Comparison of Geant4/Gamos with Monte Carlo Multilayer: Photon Transport in Tissue-Simulating Phantom for Glucose Sensing

被引:0
|
作者
Mustafa, Fatin Hamimi [1 ]
Yi, Xiaoke [1 ]
McEwan, Alistair Lee [1 ]
机构
[1] Univ Sydney, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
来源
6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING | 2015年 / 45卷
关键词
Geant4/Gamos tissue optics; non-invasive glucose monitoring; Monte Carlo Multilayer; tissue-simulating phantom; LIGHT TRANSPORT;
D O I
10.1007/978-3-319-11128-5_69
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The comparison between a widely used Monte Carlo simulation method with a newly developed stochastic method, the Geant4/Gamos tissue optics is performed for simulating photon transport in an application of glucose sensing. The past studies show the optical properties would change with the changes of the glucose concentration. Parameter values of thickness of the tissue phantom and optical properties are taken from the previous reportedMCML method at 800nmand 960nmwith the glucose concentration in the range of 0 to 30mM. The results of total reflectance (R-d) and total transmittance (T-d) exhibit a good agreement between the Geant4/Gamos and the MCML. The sensitivity of the Geant4/Gamos was higher than that of the MCML in all measurements. At 800nm, the difference of the sensitivity between the Geant4/Gamos and the MCML were 0.024 percent/mM (transmittance) and 0.014 percent/mM (reflectance). Meanwhile, at 960nm, the difference of the sensitivity between the Geant4/Gamos with the MCML was 0.004 percent/mM in both transmittance and reflectance.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 50 条
  • [2] VERIFICATION OF A PROTON THERAPY FACILITY MONTE CARLO SIMULATION BASED ON THE GAMOS/GEANT4 FRAMEWORK
    Lagares, J. I.
    Arce, P.
    Terron, J. A.
    Nieto-Camero, J. J.
    Sansaloni, F.
    Korf, A.
    Romero Exposito, M. T.
    Nunez, L.
    Rodriguez, R.
    Loubser, M.
    Sanchez-Doblado, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S531 - S531
  • [3] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Bardane, Adil
    Tajmouaati, Jaouad
    Maghnouj, Abdelmajid
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (01) : 58 - 62
  • [4] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Adil Bardane
    Jaouad Tajmouaati
    Abdelmajid Maghnouj
    Moscow University Physics Bulletin, 2020, 75 : 58 - 62
  • [5] A GAMOS plug-in for GEANT4 based Monte Carlo simulation of radiation-induced light transport in biological media
    Glaser, Adam K.
    Kanick, Stephen C.
    Zhang, Rongxiao
    Arce, Pedro
    Pogue, Brian W.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (05): : 741 - 759
  • [6] Validation of GAMOS code based on Geant4 Monte Carlo for a 12 MV Saturne43 Linac
    Al Zain, Jamal
    El Bardouni, T.
    Mohammed, Maged
    El Hajjaji, O.
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2019, 31 (04) : 500 - 505
  • [7] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    Moscow University Physics Bulletin, 2017, 72 : 658 - 662
  • [8] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662
  • [9] INTERCOMPARISION OF MONTE CARLO RADIATION TRANSPORT CODES MCNPX, GEANT4, AND FLUKA FOR SIMULATING PROTON RADIOTHERAPY OF THE EYE
    Randeniya, S. D.
    Taddei, P. J.
    Newhauser, W. D.
    Yepes, P.
    NUCLEAR TECHNOLOGY, 2009, 168 (03) : 810 - 814
  • [10] Geant4 - A new Monte Carlo toolkit for simulating space radiation shielding and effects
    Truscott, P
    Lei, F
    Dyer, C
    Ferguson, C
    Gurriaran, R
    Nieminen, P
    Daly, E
    Apostolakis, J
    Giani, S
    Pia, MG
    Urban, L
    Maire, M
    2000 IEEE RADIATION EFFECTS DATA WORKSHOP - WORKSHOP RECORD, 2000, : 147 - 152