Thoracic aorta at multi-detector row CT: Motion artifact with various reconstruction windows

被引:23
|
作者
Morgan-Hughes, GJ
Owens, PE
Marshall, AJ
Roobottom, CA
机构
[1] Plymouth NHS Trust, SW Cardiothorac Ctr, Dept Cardiol, Plymouth PL6 8DH, Devon, England
[2] Plymouth NHS Trust, SW Cardiothorac Ctr, Dept Radiol, Plymouth PL6 8DH, Devon, England
关键词
aneurysm; dissecting; aorta; CT; computed tomography (CT); artifact; multidetector row;
D O I
10.1148/radiol.2282020873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors assessed motion artifact of the thoracic aorta in 25 patients who underwent multi-detector row computed tomography (CT) with retrospective electrocardiographic (ECG) gating. CT reconstructions centered at four phases of diastole were compared for five different levels of the thoracic aorta. A significant positive correlation was observed between heart rate and motion artifact (r = 0.72, P < .001). The optimal reconstruction phase varied between patients, and this was directly related to heart rate. For patients with a heart rate of 70 beats per minute, the reconstruction phase centered at 75% of the R-R interval had the significantly least motion artifact (P = .004). Conversely, the optimal reconstruction phase for patients with heart rates above 70 beats per minute was centered at 50% of the R-R interval (P = .09). (C) RSNA, 2003.
引用
收藏
页码:583 / 588
页数:6
相关论文
共 50 条
  • [31] Demonstration of the artery of Adamkiewicz at multi-detector row helical CT
    Takase, K
    Sawamura, Y
    Igarashi, K
    Chiba, Y
    Haba, K
    Saito, H
    Takahashi, S
    RADIOLOGY, 2002, 223 (01) : 39 - 45
  • [32] Multi-detector row CT of relevant vascular anatomy of the surgical plane in split-liver transplantation
    Guiney, MJ
    Kruskal, JB
    Sosna, J
    Hanto, DW
    Goldberg, SN
    Raptopoulos, V
    RADIOLOGY, 2003, 229 (02) : 401 - 407
  • [33] Vascular calcification in ex vivo carotid specimens: Precision and accuracy of measurements with multi-detector row CT
    Hoffmann, U
    Kwait, DC
    Handwerker, J
    Chan, R
    Lamuraglia, G
    Brady, TJ
    RADIOLOGY, 2003, 229 (02) : 375 - 381
  • [34] Abdominal aortic aneurysms at multi-detector row helical CT: Optimization with interactive determination of scanning delay and contrast medium dose
    Ho, LM
    Nelson, RC
    Thomas, J
    Gimenez, EI
    DeLong, DM
    RADIOLOGY, 2004, 232 (03) : 854 - 859
  • [35] Single versus multi-detector row CT: Comparison of radiation doses and dose profiles
    Thornton, FJ
    Paulson, EK
    Yoshizumi, TT
    Frush, DP
    Nelson, RC
    ACADEMIC RADIOLOGY, 2003, 10 (04) : 379 - 385
  • [36] Pulmonary embolism: Optimization of small pulmonary artery visualization at multi-detector row CT
    Patel, S
    Kazerooni, EA
    Cascade, PN
    RADIOLOGY, 2003, 227 (02) : 455 - 460
  • [37] Multi-detector row CT: Effect of iodine dose reduction on hepatic and vascular enhancement
    Roos, JE
    Desbiolles, LM
    Weishaupt, D
    Wildermuth, S
    Hilfiker, PR
    Marincek, B
    Boehm, T
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (04): : 556 - 563
  • [38] Superior semicircular canal dehiscence syndrome and multi-detector row CT
    Curtin, HD
    RADIOLOGY, 2003, 226 (02) : 312 - 314
  • [39] Breath-hold three-dimensional CT of the liver with multi-detector row helical CT
    Wong, K
    Paulson, EK
    Nelson, RC
    RADIOLOGY, 2001, 219 (01) : 75 - 79
  • [40] Hepatocellular carcinoma: Detection with triple-phase multi-detector row helical CT in patients with chronic hepatitis
    Laghi, A
    Iannaccone, R
    Rossi, P
    Carbone, I
    Ferrari, R
    Mangiapane, F
    Nofroni, I
    Passariello, R
    RADIOLOGY, 2003, 226 (02) : 543 - 549