Thoracic aorta at multi-detector row CT: Motion artifact with various reconstruction windows

被引:23
|
作者
Morgan-Hughes, GJ
Owens, PE
Marshall, AJ
Roobottom, CA
机构
[1] Plymouth NHS Trust, SW Cardiothorac Ctr, Dept Cardiol, Plymouth PL6 8DH, Devon, England
[2] Plymouth NHS Trust, SW Cardiothorac Ctr, Dept Radiol, Plymouth PL6 8DH, Devon, England
关键词
aneurysm; dissecting; aorta; CT; computed tomography (CT); artifact; multidetector row;
D O I
10.1148/radiol.2282020873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors assessed motion artifact of the thoracic aorta in 25 patients who underwent multi-detector row computed tomography (CT) with retrospective electrocardiographic (ECG) gating. CT reconstructions centered at four phases of diastole were compared for five different levels of the thoracic aorta. A significant positive correlation was observed between heart rate and motion artifact (r = 0.72, P < .001). The optimal reconstruction phase varied between patients, and this was directly related to heart rate. For patients with a heart rate of 70 beats per minute, the reconstruction phase centered at 75% of the R-R interval had the significantly least motion artifact (P = .004). Conversely, the optimal reconstruction phase for patients with heart rates above 70 beats per minute was centered at 50% of the R-R interval (P = .09). (C) RSNA, 2003.
引用
收藏
页码:583 / 588
页数:6
相关论文
共 50 条
  • [1] Thoracic aorta: Motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT
    Roos, JE
    Willmann, JK
    Weishaupt, D
    Lachat, M
    Marincek, B
    Hilfiker, PR
    RADIOLOGY, 2002, 222 (01) : 271 - 277
  • [2] Multi-detector row CT angiography of the brain at various kilovoltage settings
    Ertl-Wagner, BB
    Hoffmann, RT
    Bruning, R
    Herrmann, K
    Snyder, B
    Blume, JD
    Reiser, MF
    RADIOLOGY, 2004, 231 (02) : 528 - 535
  • [3] Multiplanar and three-dimensional multi-detector row CT of thoracic vessels and airways in the pediatric population
    Siegel, MJ
    RADIOLOGY, 2003, 229 (03) : 641 - 650
  • [4] Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography
    Choi, HS
    Choi, BW
    Choe, KO
    Choi, DH
    Yoo, KJ
    Kim, MI
    Kim, J
    RADIOGRAPHICS, 2004, 24 (03) : 787 - 800
  • [5] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [6] Laparoscopic splenectomy: Multi-detector row CT for preoperative evaluation
    Napoli, A
    Catalano, C
    Silecchia, G
    Fabiano, P
    Fraioli, F
    Pediconi, F
    Venditti, F
    Basso, N
    Passariello, R
    RADIOLOGY, 2004, 232 (02) : 361 - 367
  • [7] Multi-detector row CT urography in the evaluation of hematuria
    Joffe, SA
    Servaes, S
    Okon, S
    Horowitz, M
    RADIOGRAPHICS, 2003, 23 (06) : 1441 - 1455
  • [8] Multi-detector row CT: Radiation dose characteristics
    Hamberg, LM
    Rhea, JT
    Hunter, GJ
    Thrall, JH
    RADIOLOGY, 2003, 226 (03) : 762 - 772
  • [9] Multi-detector row CT of thoracic disease with emphasis on 3D volume rendering and CT angiography
    Lawler, LP
    Fishman, EK
    RADIOGRAPHICS, 2001, 21 (05) : 1257 - 1273
  • [10] Multi-detector row CT of mesenteric ischemia: Can it be done?
    Horton, KM
    Fishman, EK
    RADIOGRAPHICS, 2001, 21 (06) : 1463 - 1473