Abdominal CT: Comparison of Adaptive Statistical Iterative and Filtered Back Projection Reconstruction Techniques

被引:366
作者
Singh, Sarabjeet [1 ]
Kalra, Mannudeep K. [1 ]
Hsieh, Jiang [2 ]
Licato, Paul E. [2 ]
Do, Synho [1 ]
Pien, Homer H. [1 ]
Blake, Michael A. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] GE Healthcare, Waukesha, WI USA
关键词
IMAGE QUALITY; DOSE REDUCTION; NOISE; TOMOGRAPHY; ALGORITHMS; ARTIFACTS; EMISSION; PATIENT; NUMBER;
D O I
10.1148/radiol.10092212
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare image quality and lesion conspicuity on abdominal computed tomographic (CT) images acquired with different x-ray tube current-time products (50-200 mAs) and reconstructed with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP) techniques. Materials and Methods: Twenty-two patients (mean age, 60.1 years +/- 7.3 [standard deviation]; age range, 52.8-67.4 years; mean weight, 78.9 kg +/- 18.3; 12 men, 10 women) gave informed consent for this prospective institutional review board-approved and HIPAA-compliant study, which involved the acquisition of four additional image series at multidetector CT. Images were acquired at different tube current-time products (200, 150, 100, and 50 mAs) and encompassed an abdominal lesion over a 10-cm scan length. Images were reconstructed separately with FBP and with three levels of ASIR-FBP blending. Two radiologists reviewed FBP and ASIR images for image quality in a blinded and randomized manner. Volume CT dose index (CTDIvol), dose-length product, patient weight, objective noise, and CT numbers were recorded. Data were analyzed by using analysis of variance and the Wilcoxon signed rank test. Results: CTDI vol values were 16.8, 12.6, 8.4, and 4.2 mGy for 200, 150, 100, and 50 mAs, respectively (P < .001). Subjective noise was graded as below average at 150 mAs and average at 100 and 50 mAs for ASIR images, as compared with FBP images, on which noise was graded as average at 150 mAs, above average at 100 mAs, and unacceptable at 50 mAs. A substantial blotchy image appearance was noted in four of 22 image series acquired at 4.2 mGy with 70% ASIR. Lesion conspicuity was significantly better at 4.2 mGy on ASIR than on FBP images (observed P < .044), and overall diagnostic confidence changed from unacceptable on FBP to acceptable on ASIR images. Conclusion: ASIR lowers noise and improves diagnostic confidence in and conspicuity of subtle abdominal lesions at 8.4 mGy when images are reconstructed with 30% ASIR blending and at 4.2 mGy in patients weighing 90 kg or less when images are reconstructed with 50% or 70% ASIR blending. (C) RSNA, 2010
引用
收藏
页码:373 / 383
页数:11
相关论文
共 25 条
[1]   Would thyroid and breast shielding be beneficial in CT of the head? [J].
Beaconsfield, T ;
Nicholson, R ;
Thornton, A ;
Al-Kutoubi, A .
EUROPEAN RADIOLOGY, 1998, 8 (04) :664-667
[2]  
Cohnen M, 2000, AM J NEURORADIOL, V21, P1654
[4]   Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm [J].
De Man, B ;
Nuyts, J ;
Dupont, P ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :977-981
[5]   Unenhanced helical CT using increased pitch for suspected renal colic: An effective technique for radiation dose reduction? [J].
Diel, J ;
Perlmutter, S ;
Venkataramanan, N ;
Mueller, R ;
Lane, MJ ;
Katz, DS .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (05) :795-801
[6]  
*EUR, 16262 EUR
[7]   Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[8]   Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose [J].
Hein, E ;
Rogalla, P ;
Klingebiel, R ;
Hamm, B .
EUROPEAN RADIOLOGY, 2002, 12 (07) :1693-1696
[9]   Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study [J].
Heyer, Christoph M. ;
Mohr, Patrick S. ;
Lemburg, Stefan P. ;
Peters, Soeren A. ;
Nicolas, Volkmar .
RADIOLOGY, 2007, 245 (02) :577-583
[10]   Effectivity of lead aprons to reduce the radiation dose of patient in CT. [J].
Hidajat, N ;
Schroder, RJ ;
Vogl, T ;
Schedel, H ;
Felix, R .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (05) :462-465