focus using NTD [J].
Antanasijevic, R ;
Maric, Z ;
Banjanac, R ;
Dragic, A ;
Stanojevic, J ;
Dordevic, D ;
Joksimovic, D ;
Udovicic, V ;
Vukovic, J .
RADIATION MEASUREMENTS, 1999, 31 (1-6) :443-446
[2]   DENSE-PLASMA FOCUS - HIGH-INTENSITY NEUTRON SOURCE [J].
BERNARD, A ;
CLOTH, P ;
CONRADS, H ;
COUDEVILLE, A ;
GOURLAN, G ;
JOLAS, A ;
MAISONNIER, C ;
RAGER, JP .
NUCLEAR INSTRUMENTS & METHODS, 1977, 145 (01) :191-218
[3]   Isotropic and anisotropic components of neutron emissions at the FN-II and PACO dense plasma focus devices [J].
Castillo, F ;
Herrera, JJE ;
Rangel, J ;
Milanese, M ;
Moroso, R ;
Pouzo, J ;
Golzarri, JI ;
Espinosa, G .
PLASMA PHYSICS AND CONTROLLED FUSION, 2003, 45 (03) :289-300
[4]   DENSE-PLASMA FOCUS AS A NEUTRON SOURCE FOR FUSION-RESEARCH [J].
CONRADS, H .
NUCLEAR SCIENCE AND ENGINEERING, 1990, 106 (03) :299-307
[5]   COMPARISON OF 4 CALIBRATION TECHNIQUES OF A SILVER ACTIVATED GEIGER COUNTER FOR THE DETERMINATION OF THE NEUTRON YIELD ON THE FRASCATI PLASMA-FOCUS EXPERIMENT [J].
GENTILINI, A ;
RAGER, JP ;
STEINMETZ, K ;
TACCHI, M ;
ANTONINI, D ;
ARCIPIANI, B ;
MOIOLI, P ;
PEDRETTI, E ;
SCAFE, R .
NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (03) :541-552
[6]   Experimental study of the variation of neutron emission anisotropy in a filippov-type plasma focus facility [J].
Goudarzi, S. ;
Amrollahi, R. ;
Alizadeh, E. .
JOURNAL OF FUSION ENERGY, 2007, 26 (04) :343-347
[7]   Optimization of the high pressure operation regime for enhanced neutron yield in a plasma focus device [J].
Koh, JM ;
Rawat, RS ;
Patran, A ;
Zhang, T ;
Wong, D ;
Springham, SV ;
Tan, TL ;
Lee, S ;
Lee, P .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2005, 14 (01) :12-18
[8]   Conceptual engineering of plasma-focus thermonuclear pulsors [J].
Moreno, C ;
Bruzzone, H ;
Martínez, J ;
Clausse, A .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2000, 28 (05) :1735-1741
[9]   PLASMA FOCUS CURRENT IN COMPRESSION PHASE [J].
OPPENLANDER, T ;
PROSS, G ;
DECKER, G ;
TRUNK, M .
PLASMA PHYSICS AND CONTROLLED FUSION, 1977, 19 (11) :1075-1083
[10]  
Pouzo J., 2000, J PHYS D, VD 33, P147